Skip to Content
2N

2N® Lift8

A highly modular elevator communication system, where the two-wire bus makes the 2N® Lift8 readily installable in any elevator context. This means that when it comes to providing for emergency elevator communications you won’t have to trouble with putting in new cabling. 2N® Lift8 meets all the applicable EU standards.

  • Easy installation
  • Comprehensive, modular, expandable
  • Wide range of communication interfaces
About

Features & Benefits

  • Easy installation
    Take advantage of the 2 wire communication bus for installation in the shaft. This makes for the quick and easy replacement of legacy solutions.
  • Comprehensive, modular, expandable
    You can connect up to 8 independent lift shafts to one central 2N® Lift8 unit. Each shaft can have up to 6 communication units.
  • Wide range of communication interfaces
    Choose from a wide range of communication interfaces, among PSTN/GSM/UMTS/IP. The communication interface can be changed on a modular basis, without having to replace the whole system.
  • Simple configuration
    The configuration can be done locally with the supplied configuration software application or remotely using the voice menu, software application or SMS.
  • Conference calls
    Within each of the shafts you can run a conference call between all the connected units, including the unit in the machine room.
  • Fireman communication unit
    The fireman unit serves during fire-fighter intervention. It activates a call with top priority, and allows you to establish a connection with the cabin communicator and machine room in the same lift shaft.
  • 4 versions of cabin units
    You can choose from the basic unit behind a panel, a cabled panel unit and units to install on the surface (‘Compact’ case) or flush mounted.
  • Extending modules
    The system can be extended by additional I/O modules, a camera module, or an RS232 module. In addition to audio units you can remotely monitor the status of the lift controller.
  • Up to 6 numbers for alarm calls
    2N® Lift8 allows you to specify up to 6 numbers for alarm calls, their calling sequence is based on user settings.
  • Own call centre
    The 2N® Lift8 system comes with its own application for surveillance and a call centre. You obtain a comprehensive solution including supervisory software.
Show more

Compatibility with Global Technology Partners

Get to know the wide range of technologies which are compatible with our products.

Technical parameters

Central unit
Power supply (max.) 100-240V; 50/60Hz; 0,75A; 60W
Backup power supply Internal Lead Acid Battery (1,3 Ah / 3 Ah)
Maximum distance between splitters 100 m (with cable cross-section 2,5 mm2 )
Connection options 7 reporting units +7 splitters + 8 I/O modules
Interface for connection with lift service centre Choice of PSTN/GSM/UMTS/LTE/VoIP
Configuration and monitoring: Voice menu / USB / remote
Indicators 5× LED, three-colour
Dimensions and weight: 300×170×72mm, 2.7kg
Operating temperature 0 - 40°C
Cellular network
Bands GSM 850/900/1800/1900
MHz UMTS 800/850/900/2100 MHz
LTE module (EG25-G):
LTE-FDD: B1/B2/B3/B4/B5/B7/B8/B12/ B13/B18/B19/B20/B25/B26/B28
LTE-TDD: B38/B39/B40/B41
WCDMA: B1/B2/B4/B5/B6/B8/B19
GSM: B2/B3/B5/B8
SIM card mini, plug-in 3V
Antenna one external with SMA connector
Camera module
Power supply 12 – 18V DC, max. 0,2A
Camera Interface RS232/RS485 and RJ-45
Dimensions 142 × 98 × 34 mm
Memory card microSD up to 32GB
Splitter
Power supply 24V from Central Unit or local
Capacity 7 audio units and Camera module
Max. overall length 600 m
Lift block impulse Relay, both NO and NC contacts
Dimensions 142 × 98 × 34 mm
Fireman unit & audio unit shaft (antivandal)
Cover robust aluminum casting
Operating temperature −25°C - 55°C
Operating relative humidity 10% - 95% (non-condensing)
Storage temperature −40°C - 70°C
Dimensions 217 × 109 × 83 mm, (242 × 136 × 83 mm including the frame)
Weight netto: max. 2 kg, brutto: max 2,5 kg
IP coverage IP65
I/O module
Power supply 24V from central unit or local
Capacity 4 inputs + 4 outputs
Inputs Galvanized insulation, 12 - 24V AC or DC
Outputs Relay, NO contacts, max. 250V, 5A
Dimensions 142 × 98 × 34 mm
Show more
Typical Usage

Where to Buy

You can purchase these products from our authorised distributors.
Locate a distributor
Technical area

Documents

Marketing documentation

Case Study

Example of Typical Connection

FAQ

Are you still looking for more information? Check out the frequently asked questions and answers.
See more

Licenses

Find out the detailed description of product licensing policy.
See more

Compatibility with Global Technology Partners

Get to know the wide range of technologies which are compatible with our products.

Technical parameters

Central unit
Power supply (max.) 100-240V; 50/60Hz; 0,75A; 60W
Backup power supply Internal Lead Acid Battery (1,3 Ah / 3 Ah)
Maximum distance between splitters 100 m (with cable cross-section 2,5 mm2 )
Connection options 7 reporting units +7 splitters + 8 I/O modules
Interface for connection with lift service centre Choice of PSTN/GSM/UMTS/LTE/VoIP
Configuration and monitoring: Voice menu / USB / remote
Indicators 5× LED, three-colour
Dimensions and weight: 300×170×72mm, 2.7kg
Operating temperature 0 - 40°C
Cellular network
Bands GSM 850/900/1800/1900
MHz UMTS 800/850/900/2100 MHz
LTE module (EG25-G):
LTE-FDD: B1/B2/B3/B4/B5/B7/B8/B12/ B13/B18/B19/B20/B25/B26/B28
LTE-TDD: B38/B39/B40/B41
WCDMA: B1/B2/B4/B5/B6/B8/B19
GSM: B2/B3/B5/B8
SIM card mini, plug-in 3V
Antenna one external with SMA connector
Camera module
Power supply 12 – 18V DC, max. 0,2A
Camera Interface RS232/RS485 and RJ-45
Dimensions 142 × 98 × 34 mm
Memory card microSD up to 32GB
Splitter
Power supply 24V from Central Unit or local
Capacity 7 audio units and Camera module
Max. overall length 600 m
Lift block impulse Relay, both NO and NC contacts
Dimensions 142 × 98 × 34 mm
Fireman unit & audio unit shaft (antivandal)
Cover robust aluminum casting
Operating temperature −25°C - 55°C
Operating relative humidity 10% - 95% (non-condensing)
Storage temperature −40°C - 70°C
Dimensions 217 × 109 × 83 mm, (242 × 136 × 83 mm including the frame)
Weight netto: max. 2 kg, brutto: max 2,5 kg
IP coverage IP65
I/O module
Power supply 24V from central unit or local
Capacity 4 inputs + 4 outputs
Inputs Galvanized insulation, 12 - 24V AC or DC
Outputs Relay, NO contacts, max. 250V, 5A
Dimensions 142 × 98 × 34 mm
Show more

Register for Technical Training

View our technical training courses. Choose the one that suits you best.
See more
Accessories

Audio Units

2N® Lift8 - Central Unit Order No.: 918600E Learn more
2N® Lift8 - Audio Unit COP Order No.: 918610E Learn more
2N® Lift8 - Audio Unit Machine room Order No.: 918611E Learn more
2N® Lift8 - Audio Unit Shaft Order No.: 918612E Learn more
2N® Lift8 - Audio Unit Compact, With button Order No.: 918613E Learn more
2N® Lift8 - Audio Unit Compact, Without button Order No.: 918613WBE Learn more
2N® Lift8 - Audio Unit Fireman, Key Order No.: 918615E Learn more
2N® Lift8 - Antivandal Cabin Plate Order No.: 918616E Learn more
2N® Lift8 - Audio Unit Flush, Without button Order No.: 918618E Learn more
2N® LiftIP 2.0 Voice Alarm Station Set Order No.: 921661SET Learn more
2N® Lift8 - Audio Unit COP, Cable version Order No.: 918610XE Learn more
2N® Lift8 - Audio Unit Flush, With button Order No.: 918618E Learn more
2N® Lift8 IP Order No.: 918655E Learn more

Central Unit Modules

2N® Lift8 - GSM Module Order No.: 918650E Learn more
2N® Lift8 - UMTS Module Order No.: 918651E Learn more
2N® Lift8 - PSTN Module Order No.: 918652E Learn more
2N® Lift8 - VoIP Module Order No.: 918653E Learn more
2N® Lift8 - RS232 Module Order No.: 918654E Learn more

Extending Modules

2N® Lift8 - Splitter Order No.: 918620E Learn more
2N® Lift8 - I/O Module Order No.: 918621E Learn more
2N® Lift8 - Camera Module Order No.: 918622E Learn more
2N® Lift Induction Loop Amplifier, 1 Audio Input Order No.: 919621E Learn more
2N® Lift Induction Loop Amplifier, 2 Audio Inputs Order No.: 919622E Learn more
2N® Floor Announciator Order No.: 913305 Learn more
Sales Area

Selling Propositions

  • Easy installation
    Take advantage of the 2 wire communication bus for installation in the shaft. This makes for the quick and easy replacement of legacy solutions.
  • Comprehensive, modular, expandable
    You can connect up to 8 independent lift shafts to one central 2N® Lift8 unit. Each shaft can have up to 6 communication units.
  • Wide range of communication interfaces
    Choose from a wide range of communication interfaces, among PSTN/GSM/UMTS/IP. The communication interface can be changed on a modular basis, without having to replace the whole system.
  • Simple configuration
    The configuration can be done locally with the supplied configuration software application or remotely using the voice menu, software application or SMS.
  • Conference calls
    Within each of the shafts you can run a conference call between all the connected units, including the unit in the machine room.
  • Fireman communication unit
    The fireman unit serves during fire-fighter intervention. It activates a call with top priority, and allows you to establish a connection with the cabin communicator and machine room in the same lift shaft.
  • 4 versions of cabin units
    You can choose from the basic unit behind a panel, a cabled panel unit and units to install on the surface (‘Compact’ case) or flush mounted.
  • Extending modules
    The system can be extended by additional I/O modules, a camera module, or an RS232 module. In addition to audio units you can remotely monitor the status of the lift controller.
  • Up to 6 numbers for alarm calls
    2N® Lift8 allows you to specify up to 6 numbers for alarm calls, their calling sequence is based on user settings.
  • Own call centre
    The 2N® Lift8 system comes with its own application for surveillance and a call centre. You obtain a comprehensive solution including supervisory software.
Show more

Compatibility with Global Technology Partners

Get to know the wide range of technologies which are compatible with our products.

Related Norms and Certificates

The quality of our products is crucial to us and our customers, which is why they fully comply with strict European Union standards.

Where to Sell

Take a look at the solutions where this product can be used.
Residential - Single House
Residential - Apartment Building
Commercial & Corporate Sector

Technical parameters

Central unit
Power supply (max.) 100-240V; 50/60Hz; 0,75A; 60W
Backup power supply Internal Lead Acid Battery (1,3 Ah / 3 Ah)
Maximum distance between splitters 100 m (with cable cross-section 2,5 mm2 )
Connection options 7 reporting units +7 splitters + 8 I/O modules
Interface for connection with lift service centre Choice of PSTN/GSM/UMTS/LTE/VoIP
Configuration and monitoring: Voice menu / USB / remote
Indicators 5× LED, three-colour
Dimensions and weight: 300×170×72mm, 2.7kg
Operating temperature 0 - 40°C
Cellular network
Bands GSM 850/900/1800/1900
MHz UMTS 800/850/900/2100 MHz
LTE module (EG25-G):
LTE-FDD: B1/B2/B3/B4/B5/B7/B8/B12/ B13/B18/B19/B20/B25/B26/B28
LTE-TDD: B38/B39/B40/B41
WCDMA: B1/B2/B4/B5/B6/B8/B19
GSM: B2/B3/B5/B8
SIM card mini, plug-in 3V
Antenna one external with SMA connector
Camera module
Power supply 12 – 18V DC, max. 0,2A
Camera Interface RS232/RS485 and RJ-45
Dimensions 142 × 98 × 34 mm
Memory card microSD up to 32GB
Splitter
Power supply 24V from Central Unit or local
Capacity 7 audio units and Camera module
Max. overall length 600 m
Lift block impulse Relay, both NO and NC contacts
Dimensions 142 × 98 × 34 mm
Fireman unit & audio unit shaft (antivandal)
Cover robust aluminum casting
Operating temperature −25°C - 55°C
Operating relative humidity 10% - 95% (non-condensing)
Storage temperature −40°C - 70°C
Dimensions 217 × 109 × 83 mm, (242 × 136 × 83 mm including the frame)
Weight netto: max. 2 kg, brutto: max 2,5 kg
IP coverage IP65
I/O module
Power supply 24V from central unit or local
Capacity 4 inputs + 4 outputs
Inputs Galvanized insulation, 12 - 24V AC or DC
Outputs Relay, NO contacts, max. 250V, 5A
Dimensions 142 × 98 × 34 mm
Show more

Documents

Marketing documentation
Request information