| Date | Name | Category | Size | Type | Download |
|---|---|---|---|---|---|
| 15.03.2013 | VOIP/PRI gateway 2N® BlueTower - Product leaflet (EN) | Leaflet | 3.12 MB | ||
| 15.03.2013 | Digital & VoIP gateway 2N® BlueTower - Configuration tool 2.16.16 (EN) | Software | 814.23 kB | ZIP | |
| 15.03.2013 | Digital & VoIP gateways 2N® StarGate & BlueTower - Configuration tool 2.0i (EN) | Software | 1.41 MB | ZIP | |
| 01.03.2013 | VOIP/PRI/GSM/UMTS gateways 2N® StarGate & BlueTower - Firmware 2.30.13 (EN) | Firmware | 254.88 kB | ZIP | |
| 01.03.2013 | VOIP/PRI/GSM/UMTS gateways 2N® StarGate & BlueTower - Firmware 2.20.51 (EN) | Firmware | 237.92 kB | ZIP | |
| 01.03.2013 | VOIP/PRI/GSM/UMTS gateways 2N® StarGate & BlueTower - Firmware 2.17.12 (EN) | Firmware | 186.08 kB | ZIP | |
| 15.03.2013 | Digital & VoIP gateway 2N® BlueTower - Manual (EN) | Manual | 5.22 MB | ||
| 15.03.2013 | GSM/VOIP gateways 2N® StarGate & BlueTower - Interconnection guide with Siemens HiPath (EN) | How to | 325.88 kB | ||
| 15.03.2013 | GSM/VOIP gateways 2N® StarGate & BlueTower - Interconnection guide with Alcatel OXO (EN) | How to | 405.57 kB |
2N® BlueTower VoIP
| Date | Name | Category | Size | Type | Download |
|---|---|---|---|---|---|
| 15.03.2013 | VOIP/PRI gateway 2N® BlueTower - Product leaflet (EN) | Leaflet | 3.12 MB | ||
| 15.03.2013 | Digital & VoIP gateway 2N® StarGate - Configuration tool 2.0i (EN) | Software | 1.41 MB | ZIP | |
| 01.03.2013 | VOIP/PRI/GSM/UMTS gateways 2N® StarGate & BlueTower - Firmware 2.30.13 (EN) | Firmware | 254.88 kB | ZIP | |
| 15.03.2013 | Digital & VoIP gateway 2N® StarGate - Manual (EN) | Manual | 5.22 MB | ||
| 15.03.2013 | GSM/VOIP gateways 2N® StarGate & BlueTower - Interconnection guide with Alcatel OXO (EN) | How to | 405.57 kB |
2N® BRI Enterprise
2N® BRI Lite
2N® EasyGate
| Date | Name | Category | Size | Type | Download |
|---|---|---|---|---|---|
| 28.01.2013 | Analogue GSM gateway 2N® EasyGate, 2N® SmartGate - Product leaflet (EN) | Leaflet | 330.92 kB | ||
| 28.01.2013 | Certificate for 2N® EasyGate - Declaration of Conformity (EN) | Certificate | 93.11 kB | ||
| 02.04.2013 | GSM Gateway 2N® EasyGate GSM/UMTS modem driver v1.7 | Software | 256 B | ZIP | |
| 12.04.2013 | Calling cost with 2N® EasyGate - PC Manager v1.28, FW2.20.1 | Firmware | 1.18 MB | ZIP | |
| 22.01.2013 | Analogue GSM gateway 2N® EasyGate - Manual (EN), 1575 v1.1.0.2 | Manual | 944.33 kB | ||
| 23.01.2013 | Fixed line replacement with 2N® EasyGate - Quick Start (EN), 1129 v1.5E | Manual | 534.51 kB | ||
| 28.01.2013 | How to set up Baby Call in 2N® EasyGate (EN) | How to | 131.44 kB |
2N® EasyGate PRO
| Date | Name | Category | Size | Type | Download |
|---|---|---|---|---|---|
| 28.01.2013 | Analogue GSM gateway 2N® EasyGate PRO - Leaflet (EN) | Leaflet | 1.97 MB | ||
| 28.01.2013 | Certificate for 2N® EasyGate PRO - EC Declaration of Conformity (EN) | Certificate | 146.80 kB | ||
| 02.04.2013 | PCManagerUNI208 X_6_6 - Universal programming tool | Software | 1.01 MB | ZIP | |
| 02.04.2013 | GSM Gateway 2N® EasyGate GSM/UMTS modem driver v1.7 | Software | 256 B | ZIP | |
| 21.01.2013 | Driver for USB (FTDI) | Software | 1.65 MB | EXE | |
| 23.01.2013 | Fixed line replacement with 2N® EasyGate PRO - Quick Start (EN) | Manual | 388.00 kB | ||
| 23.01.2013 | Analogue GSM gateway 2N® EasyGate PRO - Manual (EN) | Manual | 1.50 MB |
2N® EasyGate UMTS USB
2N® EasyRoute
2N® External Routing Machine
| Date | Name | Category | Size | Type | Download |
|---|---|---|---|---|---|
| 01.03.2013 | Call Managing Software 2N® External Routing Machine - Manual (EN) | Manual | 5.22 MB |
2N® Helios
2N® Helios Force
| Date | Name | Category | Size | Type | Download |
|---|---|---|---|---|---|
| 14.03.2013 | Weather-proof Intercom 2N® Helios Force - Product Leaftlet (EN) | Leaflet | 1.69 MB | ||
| 16.04.2013 | Analog Intercom 2N® Helios Force and Safety - Installation manual (EN) | Manual | 1.96 MB |
2N® Helios IP
| Date | Name | Category | Size | Type | Download |
|---|---|---|---|---|---|
| 18.05.2011 | 2N® Helios IP - Product leaflet | Leaflet | 3.05 MB | ||
| 24.01.2011 | 2N Helios IP interoperability | Leaflet | 254.24 kB | ||
| 19.11.2010 | 2N Helios IP_Declaration of Conformity | Certificate | 91.48 kB | ||
| 18.06.2010 | 2N Helios IP - Cisco Compatibility Certificate | Certificate | 98.23 kB | ||
| 02.12.2011 | 2N® Helios IP EYE 1.0.0.6 | Software | 26.77 MB | EXE | |
| 29.03.2011 | 2N® Helios IP Configuration tool version 1.12 | Software | 30.88 MB | ZIP | |
| 07.12.2010 | 2N® Helios IP Configuration tool version 1.11 | Software | 4.53 MB | ZIP | |
| 20.11.2011 | 2N® Helios IP Firmware version 1.13 | Firmware | 4.47 MB | BIN | |
| 30.03.2011 | 2N® Helios IP Firmware version 1.12 | Firmware | 4.02 MB | BIN | |
| 07.12.2010 | 2N® Helios IP Firmware version 1.11 | Firmware | 3.90 MB | BIN | |
| 20.11.2011 | 2N® Helios IP User manual version 1.13 | Manual | 4.41 MB | ||
| 29.03.2011 | 2N® Helios IP User manual version 1.12 | Manual | 4.14 MB | ||
| 07.12.2010 | 2N® Helios IP User manual version 1.11 | Manual | 3.83 MB | ||
| 01.12.2010 | How to connect 2N Helios IP via SIP trunk to CCM | How to | 191.48 kB | ||
| 01.12.2010 | How to connect 2N Helios IP to CCME 4 | How to | 270.89 kB | ||
| 01.12.2010 | How to connect 2N Helios IP as an extension to CCM 6 and 7 | How to | 218.24 kB | ||
| 01.12.2010 | How to make direct IP call from 2N Helios IP | How to | 109.58 kB | ||
| 01.12.2010 | How to connect 2N Helios IP to Alcatel OXO | How to | 362.99 kB | ||
| 01.12.2010 | How to set up2N Helios IP with Grandstream 3140 | How to | 650.03 kB | ||
| 05.10.2010 | incomming call please pres the asterisk button.wav | Other | 24.98 kB | WAV | |
| 05.10.2010 | invalid possition please dial again.wav | Other | 22.30 kB | WAV | |
| 05.10.2010 | the door is open please com in.wav | Other | 37.19 kB | WAV | |
| 05.10.2010 | invalid number please dial again.wav | Other | 20.62 kB | WAV |
2N® Helios IP Audio Kit
| Date | Name | Category | Size | Type | Download |
|---|---|---|---|---|---|
| 24.01.2013 | Parking phone system 2N® Helios IP Audio Kit - Product leaflet (EN) | Leaflet | 566.63 kB | ||
| 24.01.2013 | Intercom software 2N® Helios IP Network Scanner 2.0.0 (EN) | Software | 43.78 MB | EXE | |
| 16.05.2013 | 2N® Helios IP Audio Kit - Firmware v2.3.2 | Firmware | 3.53 MB | BIN | |
| 25.03.2013 | 2N® Helios IP Audio Kit - Firmware v2.3.0 | Firmware | 3.53 MB | BIN | |
| 23.03.2013 | 2N® Helios IP Audio Kit - Installation manual version 1.0.2 (EN) | Manual | 1000.01 kB | ||
| 23.03.2013 | Home intercom 2N® Helios IP - Configuration manual version 2.3.0 (EN) | Manual | 3.14 MB | ||
| 23.03.2013 | Home intercom 2N® Helios IP - Automation manual version 2.3.0 (EN) | Manual | 675.22 kB | ||
| 15.03.2013 | 2N® Helios IP Audio Kit - Installation manual | Manual | 999.13 kB |
2N® Helios IP Force
2N® Helios IP Safety
2N® Helios IP Uni
2N® Helios IP Vario
2N® Helios IP Video Kit
| Date | Name | Category | Size | Type | Download |
|---|---|---|---|---|---|
| 10.04.2013 | Video phone system 2N® Helios IP Video Kit - Product leaflet (EN) | Leaflet | 1.33 MB | ||
| 16.05.2013 | 2N® Helios IP Video Kit - Firmware v2.3.2 | Firmware | 5.01 MB | BIN | |
| 25.03.2013 | 2N® Helios IP Video Kit - Firmware v2.3.0 | Firmware | 5.01 MB | BIN | |
| 23.03.2013 | 2N® Helios IP Video Kit - Installation manual version 1.0.0 (EN) | Manual | 976.88 kB | ||
| 23.03.2013 | Home intercom 2N® Helios IP - Configuration manual version 2.3.0 (EN) | Manual | 3.14 MB | ||
| 23.03.2013 | Home intercom 2N® Helios IP - Automation manual version 2.3.0 (EN) | Manual | 675.22 kB |
2N® Helios Safety
| Date | Name | Category | Size | Type | Download |
|---|---|---|---|---|---|
| 14.03.2013 | Emergency intercom 2N® Helios Safety - Product leaflet (EN) | Leaflet | 1.22 MB | ||
| 16.04.2013 | Analog Intercom 2N® Helios Force and Safety - Installation manual (EN) | Manual | 1.96 MB |
2N® Helios Uni
| Date | Name | Category | Size | Type | Download |
|---|---|---|---|---|---|
| 21.01.2013 | Home intercom 2N® Helios UNI - Manual (EN) 1837 | Manual | 1.13 MB |
2N® LiftNet
| Date | Name | Category | Size | Type | Download |
|---|---|---|---|---|---|
| 28.01.2013 | Lift solution 2N® LiftNet - Description (EN) | Leaflet | 66.45 kB | ||
| 28.01.2013 | Lift intercom 2N® LiftNet - Leaflet (EN) | Leaflet | 646.53 kB | ||
| 28.01.2013 | Certificate for 2N® LiftNet - TUV certificate (EN) | Certificate | 722.69 kB | ||
| 22.01.2013 | Emergency phone 2N® LiftNet - USB driver | Software | 818.59 kB | ZIP | |
| 23.01.2013 | Communication solutions for lifts with 2N® LiftNet - ServiceTool 2.3.4 FW1.9.1 (CZ, SK, EN, DE) | Software | 88.13 MB | ZIP | |
| 22.01.2013 | Lift emergency phone 2N® LiftNet - Manual (EN), version 1.8.3 | Manual | 2.77 MB |
2N® NetSpeaker
| Date | Name | Category | Size | Type | Download |
|---|---|---|---|---|---|
| 23.04.2013 | IP public address system 2N® NetSpeaker - Product leaflet (EN) | Leaflet | 4.42 MB | ||
| 15.03.2013 | IP audio distribution system 2N® NetSpeaker - Presentation (EN) | Presentation | 3.15 MB | PPT | |
| 06.05.2013 | 2N® NetSpeaker - Software Package 1.3.9 (EN) | Software | 140.02 MB | ZIP | |
| 06.05.2013 | 2N® NetSpeaker Software Package ver. 1.3.6 | Software | 129.44 MB | ZIP | |
| 06.05.2013 | 2N® NetSpeaker Software Package ver. 1.2.5 | Software | 97.77 MB | ZIP | |
| 24.04.2013 | IP audio system 2N® NetSpeaker - QuickStart manual for sw version 1.3.x (EN) | Manual | 1.25 MB | ||
| 24.04.2013 | IP audio system 2N® NetSpeaker - Manual for sw version 1.3.x (EN) | Manual | 4.82 MB | ||
| 15.03.2013 | IP audio distribution system 2N® NetSpeaker - User Manual version 1.2.5 (EN) | Manual | 4.37 MB | ||
| 15.03.2013 | IP public address system 2N® NetSpeaker - Quick Start version 1.2.5 (EN) | Manual | 800.22 kB |
2N® NetStar
2N® NetStar IP
2N® OfficeRoute
| Date | Name | Category | Size | Type | Download |
|---|---|---|---|---|---|
| 25.01.2011 | 2N® OfficeRoute - GSM gateway - case study - leaflet | Leaflet | 1.33 MB | ||
| 03.03.2011 | 2N® OfficeRoute - product leaflet | Leaflet | 319.63 kB | ||
| 22.03.2010 | 2N® OfficeRoute - 3G Mobile office - case study - leaflet | Leaflet | 1.47 MB | ||
| 25.01.2011 | 2N® OfficeRoute - Testing stations for operators - case study - leaflet | Leaflet | 1.85 MB | ||
| 27.01.2011 | 2N® OfficeRoute - case study - IP PBX | Presentation | 1.81 MB | PPTX | |
| 27.01.2011 | 2N® OfficeRoute - case study - IP PBX | Presentation | 1.02 MB | ||
| 22.03.2010 | 2N® OfficeRoute - 3G Mobile office - case study | Presentation | 903.45 kB | ||
| 22.03.2010 | 2N® OfficeRoute - 3G Mobile office - case study | Presentation | 1.29 MB | PPT | |
| 22.03.2010 | 2N® OfficeRoute - Testing stations for operators - case study | Presentation | 633.05 kB | ||
| 22.03.2010 | 2N® OfficeRoute - Testing stations for operators - case study | Presentation | 1005.00 kB | PPT | |
| 27.01.2011 | 2N® IVR Editor v.1.0 | Software | 3.60 MB | ZIP | |
| 27.01.2011 | 2N® OfficeRoute USB Driver for MS Windows | Software | 973 B | ZIP | |
| 18.03.2013 | VoIP/GSM/UMTS gateway 2N® OfficeRoute - Firmware 2.3.20 (EN) | Firmware | 10.75 MB | ||
| 11.02.2013 | 2N® OfficeRoute - Firmware 2.3.19 | Firmware | 10.74 MB | ||
| 31.01.2012 | 2N® OfficeRoute - Firmware 2.3.18 | Firmware | 10.74 MB | ||
| 23.12.2011 | 2N® OfficeRoute - Firmware 2.3.17 | Firmware | 10.74 MB | ||
| 09.10.2011 | 2N® OfficeRoute - User manual 1.8.2 | Manual | 4.19 MB | ||
| 28.02.2011 | 2N® IVR Editor manual 1.0.2 | Manual | 1.60 MB | ||
| 27.01.2011 | How to create LCR in 2N® OfficeRoute | How to | 375.15 kB | ||
| 27.01.2011 | How to set up Voice mail in 2N® OfficeRoute | How to | 86.10 kB | ||
| 27.01.2011 | How to use Normalization in LCR in 2N® OfficeRoute | How to | 239.36 kB | ||
| 27.01.2011 | How to set up Mobility Extension in 2N® OfficeRoute | How to | 1.47 MB | ||
| 27.01.2011 | How to set up FAX in 2N® OfficeRoute | How to | 656.69 kB | ||
| 27.01.2011 | How to create IVR in 2N® OfficeRoute | How to | 573.87 kB | ||
| 27.01.2011 | How to use SMS to Email with Mozilla Thunderbird in 2N® OfficeRoute | How to | 453.67 kB | ||
| 27.01.2011 | How to Install 2N® OfficeRoute with Siemens HiPath | How to | 1.88 MB | ||
| 27.01.2011 | How to Install 2N® OfficeRoute with Alcatel OXO | How to | 1.64 MB |
2N® Omega 48
| Date | Name | Category | Size | Type | Download |
|---|---|---|---|---|---|
| 22.03.2010 | 2N® Omega Series - Product leaflet | Leaflet | 1.95 MB | ||
| 22.03.2010 | 2N® Omega 48 - Case Study | Leaflet | 2.37 MB | ||
| 22.03.2010 | 2N® Omega series - UMTS leaflet | Leaflet | 623.50 kB | ||
| 22.03.2010 | 2N® Omega series - overview leaflet | Leaflet | 1.18 MB | ||
| 26.07.2010 | Omega 48-Declaration of Conformity | Certificate | 88.55 kB | ||
| 26.09.2011 | CT 4.11 | Software | 6.28 MB | ZIP | |
| 26.09.2011 | Panel 4.11 | Software | 1.13 MB | ZIP | |
| 01.02.2011 | PBX Assistant 1.05K | Software | 10.39 MB | ZIP | |
| 01.02.2011 | CT 4.10E | Software | 6.18 MB | ZIP | |
| 27.01.2011 | 2N® IVR Editor v.1.0 | Software | 3.60 MB | ZIP | |
| 23.09.2010 | KN 4.10 | Software | 5.52 MB | ZIP | |
| 17.07.2010 | CT 4.08D - Configuration Tool | Software | 5.49 MB | ZIP | |
| 10.05.2010 | CT 4.08C | Software | 5.49 MB | ZIP | |
| 10.05.2010 | CT 4.07H | Software | 5.44 MB | ZIP | |
| 10.05.2010 | CT 4.06V | Software | 5.35 MB | ZIP | |
| 14.04.2010 | CT 4.07G - Configuration Tool | Software | 5.27 MB | ZIP | |
| 14.04.2010 | CT 4.06U - Configuration Tool | Software | 5.19 MB | ZIP | |
| 14.04.2010 | CT 4.05Y - Configuration Tool | Software | 4.82 MB | ZIP | |
| 22.03.2010 | CT 4.06S - Configuration Tool | Software | 5.18 MB | ZIP | |
| 22.03.2010 | CT 4.07D - Configuration Tool | Software | 5.26 MB | ZIP | |
| 26.09.2011 | FW 4.11rev4-DE | Firmware | 115.10 kB | ZIP | |
| 26.09.2011 | FW 4.11rev4-EN | Firmware | 114.93 kB | ZIP | |
| 12.03.2011 | FW 4.10rev6-EN | Firmware | 114.24 kB | ZIP | |
| 12.03.2011 | FW 4.10rev6-DE | Firmware | 114.41 kB | ZIP | |
| 12.11.2010 | OLI-2-3-11 - ethernet-modul-firmware | Firmware | 11.11 MB | ZIP | |
| 24.09.2010 | OLI-2-3-10 - ethernet-modul-firmware | Firmware | 11.11 MB | ZIP | |
| 23.09.2010 | FW 4.10rev2-DE | Firmware | 113.90 kB | ZIP | |
| 23.09.2010 | FW 4.10rev2-EN | Firmware | 113.73 kB | ZIP | |
| 26.07.2010 | FW 4.08rev10-DE | Firmware | 110.99 kB | ZIP | |
| 26.07.2010 | FW 4.08rev10-EN | Firmware | 110.83 kB | ZIP | |
| 17.07.2010 | FW 4.08rev8-DE | Firmware | 110.83 kB | ZIP | |
| 17.07.2010 | FW 4.08rev8-EN | Firmware | 110.68 kB | ZIP | |
| 20.05.2010 | VoiceMail System - language packs | Firmware | 2.11 MB | ZIP | |
| 20.07.2010 | OLI-2-3-7 - ethernet-modul-firmware | Firmware | 11.04 MB | ZIP | |
| 10.05.2010 | FW 4.08rev5-EN | Firmware | 110.28 kB | ZIP | |
| 10.05.2010 | FW 4.08rev5-DE | Firmware | 110.42 kB | ZIP | |
| 22.03.2010 | FW 4.06rev25-EN - the latest release of firmware version 4.06 (English) | Firmware | 105.98 kB | ZIP | |
| 22.03.2010 | FW 4.07rev9-EN - the latest release of firmware version 4.07 (English) | Firmware | 108.05 kB | ZIP | |
| 22.03.2010 | OLI-2-3-6 - ethernet-modul-firmware | Firmware | 10.94 MB | ZIP | |
| 02.02.2011 | 2N® Omega Lite PBX Assistant - manual ver. 1.2 | Manual | 1.43 MB | ||
| 01.02.2011 | 2N® Omega series - Configuration Tool manual ver. 1.10 | Manual | 1.23 MB | ||
| 01.12.2010 | 2N® IVR Editor manual EN 1.0 | Manual | 1.44 MB | ||
| 23.09.2010 | 2N® Omega series - Configuration Tool manual ver. 1.9 | Manual | 1.61 MB | ||
| 19.05.2010 | 2N® Omega series - VoIP manual ver. 1.4 | Manual | 3.89 MB | ||
| 22.03.2010 | 2N® Omega 48 - Basic Services | Manual | 1.24 MB | ||
| 22.03.2010 | 2N® Omega 48 - Installation Manual | Manual | 1.24 MB | ||
| 22.03.2010 | 2N® Omega 48 - Operator Services | Manual | 908.14 kB | ||
| 22.03.2010 | 2N® Omega 48 - Quick Guide | Manual | 224.35 kB | ||
| 22.03.2010 | 2N® StarPoint 500 - manual | Manual | 818.10 kB | ||
| 22.03.2010 | 2N® Omega Lite - Configuration Tool manual | Manual | 1.25 MB | ||
| 22.03.2010 | 2N® Omega Series - Voicemail | Manual | 807.04 kB |
2N® Omega 48 UMTS
| Date | Name | Category | Size | Type | Download |
|---|---|---|---|---|---|
| 22.03.2010 | 2N® Omega Series - Product leaflet | Leaflet | 1.95 MB | ||
| 22.03.2010 | 2N® Omega 48 - Case Study | Leaflet | 2.37 MB | ||
| 22.03.2010 | 2N® Omega Series UMTS - Product leaflet | Leaflet | 623.50 kB | ||
| 22.03.2010 | 2N® Omega series - overview leaflet | Leaflet | 1.18 MB | ||
| 26.07.2010 | Omega 48-Declaration of Conformity | Certificate | 88.55 kB | ||
| 27.01.2011 | 2N® IVR Editor v.1.0 | Software | 3.60 MB | ZIP | |
| 10.05.2010 | CT 4.08C | Software | 5.49 MB | ZIP | |
| 10.05.2010 | CT 4.07H | Software | 5.44 MB | ZIP | |
| 10.05.2010 | CT 4.06V | Software | 5.35 MB | ZIP | |
| 14.04.2010 | CT 4.05Y - Configuration Tool | Software | 4.82 MB | ZIP | |
| 20.07.2010 | OLI-2-3-7 - ethernet-modul-firmware | Firmware | 11.04 MB | ZIP | |
| 10.05.2010 | FW 4.08rev5-EN | Firmware | 110.28 kB | ZIP | |
| 10.05.2010 | FW 4.08rev5-DE | Firmware | 110.42 kB | ZIP | |
| 22.03.2010 | FW 4.06rev25-EN - the latest release of firmware version 4.06 (English) | Firmware | 105.98 kB | ZIP | |
| 22.03.2010 | FW 4.07rev9-EN - the latest release of firmware version 4.07 (English) | Firmware | 108.05 kB | ZIP | |
| 22.03.2010 | OLI-2-3-6 - ethernet-modul-firmware | Firmware | 10.94 MB | ZIP | |
| 01.12.2010 | 2N® IVR Editor manual EN 1.0 | Manual | 1.44 MB | ||
| 19.05.2010 | 2N® Omega series - VoIP manual ver. 1.4 | Manual | 3.89 MB | ||
| 22.03.2010 | 2N® Omega 48 - Basic Services | Manual | 1.24 MB | ||
| 22.03.2010 | 2N® Omega 48 - Installation Manual | Manual | 1.24 MB | ||
| 22.03.2010 | 2N® Omega 48 - Operator Services | Manual | 908.14 kB | ||
| 22.03.2010 | 2N® Omega 48 - Quick Guide | Manual | 224.35 kB | ||
| 22.03.2010 | 2N® StarPoint 500 - manual | Manual | 818.10 kB | ||
| 22.03.2010 | 2N® Omega Lite - Configuration Tool manual | Manual | 1.25 MB | ||
| 22.03.2010 | 2N® Omega Series - Voicemail | Manual | 807.04 kB |
2N® Omega Lite
| Date | Name | Category | Size | Type | Download |
|---|---|---|---|---|---|
| 22.03.2010 | 2N® Omega Series - Product leaflet | Leaflet | 1.95 MB | ||
| 22.03.2010 | 2N® Omega 48 - Case Study | Leaflet | 2.37 MB | ||
| 22.03.2010 | 2N® Omega series - UMTS leaflet | Leaflet | 623.50 kB | ||
| 22.03.2010 | 2N® Omega series - overview leaflet | Leaflet | 1.18 MB | ||
| 22.03.2010 | 2N® Omega Lite - Declaration of Conformity | Certificate | 81.99 kB | ||
| 16.03.2012 | CT 4.11A | Software | 6.28 MB | ZIP | |
| 27.09.2011 | Tone generator 1.40 | Software | 12.67 kB | HEX | |
| 27.09.2011 | PBX Assistant 1.05L | Software | 10.39 MB | ZIP | |
| 26.09.2011 | Panel 4.11 | Software | 1.13 MB | ZIP | |
| 26.09.2011 | CT 4.11 | Software | 6.28 MB | ZIP | |
| 01.02.2011 | PBX Assistant 1.05K | Software | 10.39 MB | ZIP | |
| 01.02.2011 | CT 4.10E | Software | 6.18 MB | ZIP | |
| 27.01.2011 | 2N® IVR Editor v.1.0 | Software | 3.60 MB | ZIP | |
| 23.09.2010 | CT 4.10 | Software | 5.52 MB | ZIP | |
| 04.06.2010 | PBX Assistant 1.03C | Software | 7.19 MB | ZIP | |
| 30.05.2010 | CT 4.08D | Software | 5.49 MB | ZIP | |
| 09.05.2010 | CT 4.06V | Software | 5.35 MB | ZIP | |
| 09.05.2010 | CT 4.07H | Software | 5.44 MB | ZIP | |
| 14.04.2010 | CT 4.05Y - Configuration Tool | Software | 4.82 MB | ZIP | |
| 22.03.2010 | Ethernet modul USB driver | Software | 1.01 kB | ZIP | |
| 22.03.2010 | Monitoring software for the PBX operator (firmware version 4.07) | Software | 1013.06 kB | ZIP | |
| 22.03.2010 | Monitoring software for the PBX operator (firmware version 4.06) | Software | 1013.03 kB | ZIP | |
| 22.03.2010 | 2N® Omega Lite PBX Assistant 1.02H | Software | 7.01 MB | ZIP | |
| 22.03.2010 | TSP driver 1.8 | Software | 3.63 MB | ZIP | |
| 02.01.2012 | OLI-2-3-17 - ethernet-modul-firmware | Firmware | 11.17 MB | ZIP | |
| 10.10.2011 | OLI-2-3-16 - ethernet-modul-firmware | Firmware | 11.17 MB | ZIP | |
| 27.09.2011 | GSM Module firmware 2.22 | Firmware | 186.10 kB | ZIP | |
| 26.09.2011 | FW 4.11rev4-DE | Firmware | 115.09 kB | ZIP | |
| 26.09.2011 | FW 4.11rev4-EN | Firmware | 114.93 kB | ZIP | |
| 01.02.2011 | FW 4.10rev6-EN | Firmware | 114.24 kB | ZIP | |
| 01.02.2011 | FW 4.10rev6-DE | Firmware | 114.40 kB | ZIP | |
| 12.11.2010 | OLI-2-3-11 - ethernet-modul-firmware | Firmware | 11.11 MB | ZIP | |
| 24.09.2010 | OLI-2-3-10 - ethernet-modul-firmware | Firmware | 11.11 MB | ZIP | |
| 23.09.2010 | FW 4.10rev2-DE | Firmware | 113.89 kB | ZIP | |
| 23.09.2010 | FW 4.10rev2-EN | Firmware | 113.73 kB | ZIP | |
| 26.07.2010 | FW 4.08rev10-EN | Firmware | 110.83 kB | ZIP | |
| 26.07.2010 | FW 4.08rev10-DE | Firmware | 110.98 kB | ZIP | |
| 17.07.2010 | FW 4.08rev8-DE | Firmware | 110.83 kB | ZIP | |
| 17.07.2010 | FW 4.08rev8-EN | Firmware | 110.68 kB | ZIP | |
| 20.05.2010 | VoiceMail System - language packs | Firmware | 2.11 MB | ZIP | |
| 20.07.2010 | OLI-2-3-7 - ethernet-modul-firmware | Firmware | 11.04 MB | ZIP | |
| 22.03.2010 | OLI-2-3-6 - ethernet-modul-firmware | Firmware | 10.94 MB | ZIP | |
| 22.03.2010 | FW 4.06rev25-DE - the latest release of firmware version 4.06 (Deutch) | Firmware | 106.10 kB | ZIP | |
| 22.03.2010 | FW 4.06rev25-EN - the latest release of firmware version 4.06 (English) | Firmware | 105.97 kB | ZIP | |
| 22.03.2010 | FW 4.07rev9-DE - the latest release of firmware version 4.07 (Deutch) | Firmware | 108.18 kB | ZIP | |
| 22.03.2010 | FW 4.07rev9-EN - the latest release of firmware version 4.07 (English) | Firmware | 108.05 kB | ZIP | |
| 28.02.2011 | 2N® IVR Editor manual 1.0.2 | Manual | 1.60 MB | ||
| 02.02.2011 | 2N® Omega Lite PBX Assistant - manual ver. 1.2 | Manual | 1.43 MB | ||
| 01.02.2011 | 2N® Omega series - Configuration Tool manual ver. 1.10 | Manual | 1.23 MB | ||
| 23.09.2010 | 2N® Omega series - Configuration Tool manual ver. 1.9 | Manual | 1.61 MB | ||
| 19.05.2010 | 2N® Omega series - VoIP manual ver. 1.4 | Manual | 3.89 MB | ||
| 19.05.2010 | 2N® Omega Lite - Installation Manual ver 1.9 | Manual | 3.31 MB | ||
| 19.05.2010 | 2N® Omega Lite - Configuration Tool manual ver.1.8 | Manual | 1.57 MB | ||
| 10.05.2010 | 2N® Omega Lite - Configuration Tool manual | Manual | 1.57 MB | ||
| 22.03.2010 | 2N® Omega Lite - Basic Services | Manual | 1.38 MB | ||
| 22.03.2010 | 2N® Omega Lite - Installation Manual | Manual | 1.37 MB | ||
| 22.03.2010 | 2N® Omega Lite - Operator Services | Manual | 1020.76 kB | ||
| 22.03.2010 | 2N® Omega Lite Panel - manual | Manual | 338.65 kB | ||
| 22.03.2010 | 2N® Omega Lite PBX Assistant - manual | Manual | 1.49 MB | ||
| 22.03.2010 | 2N® Omega Lite - Quick Guide | Manual | 32.36 kB | ||
| 22.03.2010 | 2N® StarPoint 500 - manual | Manual | 818.10 kB | ||
| 22.03.2010 | 2N® Omega Series - Voicemail | Manual | 807.04 kB | ||
| 22.03.2010 | 2N® Omega Series - VoIP manual | Manual | 2.53 MB |
2N® Omega Lite UMTS
| Date | Name | Category | Size | Type | Download |
|---|---|---|---|---|---|
| 22.03.2010 | 2N® Omega Series - Product leaflet | Leaflet | 1.95 MB | ||
| 22.03.2010 | 2N® Omega 48 - Case Study | Leaflet | 2.37 MB | ||
| 22.03.2010 | 2N® Omega series - UMTS leaflet | Leaflet | 623.50 kB | ||
| 22.03.2010 | 2N® Omega series - overview leaflet | Leaflet | 1.18 MB | ||
| 22.03.2010 | 2N® Omega Lite - Declaration of Conformity | Certificate | 81.99 kB | ||
| 01.02.2011 | PBX Assistant 1.05K | Software | 10.39 MB | ZIP | |
| 01.02.2011 | CT 4.10E | Software | 6.18 MB | ZIP | |
| 27.01.2011 | 2N® IVR Editor v.1.0 | Software | 3.60 MB | ZIP | |
| 30.05.2010 | CT 4.08D | Software | 5.49 MB | ZIP | |
| 10.05.2010 | CT 4.07H | Software | 5.44 MB | ZIP | |
| 10.05.2010 | CT 4.06V | Software | 5.35 MB | ZIP | |
| 14.04.2010 | CT 4.05Y - Configuration Tool | Software | 4.82 MB | ZIP | |
| 22.03.2010 | Ethernet modul USB driver | Software | 1.01 kB | ZIP | |
| 22.03.2010 | Monitoring software for the PBX operator (firmware version 4.07) | Software | 1013.06 kB | ZIP | |
| 22.03.2010 | Monitoring software for the PBX operator (firmware version 4.06) | Software | 1013.03 kB | ZIP | |
| 22.03.2010 | 2N® Omega Lite PBX Assistant 1.02H | Software | 7.01 MB | ZIP | |
| 22.03.2010 | TSP driver 1.8 | Software | 3.63 MB | ZIP | |
| 01.02.2011 | FW 4.10rev6-EN | Firmware | 114.24 kB | ZIP | |
| 01.02.2011 | FW 4.10rev6-DE | Firmware | 114.40 kB | ZIP | |
| 30.05.2010 | FW 4.08rev7-DE | Firmware | 110.83 kB | ZIP | |
| 31.05.2010 | FW 4.08rev7-EN | Firmware | 110.68 kB | ZIP | |
| 20.05.2010 | VoiceMail System - language packs | Firmware | 2.11 MB | ZIP | |
| 20.07.2010 | OLI-2-3-7 - ethernet-modul-firmware | Firmware | 11.04 MB | ZIP | |
| 22.03.2010 | OLI-2-3-6 - ethernet-modul-firmware | Firmware | 10.94 MB | ZIP | |
| 22.03.2010 | FW 4.06rev25-DE - the latest release of firmware version 4.06 (Deutch) | Firmware | 106.10 kB | ZIP | |
| 22.03.2010 | FW 4.06rev25-EN - the latest release of firmware version 4.06 (English) | Firmware | 105.97 kB | ZIP | |
| 22.03.2010 | FW 4.07rev9-DE - the latest release of firmware version 4.07 (Deutch) | Firmware | 108.18 kB | ZIP | |
| 22.03.2010 | FW 4.07rev9-EN - the latest release of firmware version 4.07 (English) | Firmware | 108.05 kB | ZIP | |
| 01.02.2011 | 2N® Omega series - Configuration Tool manual ver. 1.10 | Manual | 1.23 MB | ||
| 01.12.2010 | 2N® IVR Editor manual EN 1.0 | Manual | 1.44 MB | ||
| 19.05.2010 | 2N® Omega series - VoIP manual ver. 1.4 | Manual | 3.89 MB | ||
| 19.05.2010 | 2N® Omega Lite - Installation Manual ver 1.9 | Manual | 3.31 MB | ||
| 19.05.2010 | 2N® Omega Lite - Configuration Tool manual ver.1.8 | Manual | 1.57 MB | ||
| 22.03.2010 | 2N® Omega Lite - Basic Services | Manual | 1.38 MB | ||
| 22.03.2010 | 2N® Omega Lite - Operator Services | Manual | 1020.76 kB | ||
| 22.03.2010 | 2N® Omega Lite Panel - manual | Manual | 338.65 kB | ||
| 22.03.2010 | 2N® Omega Lite PBX Assistant - manual | Manual | 1.49 MB | ||
| 22.03.2010 | 2N® Omega Lite - Quick Guide | Manual | 32.36 kB | ||
| 22.03.2010 | 2N® StarPoint 500 - manual | Manual | 818.10 kB | ||
| 22.03.2010 | 2N® Omega Series - Voicemail | Manual | 807.04 kB |
2N® SIM Star Server
| Date | Name | Category | Size | Type | Download |
|---|---|---|---|---|---|
| 02.03.2013 | SIM bank 2N® SIM Star - Product leaflet (EN) | Leaflet | 1.38 MB | ||
| 02.03.2013 | SIM managment 2N® SIM Star - User guide (EN) | Manual | 1.67 MB |
2N® SingleTalk
| Date | Name | Category | Size | Type | Download |
|---|---|---|---|---|---|
| 28.01.2013 | Lift intercom 2N® SingleTalk - Leaflet (EN) | Leaflet | 622.16 kB | ||
| 28.01.2013 | Lift solution 2N® SingleTalk - Description (EN) | Leaflet | 69.28 kB | ||
| 28.01.2013 | Certificate for 2N® SingleTalk - TUV certificate (EN) | Certificate | 211.15 kB | ||
| 22.01.2013 | Lift emergency phone 2N® SingleTalk - Manual (EN), version 6.2 | Manual | 2.28 MB |
2N® SIP Speaker
| Date | Name | Category | Size | Type | Download |
|---|---|---|---|---|---|
| 13.05.2013 | Audio distribution system 2N® SIP Speaker - Product leaflet (EN) | Leaflet | 1.33 MB | ||
| 23.01.2013 | IP paging system 2N® SIP Speaker - Presentation (EN) | Presentation | 1.03 MB | PPTX | |
| 23.01.2013 | Audio distribution system 2N® SIP Speaker - Firmware v1.15.4 | Firmware | 3.83 MB | BIN | |
| 24.01.2013 | Public IP paging system 2N® SIP Speaker - User manual version 1.15 (EN) | Manual | 2.51 MB |
2N® SmartCOM
| Date | Name | Category | Size | Type | Download |
|---|---|---|---|---|---|
| 21.02.2013 | 2N M2M Solutions - leaflet (EN) | Leaflet | 1.88 MB | ||
| 28.01.2013 | M2M Solution 2N® SmartCom - Product Leaflet (EN) | Leaflet | 1.31 MB | ||
| 28.01.2013 | M2M Solution 2N® SmartCom - Product presentation (EN) | Presentation | 915.96 kB | ||
| 28.01.2013 | M2M Solution 2N® SmartCom - Terminal configuration program 1.0.2.3 | Software | 636.43 kB | ZIP | |
| 28.01.2013 | M2M Solution 2N® SmartCom server software platform 1.6.0 | Software | 1.73 MB | EXE | |
| 28.01.2013 | M2M Solution 2N® SmartCom Control panel 1.6.0 - Server remote control tool | Software | 2.42 MB | MSI | |
| 28.01.2013 | M2M Solution 2N® SmartCom - Firmware version 1.6.0 | Firmware | 102.95 kB | BIN | |
| 28.01.2013 | M2M Solution 2N® SmartCom - User Manual 1.7.1 (EN) | Manual | 3.14 MB | ||
| 28.01.2013 | M2M Solution 2N® SmartCom - Quick guide | Manual | 153.55 kB |
2N® SmartCOM Pro
2N® SmartGate
| Date | Name | Category | Size | Type | Download |
|---|---|---|---|---|---|
| 28.01.2013 | Analogue GSM gateway 2N® EasyGate, 2N® SmartGate - Product leaflet (EN) | Leaflet | 330.92 kB | ||
| 28.01.2013 | Certificate for 2N® SmartGate - Declaration of Conformity (EN) | Certificate | 95.18 kB | ||
| 02.04.2013 | PCManagerUNI208 X_6_6 - Universal programming tool | Software | 1.01 MB | ZIP | |
| 02.04.2013 | GSM Gateway 2N® EasyGate GSM/UMTS modem driver v1.7 | Software | 256 B | ZIP | |
| 23.01.2013 | Analogue GSM gateway 2N® SmartGate - Quick Start (EN) | Manual | 1.18 MB | ||
| 23.01.2013 | Fixed line replacement with 2N® SmartGate - Manual (EN) | Manual | 2.18 MB | ||
| 28.01.2013 | How to set up Baby Call in 2N® SmartGate (EN) | How to | 169.07 kB |
2N® SmartGate UMTS
| Date | Name | Category | Size | Type | Download |
|---|---|---|---|---|---|
| 28.01.2013 | Fixed line replacement with 2N® SmartGate UMTS - Leaflet (EN) | Leaflet | 1.63 MB | ||
| 28.01.2013 | Certificate for 2N® SmartGate UMTS - EC Declaration of Conformity (EN) | Certificate | 95.53 kB | ||
| 02.04.2013 | PCManagerUNI208 X_6_6 - Universal programming tool | Software | 1.01 MB | ZIP | |
| 21.01.2013 | Driver for USB (FTDI) | Software | 1.65 MB | EXE | |
| 23.01.2013 | Analogue UMTS gateway 2N® SmartGate UMTS - Quick Start (EN) | Manual | 832.63 kB | ||
| 23.01.2013 | Analogue UMTS gateway 2N® SmartGate UMTS - Manual (EN) | Manual | 1.74 MB |
2N® SpeedRoute
| Date | Name | Category | Size | Type | Download |
|---|---|---|---|---|---|
| 22.02.2013 | LTE wireless router 2N® SpeedRoute - Product Leaflet (EN) | Leaflet | 2.98 MB | ||
| 15.03.2013 | 4G Router 2N® SpeedRoute 501820 Firmware 3.0.5 | Firmware | 12.46 MB | FW | |
| 10.04.2013 | 4G Router 2N® SpeedRoute 501830 Firmware 3.0.5 | Firmware | 12.46 MB | FW | |
| 10.04.2013 | 4G Router 2N® SpeedRoute 501800 & 501810 Firmware 3.0.5 | Firmware | 11.84 MB | FW | |
| 15.03.2013 | 4G wireless router 2N® SpeedRoute - User manual version 1.01 (EN) | Manual | 2.86 MB |
2N® StarGate
| Date | Name | Category | Size | Type | Download |
|---|---|---|---|---|---|
| 15.03.2013 | VOIP/PRI gateway 2N® StarGate - Leaflet (EN) | Leaflet | 7.05 MB | ||
| 01.03.2013 | VOIP/PRI/GSM/UMTS gateway 2N® StarGate - Product presentation (EN) | Presentation | 244.12 kB | ||
| 01.03.2013 | VOIP/PRI/GSM/UMTS gateway 2N® StarGate - Product presentation (EN) | Presentation | 1.18 MB | PPT | |
| 15.03.2013 | Cost Savings with VOIP/PRI gateway 2N® StarGate - Case study (EN) | Presentation | 199.68 kB | ||
| 15.03.2013 | Cost Savings with VOIP/PRI gateway 2N® StarGate - Case study (EN) | Presentation | 876.00 kB | PPT | |
| 01.03.2013 | PRI backup solution with 2N® StarGate - Case study (EN) | Presentation | 202.47 kB | ||
| 01.03.2013 | PRI backup solution with 2N® StarGate - Case study (EN) | Presentation | 831.00 kB | PPT | |
| 15.03.2013 | Digital & VoIP gateway 2N® StarGate - Configuration tool 2.16.16 (EN) | Software | 823.61 kB | ZIP | |
| 15.03.2013 | Digital & VoIP gateway 2N® StarGate - Configuration tool 2.0i (EN) | Software | 1.41 MB | ZIP | |
| 01.03.2013 | VOIP/PRI/GSM/UMTS gateways 2N® StarGate & BlueTower - Firmware 2.30.13 (EN) | Firmware | 254.88 kB | ZIP | |
| 01.03.2013 | VOIP/PRI/GSM/UMTS gateways 2N® StarGate & BlueTower - Firmware 2.20.51 (EN) | Firmware | 237.92 kB | ZIP | |
| 01.03.2013 | VOIP/PRI/GSM/UMTS gateways 2N® StarGate & BlueTower - Firmware 2.17.12 (EN) | Firmware | 186.08 kB | ZIP | |
| 15.03.2013 | Digital & VoIP gateway 2N® StarGate - Manual (EN) | Manual | 5.22 MB | ||
| 15.03.2013 | GSM/VOIP gateways 2N® StarGate & BlueTower - Interconnection guide with Siemens HiPath (EN) | How to | 325.88 kB | ||
| 15.03.2013 | GSM/VOIP gateways 2N® StarGate & BlueTower - Interconnection guide with Alcatel OXO (EN) | How to | 405.57 kB |
2N® StarGate VoIP
| Date | Name | Category | Size | Type | Download |
|---|---|---|---|---|---|
| 15.03.2013 | VOIP/PRI gateway 2N® StarGate - Leaflet (EN) | Leaflet | 7.05 MB | ||
| 01.03.2013 | VOIP/PRI/GSM/UMTS gateway 2N® StarGate - Product presentation (EN) | Presentation | 244.12 kB | ||
| 01.03.2013 | VOIP/PRI/GSM/UMTS gateway 2N® StarGate - Product presentation (EN) | Presentation | 1.18 MB | PPT | |
| 15.03.2013 | Cost Savings with VOIP/PRI gateway 2N® StarGate - Case study (EN) | Presentation | 199.68 kB | ||
| 15.03.2013 | Cost Savings with VOIP/PRI gateway 2N® StarGate - Case study (EN) | Presentation | 876.00 kB | PPT | |
| 01.03.2013 | PRI backup solution with 2N® StarGate - Case study (EN) | Presentation | 202.47 kB | ||
| 01.03.2013 | PRI backup solution with 2N® StarGate - Case study (EN) | Presentation | 831.00 kB | PPT | |
| 01.03.2013 | VOIP/PRI/GSM/UMTS gateways 2N® StarGate & BlueTower - Firmware 2.30.13 (EN) | Firmware | 254.88 kB | ZIP | |
| 15.03.2013 | Digital & VoIP gateway 2N® StarGate - Manual (EN) | Manual | 5.22 MB | ||
| 15.03.2013 | GSM/VOIP gateways 2N® StarGate & BlueTower - Interconnection guide with Alcatel OXO (EN) | How to | 405.57 kB |
2N® VoiceBlue Enterprise
| Date | Name | Category | Size | Type | Download |
|---|---|---|---|---|---|
| 22.03.2010 | 2N® VoiceBlue Enterprise - Declaration of Conformity | Certificate | 82.66 kB | ||
| 22.03.2010 | 2N® VoiceBlue Enterprise USB driver | Software | 973 B | ZIP | |
| 01.02.2012 | VBE-2-3-18 OLD HW | Firmware | 9.09 MB | ||
| 01.02.2012 | VBE-2-3-18 NEW HW | Firmware | 10.86 MB | ||
| 10.10.2011 | VBE-2-3-16 OLD HW | Firmware | 9.10 MB | ZIP | |
| 09.10.2011 | VBE-2-3-16 NEW HW | Firmware | 10.86 MB | ZIP | |
| 11.03.2011 | VBE-2-3-13 OLD HW | Firmware | 9.09 MB | ZIP | |
| 11.03.2011 | VBE-2-3-13 NEW HW | Firmware | 10.86 MB | ZIP | |
| 16.11.2010 | VBE-2-3-11 OLD HW | Firmware | 9.04 MB | ZIP | |
| 16.11.2010 | VBE-2-3-11 NEW HW | Firmware | 10.85 MB | ZIP | |
| 16.05.2010 | VBE-2-3-7 OLD HW | Firmware | 9.00 MB | ZIP | |
| 16.05.2010 | VB3-2-3-7 NEW HW | Firmware | 10.79 MB | ZIP | |
| 22.03.2010 | VB3-2-2-10 NEW HW | Firmware | 12.70 MB | ZIP | |
| 22.03.2010 | VBE-2-2-10 OLD HW | Firmware | 10.58 MB | ZIP | |
| 09.10.2011 | 2N® OfficeRoute - User manual 1.8.2 | Manual | 4.19 MB |
2N® VoiceBlue Lite
| Date | Name | Category | Size | Type | Download |
|---|---|---|---|---|---|
| 27.01.2011 | 2N® VoiceBlue Lite - product leaflet | Leaflet | 529.73 kB | ||
| 27.01.2011 | 2N® VoiceBlue Lite - product presentation | Presentation | 158.02 kB | ||
| 27.01.2011 | 2N® VoiceBlue Lite - product presentation | Presentation | 949.00 kB | PPT | |
| 27.01.2011 | 2N® VoiceBlue Lite - Case Study - Cost Savings | Presentation | 194.96 kB | ||
| 27.01.2011 | 2N® VoiceBlue Lite - Case Study - Cost Savings | Presentation | 943.00 kB | PPT | |
| 27.01.2011 | 2N® VoiceBlue Lite - Case Study - Mobility Extension | Presentation | 188.17 kB | ||
| 27.01.2011 | 2N® VoiceBlue Lite - Case Study - Mobility Extension | Presentation | 886.00 kB | PPT | |
| 27.01.2011 | 2N® VoiceBlue Lite - declaration of conformity | Certificate | 81.56 kB | ||
| 19.05.2011 | 2N® VoiceBlue Lite - Configuration tool 2.0x | Software | 1.36 MB | ZIP | |
| 13.11.2012 | 2N® VoiceBlue Lite - Firmware 02.08.02 | Firmware | 413.39 kB | ZIP | |
| 27.01.2011 | 2N® VoiceBlue Lite - Manual | Manual | 4.52 MB | ||
| 27.01.2011 | How to install 2N® VoiceBlue Lite | How to | 1.05 MB | ||
| 27.01.2011 | How to connect 2N® VoiceBlue Lite to Siemens HiPath | How to | 1.66 MB | ||
| 27.01.2011 | How to connect 2N® VoiceBlue Lite to Alcatel OXO | How to | 1.32 MB | ||
| 26.04.2011 | 2N® VoiceBlue Lite - Supported IP PBXs | Other | 480.24 kB |
2N® VoiceBlue MAX
| Date | Name | Category | Size | Type | Download |
|---|---|---|---|---|---|
| 03.05.2013 | VOIP gateway 2N® VoiceBlue MAX - Product leaflet (EN) | Leaflet | 1.86 MB | ||
| 03.05.2013 | VOIP/GSM/UMTS gateway 2N® VoiceBlue MAX - IP Scanner (EN) | Software | 41.40 kB | ZIP | |
| 03.05.2013 | GSM/UMTS gateway 2N® VoiceBlue MAX - Firmware 1.12.0 (EN) | Firmware | 2.22 MB | ZIP | |
| 30.04.2013 | VOIP gateway 2N® VoiceBlue MAX - User Manual (EN) | Manual | 3.70 MB |
2N® VoiceBlue Next
Mobility Extension
| Date | Name | Category | Size | Type | Download |
|---|---|---|---|---|---|
| 16.07.2010 | Mobility Extension Application Symbian | Software | 92.30 kB | SIS | |
| 12.07.2010 | Manual fo Mobility Extension Application | Manual | 242.92 kB |
SMS Server
| Date | Name | Category | Size | Type | Download |
|---|---|---|---|---|---|
| 18.02.2011 | SMS Client 1.3.23 | Software | 1.34 MB | ZIP | |
| 18.02.2011 | SMS Server 1.4.17 | Software | 4.95 MB | ZIP | |
| 16.05.2010 | SMS Client 1.3.21 | Software | 1.34 MB | ZIP | |
| 16.05.2010 | SMS Server 1.4.15 | Software | 4.95 MB | ZIP | |
| 22.03.2010 | SMS Client 1.3.19 | Software | 1.33 MB | ZIP | |
| 22.03.2010 | SMS Server 1.4.10 | Software | 4.94 MB | ZIP | |
| 22.03.2010 | 2N® SMS Server manual-EN | Software | 304.85 kB |
XAPI Server
| Date | Name | Category | Size | Type | Download |
|---|---|---|---|---|---|
| 08.03.2010 | 2N® XAPI Server - tutorial | Presentation | 2.63 MB | ZIP | |
| 27.09.2011 | XAPI Server 1.20H | Software | 5.00 MB | ZIP | |
| 18.02.2011 | XAPI Server 1.20E | Software | 4.93 MB | ZIP | |
| 24.09.2010 | XAPI Server 1.20A | Software | 4.93 MB | ZIP | |
| 22.07.2010 | XAPI Server 1.17R | Software | 4.89 MB | ZIP | |
| 03.06.2010 | XAPI Server 1.19D | Software | 4.92 MB | ZIP | |
| 22.03.2010 | XAPI Server 1.18I | Software | 4.92 MB | ZIP | |
| 22.03.2010 | XAPI Server console 1.04 | Software | 847.95 kB | ZIP |
Other
| Date | Name | Size | Type | Download |
|---|---|---|---|---|
| 23.01.2013 | DDI solution for mobile networks with 2N® NetStar platform - leaftlet (EN) | 1.36 MB | ||
| 24.02.2012 | M2M | 3.30 MB | ZIP | |
| 23.02.2012 | MSC Booster | 2.10 MB | ZIP | |
| 23.02.2012 | LTE Back-up Solution | 632.51 kB | ZIP | |
| 23.02.2012 | Centrex IP Door Access | 2.62 MB | ZIP | |
| 23.02.2012 | Centrex IP Audio | 1.15 MB | ZIP | |
| 08.03.2010 | 2N® XAPI Server - tutorial | 2.63 MB | ZIP | |
| 08.03.2010 | 2N® VoiceBlue Lite - tutorial | 9.70 MB | ZIP | |
| 02.03.2013 | SIM management 2N® SIM Star - Tutorial (EN) | 21.97 MB | ZIP | |
| 08.03.2010 | 2N® Omega Series - tutorial | 22.87 MB | ZIP | |
| 08.03.2010 | 2N® Omega Lite - tutorial | 16.07 MB | ZIP | |
| 18.01.2013 | PBX training 2N® NetStar - tutorial presentation (EN) | 20.67 MB | ZIP | |
| 08.03.2010 | 2N® Helios IP - tutorial | 60.52 MB | ZIP | |
| 10.05.2012 | Certificate confirming compatibility of 2N IP door intercoms with Alcatel PBXs | 244.92 kB | ||
| 18.11.2011 | Avaya Compliance Certificate - 2N Helios IP Vario door intercom | 68.84 kB | ||
| 15.03.2013 | 3G router 2N® EasyRoute - FCC Certificate (EN) | 220.81 kB | ||
| 01.03.2013 | VOIP/GSM/UMTS gateway 2N® VoiceBlue Next - Cisco Compatibility Certificate (EN) | 32.56 kB | ||
| 18.06.2010 | 2N Helios IP - Cisco Compatibility Certificate | 98.23 kB | ||
| 18.06.2010 | 2N Helios IP - Cisco Compatibility Certificate | 98.23 kB | ||
| 10.01.2013 | Omega VOIP module | 9.15 MB | ||
| 26.08.2010 | 2N® Helios IP Firmware version 1.9.1 | 3.72 MB | BIN | |
| 18.01.2013 | PBX 2N® NetStar - Configuration Manual (EN) | 1.28 MB | ||
| 08.03.2010 | 2N® Omega Series - Operator Services | 1020.76 kB | ||
| 08.03.2010 | 2N® Omega Series - Instalation Manual | 1.14 MB | ||
| 08.03.2010 | 2N® Omega Series - Basic Services | 1.38 MB | ||
| 08.03.2010 | 2N® SmartGate - User Manual | 1.91 MB | ||
| 08.03.2010 | 2N® EasyGate - User Manual | 1.89 MB | ||
| 08.03.2010 | 2N® VoiceBlue Enterprise - User Manual | 886.01 kB | ||
| 08.03.2010 | 2N® VoiceBlue - User Manual | 4.52 MB | ||
| 08.03.2010 | 2N® OfficeRoute - User Manual | 660.84 kB | ||
| 08.03.2010 | 2N PRI Gateways - User Manual | 3.64 MB | ||
| 02.05.2011 | 2N OpenStage model comparison | 592.54 kB | ||
| 04.03.2013 | 2N Summary E-Newsletter February 2013 | 257.45 kB | ||
| 14.02.2013 | 2N Summary E-Newsletter January 2013 | 285.93 kB | ||
| 11.01.2013 | Special E-Newsletter - IP Intercom Christmas Offer - Extended - December 2012 | 311.39 kB | ||
| 11.01.2013 | Special E-Newsletter - IP Intercom Christmas Offer - November 2012 | 309.77 kB | ||
| 11.01.2013 | 2N Summary E-Newsletter December 2012 | 300.15 kB | ||
| 06.12.2012 | 2N M2M E-Newsletter December 2012 | 234.53 kB | ||
| 06.12.2012 | 2N Summary E-Newsletter November 2012 | 230.48 kB | ||
| 02.11.2012 | 2N Summary E-Newsletter October 2012 | 259.86 kB | ||
| 04.10.2012 | Technical Support Ticketing System September 2012 | 180.02 kB | ||
| 04.10.2012 | 2N Summary E-Newsletter September 2012 | 235.74 kB | ||
| 04.10.2012 | 2N Summary E-Newsletter August 2012 | 230.39 kB | ||
| 27.07.2012 | 2N Summary E-Newsletter July 2012 | 224.79 kB | ||
| 13.07.2012 | 2N M2M E-Newsletter June 2012 | 245.38 kB | ||
| 03.07.2012 | 2N Summary E-Newsletter June 2012 | 216.80 kB | ||
| 22.06.2012 | 2N IP Intercoms Microsite Contest E-Newsletter | 183.72 kB | ||
| 08.06.2012 | 2N IP Intercoms Microsite E-Newsletter | 224.95 kB | ||
| 08.06.2012 | 2N Summary E-Newsletter May 2012 | 183.38 kB | ||
| 08.06.2012 | 2N Summary E-Newsletter April 2012 | 191.59 kB | ||
| 23.04.2012 | 2N SIP Speaker E-Newsletter | 208.37 kB | ||
| 23.04.2012 | 2N Summary E-Newsletter March 2012 | 220.44 kB | ||
| 23.04.2012 | 2N Summary E-Newsletter February 2012 | 197.62 kB | ||
| 27.01.2012 | 2N Summary E-Newsletter January 2012 | 223.97 kB | ||
| 19.12.2011 | 2N Summary E-Newsletter December 2011 | 198.09 kB | ||
| 09.12.2011 | 2N Summary E-Newsletter November 2011 | 212.15 kB | ||
| 09.12.2011 | 2N Summary E-Newsletter October 2011 | 210.38 kB | ||
| 07.10.2011 | 2N Summary E-Newsletter September 2011 | 222.17 kB | ||
| 12.09.2011 | 2N Summary E-Newsletter August 2011 | 233.59 kB | ||
| 05.08.2011 | 2N NetSpeaker E-Newsletter June 2011 | 147.50 kB | ||
| 05.08.2011 | 2N Summary E-Newsletter June 2011 | 217.21 kB | ||
| 05.08.2011 | 2N Summary E-Newsletter May 2011 | 234.71 kB | ||
| 05.08.2011 | 2N Summary E-Newsletter April 2011 | 207.62 kB | ||
| 29.07.2011 | 2N Summary E-Newsletter July 2011 | 214.01 kB | ||
| 22.02.2011 | 2N Lift E-newsletter February 2011 | 226.72 kB | ||
| 11.11.2011 | 2N Door Intercoms E-Newsletter February 2011 | 245.98 kB | ||
| 08.02.2011 | 2N Summary E-Newsletter January 2011 | 245.74 kB | ||
| 08.02.2011 | 2N Gateways E-Newsletter January 2011 | 331.28 kB | ||
| 11.11.2011 | 2N Door Intercoms E-Newsletter December 2010 | 211.44 kB | ||
| 14.01.2011 | 2N Lift E-Newsletter January 2011 | 281.71 kB | ||
| 08.12.2010 | 2N E-Newsletter November 2010 Public | 186.01 kB | ||
| 08.12.2010 | 2N E-Newsletter November 2010 | 197.13 kB | ||
| 24.11.2010 | Social Networks Campaign | 205.33 kB | ||
| 01.11.2010 | 2N E-newsletter October 2010 | 349.66 kB | ||
| 01.11.2010 | 2N E-newsletter October 2010 | 349.66 kB | ||
| 05.10.2010 | 2N E-newsletter September 2010 | 126.04 kB | ||
| 18.08.2010 | 2N E-newsletter August 2010 | 183.51 kB | ||
| 18.08.2010 | 2N E-newsletter August 2010 | 183.51 kB | ||
| 22.06.2010 | 2N E-newsletter June 2010 - 2N Helios & 2N Helios IP | 151.08 kB | ||
| 19.05.2010 | 2N E-newsletter May 2010 | 68.57 kB | ||
| 18.02.2010 | 2N E-newsletter CeBIT 2010 | 113.92 kB | ||
| 19.01.2010 | 2N E-newsletter MWC in Barcelona 2010 | 112.13 kB | ||
| 23.12.2009 | 2N E-newsletter December 2009 | 68.47 kB | ||
| 15.12.2009 | 2N E-newsletter December 2009 - Helios IP | 40.33 kB | ||
| 27.11.2009 | 2N E-newsletter November 2009 | 60.67 kB | ||
| 24.11.2009 | 2N E-newsletter November 2009 - Helios IP | 44.87 kB | ||
| 13.11.2009 | 2N E-newsletter November 2009 - Wi-Fi Hot Spot | 45.43 kB | ||
| 30.10.2009 | 2N E-newsletter October 2009 | 71.82 kB | ||
| 10.09.2009 | 2N E-newsletter September 2009 | 182.01 kB | ||
| 10.08.2009 | 2N E-newsletter August 2009 | 204.24 kB | ||
| 07.07.2009 | 2N E-newsletter July 2009 | 198.36 kB | ||
| 27.05.2009 | 2N E-newsletter May 2/2 2009 | 200.55 kB | ||
| 13.05.2009 | 2N E-newsletter May 1/2 2009 | 368.91 kB | ||
| 13.03.2009 | 2N E-newsletter March 2009 | 137.93 kB | ||
| 19.02.2009 | 2N E-newsletter February 2009 | 60.90 kB | ||
| 21.01.2009 | 2N E-newsletter January 2009 | 64.20 kB | ||
| 26.04.2013 | 2N Company Wallpaper | 10.86 MB | ZIP | |
| 19.02.2013 | Mobile World Congress Barcelona 2013 - Invitation | 767.95 kB | ||
| 29.04.2013 | 2N TELEKOMUNIKACE - Corporate presentation (EN) | 921.15 kB | ||
| 26.03.2013 | Extended warranties for 2N products | 1.75 MB | ||
| 31.05.2012 | Complaint and Service Rules | 84.14 kB | ||
| 03.12.2012 | Repair List | 270.87 kB | ||
| 07.12.2011 | Warranty Certificate | 25.66 kB | ||
| 10.06.2011 | The 2N Code | 76.05 kB | ||
| 03.05.2011 | 2N OpenStage technical parameters comparison | 270.63 kB | ||
| 12.10.2010 | Lift Milano 2010 - Floor plan | 444.09 kB | ||
| 29.09.2010 | Adobe Connect Pro Tutorial | 4.66 MB | WMV | |
| 29.04.2013 | 2N Screensaver | 903.25 kB | ZIP | |
| 29.04.2013 | 2N Screensaver | 903.25 kB | ZIP | |
| 13.04.2010 | Marketing support package - exhibition | 21.26 kB | ||
| 13.04.2010 | Marketing support package | 21.88 kB |
Configuration tool for 2N® BRI Lite and 2N® BRI Enterprise models with USB port.
Ethernet software for 2N® BRI Enterprise model with Ethernet and USB ports.
USB drivers for 2N® BRI Lite and 2N® BRI Enterprise modeles with USB port.
Firmware for 2N® BRI Lite and 2N® BRI Enterprise models with Ethernet port and no USB port.
Firmware for 2N® BRI Lite and 2N® BRI Enterprise models with USB port.
Latest firmware 2.04.xx line: 2.04.21
Latest firmware 2.05.xx line: 2.05.22
Latest firmware 2.04.xx line: 2.04.21
Latest firmware 2.05.xx line: 2.05.22
New Features
1. SNMP protocol support
2. Log files saved in Flash memeory - accessible after restart.
3. Username a Password in menu WAN PPPoE length 63 chracters
Fixed Bugs:
1. All characters in the APN name permited (problem with ',')
2. Vendor OID corrected to 6530 (there was incorrect 6535)
3. Switching to backup route after FUP setting fixed
1. SNMP protocol support
2. Log files saved in Flash memeory - accessible after restart.
3. Username a Password in menu WAN PPPoE length 63 chracters
Fixed Bugs:
1. All characters in the APN name permited (problem with ',')
2. Vendor OID corrected to 6530 (there was incorrect 6535)
3. Switching to backup route after FUP setting fixed
New Features
1. SNMP protocol support
2. Log files saved in Flash memeory - accessible after restart.
3. Username a Password in menu WAN PPPoE length 63 chracters
Fixed Bugs:
1. All characters in the APN name permited (problem with ',')
2. Vendor OID corrected to 6530 (there was incorrect 6535)
3. Switching to backup route after FUP setting fixed
1. SNMP protocol support
2. Log files saved in Flash memeory - accessible after restart.
3. Username a Password in menu WAN PPPoE length 63 chracters
Fixed Bugs:
1. All characters in the APN name permited (problem with ',')
2. Vendor OID corrected to 6530 (there was incorrect 6535)
3. Switching to backup route after FUP setting fixed
New Features
1. SNMP protocol support
2. Log files saved in Flash memeory - accessible after restart.
3. Username a Password in menu WAN PPPoE length 63 chracters
Fixed Bugs:
1. All characters in the APN name permited (problem with ',')
2. Vendor OID corrected to 6530 (there was incorrect 6535)
3. Switching to backup route after FUP setting fixed
1. SNMP protocol support
2. Log files saved in Flash memeory - accessible after restart.
3. Username a Password in menu WAN PPPoE length 63 chracters
Fixed Bugs:
1. All characters in the APN name permited (problem with ',')
2. Vendor OID corrected to 6530 (there was incorrect 6535)
3. Switching to backup route after FUP setting fixed
New Features
1. SNMP protocol support
2. Log files saved in Flash memeory - accessible after restart.
3. Username a Password in menu WAN PPPoE length 63 chracters
Fixed Bugs:
1. All characters in the APN name permited (problem with ',')
2. Vendor OID corrected to 6530 (there was incorrect 6535)
3. Switching to backup route after FUP setting fixed
1. SNMP protocol support
2. Log files saved in Flash memeory - accessible after restart.
3. Username a Password in menu WAN PPPoE length 63 chracters
Fixed Bugs:
1. All characters in the APN name permited (problem with ',')
2. Vendor OID corrected to 6530 (there was incorrect 6535)
3. Switching to backup route after FUP setting fixed
Note: when you will run the module fw upgarde you should remove the SIM card from the device (when removing SIM card the device should be switched OFF). Than you can run the upgrade in menu: SETUP/System/Firmware. It will take take appr. 2min (upgrade can end with message Failed). Do the restart of the device and check if the upgrade was successfull, if not run the upgrade process one more time.
Note: when you will run the module fw upgarde you should remove the SIM card from the device (when removing SIM card the device should be switched OFF). Than you can run the upgrade in menu: SETUP/System/Firmware. It will take take appr. 2min (upgrade can end with message Failed). Do the restart of the device and check if the upgrade was successfull, if not run the upgrade process one more time.
- upgrade FW corrections
- increased APN database
- corrections in Czech menu
Features from FW: 1.03.006
- Optimalization of the FW for upload speed
- LCP echo featute (PPP connection parameter)
- ICMP echo: ping feature - Increase APN list
- New feature EasyRoute as a Wi-Fi HotSpot
- Longer time out for remote upgrade - Watchdog on module
- increased APN database
- corrections in Czech menu
Features from FW: 1.03.006
- Optimalization of the FW for upload speed
- LCP echo featute (PPP connection parameter)
- ICMP echo: ping feature - Increase APN list
- New feature EasyRoute as a Wi-Fi HotSpot
- Longer time out for remote upgrade - Watchdog on module
Improvements in compatibility with 2N® Helios IP Mobile.
Minor bugfixes.
Minor bugfixes.
Trial version 30 days
Improvements in compatibility with 2N® Helios IP Mobile.
Minor bugfixes.
Minor bugfixes.
Features
DHCP options 66 support
HTTP/HTTPS automatic updates
DSCP for SIP
Support for PRACK (Provisional Response Acknowledgement)
Improvements
Change of default password enforcement
Password strength evaluation
Ehanced auto update
Several bug fixes
DHCP options 66 support
HTTP/HTTPS automatic updates
DSCP for SIP
Support for PRACK (Provisional Response Acknowledgement)
Improvements
Change of default password enforcement
Password strength evaluation
Ehanced auto update
Several bug fixes
Features
Concurrent calls to multiple numbers - Group call to three numbers at one time
SIP signalization over TCP - Necessary prerequisite to communication with MS Lync
ONVIF support - Helios IP can now be easily integrated into CCTV systems
Automation - Programmable interface for demanding installations
Mobile devices registration using UDP - Enhanced integration with mobile devices
Improvements
TFTP improvements - Better automatic updates, new options for update period and other upgrades
Sending E-mail in case of successfull call - Better usability of the email feature
Show detected hardware - Improvement in web interface
Sending Allow header in SIP messages - SIP improvement
Remove feature Floor&Flat dial from web interface - Unused feature
Avoid interlaving of INVITE and CANCEL messages -SIP improvement
When another quick dial button is pressed, HIP to cancel previous call and initiate a new one. - Better behaviour of the intercom
Cropping picture from camera - Better user experience for video from Helios IP Force
Web interface: four IP addresses of RTSP clients - More security
Time profiles to control RFID card/code access - More security
Deactivation of BUSY tone after call ends - Better user experience, no annoying sounds after call end
Set SIP Display name according HIP model - Better user experience
Sending information about HIP model and Camera availability in response to UDP broadcast - SIP improvement
Provisioning of configuration from NetStar - Integration with 2N NetStar
Concurrent calls to multiple numbers - Group call to three numbers at one time
SIP signalization over TCP - Necessary prerequisite to communication with MS Lync
ONVIF support - Helios IP can now be easily integrated into CCTV systems
Automation - Programmable interface for demanding installations
Mobile devices registration using UDP - Enhanced integration with mobile devices
Improvements
TFTP improvements - Better automatic updates, new options for update period and other upgrades
Sending E-mail in case of successfull call - Better usability of the email feature
Show detected hardware - Improvement in web interface
Sending Allow header in SIP messages - SIP improvement
Remove feature Floor&Flat dial from web interface - Unused feature
Avoid interlaving of INVITE and CANCEL messages -SIP improvement
When another quick dial button is pressed, HIP to cancel previous call and initiate a new one. - Better behaviour of the intercom
Cropping picture from camera - Better user experience for video from Helios IP Force
Web interface: four IP addresses of RTSP clients - More security
Time profiles to control RFID card/code access - More security
Deactivation of BUSY tone after call ends - Better user experience, no annoying sounds after call end
Set SIP Display name according HIP model - Better user experience
Sending information about HIP model and Camera availability in response to UDP broadcast - SIP improvement
Provisioning of configuration from NetStar - Integration with 2N NetStar
Features
PNG picture compression New picture format
HTTPS support Better security of configuration
Multicast send Ability to stream RTP on multicast channel - better integration
MJPEG video codec support New video codec
SMTP over TLS Better integration with public SMTP email servers
Licenses for enhanced packages Support for new licensing policy
Improvement
Add brackets to TO email addresses Better email usability
Switch on infra leds on camera only when camera is used Camera improvement
Lock control by HTTP command ->respons editable Better user value of HTTP command
Time profiles - non stop whole day setting Better time profile usability
Single short beep after card detection Beep when card reader off and wiegand set to output
HIP to accept equally cards from internal and external card reader connected via Wiegand Better compatibility with external RFID card reader
User switch codes for switches 3&4 User codes for 3rd and 4th switch
Downloading xml file from TFTP server Xml configuration file support
PNG picture compression New picture format
HTTPS support Better security of configuration
Multicast send Ability to stream RTP on multicast channel - better integration
MJPEG video codec support New video codec
SMTP over TLS Better integration with public SMTP email servers
Licenses for enhanced packages Support for new licensing policy
Improvement
Add brackets to TO email addresses Better email usability
Switch on infra leds on camera only when camera is used Camera improvement
Lock control by HTTP command ->respons editable Better user value of HTTP command
Time profiles - non stop whole day setting Better time profile usability
Single short beep after card detection Beep when card reader off and wiegand set to output
HIP to accept equally cards from internal and external card reader connected via Wiegand Better compatibility with external RFID card reader
User switch codes for switches 3&4 User codes for 3rd and 4th switch
Downloading xml file from TFTP server Xml configuration file support
Improvements
Better Wiegand interface compatibility, so that the Wiegand now behaves as follows:
Pulse width: 30us to 200us
Pulse distance: 200us to 20ms
Output: push-pull (0-5V)
Input: high impedance without pull-up resistor
Format: 26 bits (even parity bit + 8 bit facility code + 16 bit user ID + odd parity bit)
Minor bugfixes
Better Wiegand interface compatibility, so that the Wiegand now behaves as follows:
Pulse width: 30us to 200us
Pulse distance: 200us to 20ms
Output: push-pull (0-5V)
Input: high impedance without pull-up resistor
Format: 26 bits (even parity bit + 8 bit facility code + 16 bit user ID + odd parity bit)
Minor bugfixes
Improvement
Rename text in card reader input combo - Renaming of too long texts in card reader settings.
Limitation of transmitting bearing frequency on card reader - Better RFID card reader readibility.
Sending video resolution in SDP for H.263 payload type - Better SIP compatibility for Siemens systems.
Add pictogram for Certificates page in web interface - Graphic improvement in web interface.
Call time limit cancel - Option to have no time limit for call.
Shorten dead time between accepting two different cards - At the moment the card reader has an delay after card detection until it can detect another card - this time has been shortened.
Prefix of sequence sent over wiegand interface - Better Wiegand compatibility.
Enable red led activation by both logic levels - More ways to activate red LED diode under card reader antenna cover.
Enable combo box for multicast - Option to enable/disable multicast.
Remove option to disable web server - If a customer disables web server, there are only limited ways how to configure it. It might be confusing and servers no reasonable purpose.
Remove "user active if" feature - Rarely used, therefore removed.
Features
Support for digital input for button on Security Relay -Departure button feature on Security Relay. Good for opening of the door from inside using a button.
EAP-TLS Support 802.1x EAP-TLS support. - Authentication method for network security.
Rename text in card reader input combo - Renaming of too long texts in card reader settings.
Limitation of transmitting bearing frequency on card reader - Better RFID card reader readibility.
Sending video resolution in SDP for H.263 payload type - Better SIP compatibility for Siemens systems.
Add pictogram for Certificates page in web interface - Graphic improvement in web interface.
Call time limit cancel - Option to have no time limit for call.
Shorten dead time between accepting two different cards - At the moment the card reader has an delay after card detection until it can detect another card - this time has been shortened.
Prefix of sequence sent over wiegand interface - Better Wiegand compatibility.
Enable red led activation by both logic levels - More ways to activate red LED diode under card reader antenna cover.
Enable combo box for multicast - Option to enable/disable multicast.
Remove option to disable web server - If a customer disables web server, there are only limited ways how to configure it. It might be confusing and servers no reasonable purpose.
Remove "user active if" feature - Rarely used, therefore removed.
Features
Support for digital input for button on Security Relay -Departure button feature on Security Relay. Good for opening of the door from inside using a button.
EAP-TLS Support 802.1x EAP-TLS support. - Authentication method for network security.
2N Helios IP Force two button version support
Bugfixes
Bugfixes
Features
H.263 support according to RFC-2190 (payload type 34)
Integration of 802.1x/AEP-MD5 supplicant
Improvements
Controlling new relay and active outputs
RTSP for CISCO VSM
H.263 support according to RFC-2190 (payload type 34)
Integration of 802.1x/AEP-MD5 supplicant
Improvements
Controlling new relay and active outputs
RTSP for CISCO VSM
Improvements in compatibility with 2N® Helios IP Mobile.
Minor bugfixes.
Minor bugfixes.
Improvements in compatibility with 2N® Helios IP Mobile.
Minor bugfixes.
Minor bugfixes.
2N® NetSpeaker SW package version 1.3.9 brings these new features and improvements:
- Server optimization: CPU and RAM usage
- TTL adjustable for cross-network multicast: option to setup max. value of TTL
- Displaying 2N NetSpeaker IP address in the Control Panel: menu NetSpeaker Scanner
- High latency and unstable connection improvements
- Better coping with TCP drop outs
- NTP timeout increased
- SDcard induced restart of the device - fixed
- User Interface text corrections
- Server optimization: CPU and RAM usage
- TTL adjustable for cross-network multicast: option to setup max. value of TTL
- Displaying 2N NetSpeaker IP address in the Control Panel: menu NetSpeaker Scanner
- High latency and unstable connection improvements
- Better coping with TCP drop outs
- NTP timeout increased
- SDcard induced restart of the device - fixed
- User Interface text corrections
NetSpeaker SW package version 1.3.6 brings these new features and improvements:
- General RTP sources and destinations (option to receive or send audio from third party devices with RTP support). This feature is under the license (order number: 914202E)
- Pause between messages played from a local microSD card
- Mono streaming support
- improved searching of NsP units in the network
- improvements in Synch. manager
- other small improvements
Applications
- PASSWORD in all applications is in default empty - valid for new installation
- New graphic look: Player application, Console application
- General RTP sources and destinations (option to receive or send audio from third party devices with RTP support). This feature is under the license (order number: 914202E)
- Pause between messages played from a local microSD card
- Mono streaming support
- improved searching of NsP units in the network
- improvements in Synch. manager
- other small improvements
Applications
- PASSWORD in all applications is in default empty - valid for new installation
- New graphic look: Player application, Console application
NetSpeaker SW package version 1.2.5 brings these new features and improvements
Automatic connection of NsP in your network - this automatic configuration is working with NsP which has fw version 1.2.x
Automatic generation of playlists from defined source of music
Improved SIP call quality and latency
Latency reduce to 30ms
Internet radio at scheduler
PLS playlist format support - Internet radio
Support for .wma, .wav, .mp3
Option to activate/deactivate source in the session
Scheduler: tab view - expert menu, option to activate/deactivate session
Function "copy" for Event in scheduler
Audio core - loopback from speakers like a session source
Option to play stuff from SD card, when there is lost of on-line connection
Restart button, SD card format button, synchronized button, test button - NsP flashes and beeps to identify itself
XML API Improvements - playlists, sessions, generated playlists, group of speakers, internet radio, file explorer
Authorization for XML API
HTTP API - Helios Family, Cisco support
Application
INFO panel - help with next steps
HELP in Control panel
New graphic look: session, NetSpeakes & zones, scheduler, Player application, SIP menu
Automatic connection of NsP in your network - this automatic configuration is working with NsP which has fw version 1.2.x
Automatic generation of playlists from defined source of music
Improved SIP call quality and latency
Latency reduce to 30ms
Internet radio at scheduler
PLS playlist format support - Internet radio
Support for .wma, .wav, .mp3
Option to activate/deactivate source in the session
Scheduler: tab view - expert menu, option to activate/deactivate session
Function "copy" for Event in scheduler
Audio core - loopback from speakers like a session source
Option to play stuff from SD card, when there is lost of on-line connection
Restart button, SD card format button, synchronized button, test button - NsP flashes and beeps to identify itself
XML API Improvements - playlists, sessions, generated playlists, group of speakers, internet radio, file explorer
Authorization for XML API
HTTP API - Helios Family, Cisco support
Application
INFO panel - help with next steps
HELP in Control panel
New graphic look: session, NetSpeakes & zones, scheduler, Player application, SIP menu
------------------------------------------
------ NetStar v3.1.x changelog ----------
------------------------------------------
****************** IMPORTANT!!! **********************
After upgrade to firmware 3.1.x:
- BLF will be used for users (not stations)
- Autoclip routing will be used for SMS and calls together
- Free minutes are used only for ports marked as "Call on virtual port is accounted"
- Routers are accepting + as a part of number
- .NET Framework 4 needed (it will be automatically installed)
- NS Admin will create a copy of PBX tree from older NS Admin versions only ones
------------------------------------------------------
************************************************************************************************************************
**** Firmware 3.1.8 ****
new features:
- traditional voicemail (messages are stored on MMC card, or external harddrive)
- bulk SMS from NS Assistent or NS Tray icon
- SIP provisioning for IP Well VP503
- MS LYNC 2010 (TCP-UDP conversion)
improvements of NS assistant:
- renaming an extension in Assistent
- VoiceMail in wizzard (automatic router creation)
************************************************************************************************************************
**** Firmware 3.1.7 ****
Nové vlastnosti:
- Roouting table - possibility of static routing
- new Switch card with 4PRI ports support
NS Admin improvements:
- Bundles - possibility "let ring the last call" repaired uncorrected behaviour
- "PBX state" menu was edited
- edited taking over call from the queue
NS Assistant improvements
- possibility of configuration WELL VP-2009
************************************************************************************************************************
**** Firmware 3.1.6 ****
VERZION was NOT RELEASED
************************************************************************************************************************
**** Firmware 3.1.5 ****
NS Assistant improvements
- fix for recorded files in wav format
NS Admin improvements:
- Status bar for: service mode, licence, Disable inc. call mode, HW settings..
Improvements:
- UMTS improvements, optimization of communication, Set Audio Profile before the call,
************************************************************************************************************************
**** Firmware 3.1.4 ****
New features:
- Improvements in SIP provisioning
NS Admin improvements:
- In NS Admin tool repaired hazard state with colision in access codes of conference rooms
************************************************************************************************************************
**** Firmware 3.1.3 ****
New features:
NS Admin improvements:
- Object can be deleted by pressing "DELETE"
************************************************************************************************************************
**** Firmware 3.1.2 ****
New features:
NS Admin improvements:
- During deleting Complex router there was an error message - now fixed
************************************************************************************************************************
**** Firmware 3.1.1 ****
New features:
- NEW OBJECT Switch router - possibility to affect the routing path based on DTMF or from Assistant
- Support for 64 channel VoIP card
- Reset after preset count of calls on UMTS cards - globaly or separately for each card
- T38 improvements and changes. SIP FAX
NS Admin improvements:
- Global data - Progree tones - Tab - Tones- Congestio: Action of Tone, changes from selected value 425 Hz to Silence after saving - corrected
- Global data - Sheduled tasks - improvements (Remove all, editable tasks)
- In case of the process of saving database consist of some time - consuming procedures -there is progress bar available
- User progress upload by *56 changes fixed
- Several bugs fixed
NS Assistant improvements
- Redirection settings for the group in Assistent
- Possibility of control Switch Router in NS Assistent
- Automatic profile switching in NS tray icon
- Modification of labels in the window for Tray icon download
- Add Call Forwarding settings for the group
- corrected total count of free minutes and SMS
- Possibility of restart SIP terminals from Assistant
************************************************************************************************************************
**** Firmware 3.1.0 ****
New features:
- RTCP enabled
- New sheduler for NsAdmin
- Call slots for cornet phones. If there is a queue settuped, you can whitch between calls in the queue by pressing button.
- Starpoint 40T - it is possible to see caller´s id in waiting in queue for each call slot
- Starpoint 30T support
- Scheduler - it is possible to schedule these actions: Restart of PBX, Restart of UMTS cards, Sedning keep alive messages, Configuration backup
- New switch card with up to 4 E1 ports support ( 1011008Q , 1011008E )
- Provisioning for 2N IP phones
- 2N IP phones BLF support
- Queues for bundle
- New routing object: Status control
- Maximum call length
- Busy tone detection for instalations in Israel
- DTMF detection profile
- INTERCOM for 2N IP phones
- User settings of BLF for 2N IP phones: Users can setup BLF from 2N Netstar assistant
- Missed calls indicator: There is no missed call indication on 2N IP phones if answered call was routed to ring group or bundle with strategy "all"
- Jitter buffer settings: it is possible to setup more parameters for Jitter buffer
- New firmware for VoIP card (Surf 7_0_1_1)
- Support for iLBC 30 ms
- New possibilities of intervals for reloading free minutes and SMS
- AOC to DSS1: NetStar can send tarif pulses to DSS1
- Codec transcoding support
Improvements:
- autoclip routing table for SMS and calls
- SMS callback: SMS can be defined with or without callback timeout
- Trace analyzer improvements: doubleclick at trace analyzer message will open proper message in trace
- Assistant menu for administrator improvements
- Free minutes overview in Assistant; it is possible to charge new free minutes
- Free minutes statistics for each user overview (for admin)
- Free minutes charging possibilities (days, weeks, whatever interval)
- Forward SMS button from NS Assistant
- Starpoint 40T speed optimalisation
- Recording to *.wav files
- Recording improvements; it is possible to setup various strategies to store files (FIFO, unlimited number of files)
- External HDD connection improvements; immunity against LAN drive outage
- Callback timeout improvements - you can use callback with/without timeout
NS Admin improvements:
- Default parameters for group settings
- Direct link from station settings to Stack
- Actual ports usage and hardware configuration print
- Port list improvements for shorting of ports
- Comment field for each line in router
- PBX tree improvements - it shows the last connected version of NS and the last downloaded db version
- New menu for alerting DISA
- Password saving during connecting to the device
- Support for CTRL+F
- Support for keys Ins, Del
- CPU serial number shown in menu license
- Call Analyzer improvements; double click support for each message
- SIP proxy window, Optimalization for list of shown terminals
- New dialog for adding a new user
------ NetStar v3.1.x changelog ----------
------------------------------------------
****************** IMPORTANT!!! **********************
After upgrade to firmware 3.1.x:
- BLF will be used for users (not stations)
- Autoclip routing will be used for SMS and calls together
- Free minutes are used only for ports marked as "Call on virtual port is accounted"
- Routers are accepting + as a part of number
- .NET Framework 4 needed (it will be automatically installed)
- NS Admin will create a copy of PBX tree from older NS Admin versions only ones
------------------------------------------------------
************************************************************************************************************************
**** Firmware 3.1.8 ****
new features:
- traditional voicemail (messages are stored on MMC card, or external harddrive)
- bulk SMS from NS Assistent or NS Tray icon
- SIP provisioning for IP Well VP503
- MS LYNC 2010 (TCP-UDP conversion)
improvements of NS assistant:
- renaming an extension in Assistent
- VoiceMail in wizzard (automatic router creation)
************************************************************************************************************************
**** Firmware 3.1.7 ****
Nové vlastnosti:
- Roouting table - possibility of static routing
- new Switch card with 4PRI ports support
NS Admin improvements:
- Bundles - possibility "let ring the last call" repaired uncorrected behaviour
- "PBX state" menu was edited
- edited taking over call from the queue
NS Assistant improvements
- possibility of configuration WELL VP-2009
************************************************************************************************************************
**** Firmware 3.1.6 ****
VERZION was NOT RELEASED
************************************************************************************************************************
**** Firmware 3.1.5 ****
NS Assistant improvements
- fix for recorded files in wav format
NS Admin improvements:
- Status bar for: service mode, licence, Disable inc. call mode, HW settings..
Improvements:
- UMTS improvements, optimization of communication, Set Audio Profile before the call,
************************************************************************************************************************
**** Firmware 3.1.4 ****
New features:
- Improvements in SIP provisioning
NS Admin improvements:
- In NS Admin tool repaired hazard state with colision in access codes of conference rooms
************************************************************************************************************************
**** Firmware 3.1.3 ****
New features:
NS Admin improvements:
- Object can be deleted by pressing "DELETE"
************************************************************************************************************************
**** Firmware 3.1.2 ****
New features:
NS Admin improvements:
- During deleting Complex router there was an error message - now fixed
************************************************************************************************************************
**** Firmware 3.1.1 ****
New features:
- NEW OBJECT Switch router - possibility to affect the routing path based on DTMF or from Assistant
- Support for 64 channel VoIP card
- Reset after preset count of calls on UMTS cards - globaly or separately for each card
- T38 improvements and changes. SIP FAX
NS Admin improvements:
- Global data - Progree tones - Tab - Tones- Congestio: Action of Tone, changes from selected value 425 Hz to Silence after saving - corrected
- Global data - Sheduled tasks - improvements (Remove all, editable tasks)
- In case of the process of saving database consist of some time - consuming procedures -there is progress bar available
- User progress upload by *56 changes fixed
- Several bugs fixed
NS Assistant improvements
- Redirection settings for the group in Assistent
- Possibility of control Switch Router in NS Assistent
- Automatic profile switching in NS tray icon
- Modification of labels in the window for Tray icon download
- Add Call Forwarding settings for the group
- corrected total count of free minutes and SMS
- Possibility of restart SIP terminals from Assistant
************************************************************************************************************************
**** Firmware 3.1.0 ****
New features:
- RTCP enabled
- New sheduler for NsAdmin
- Call slots for cornet phones. If there is a queue settuped, you can whitch between calls in the queue by pressing button.
- Starpoint 40T - it is possible to see caller´s id in waiting in queue for each call slot
- Starpoint 30T support
- Scheduler - it is possible to schedule these actions: Restart of PBX, Restart of UMTS cards, Sedning keep alive messages, Configuration backup
- New switch card with up to 4 E1 ports support ( 1011008Q , 1011008E )
- Provisioning for 2N IP phones
- 2N IP phones BLF support
- Queues for bundle
- New routing object: Status control
- Maximum call length
- Busy tone detection for instalations in Israel
- DTMF detection profile
- INTERCOM for 2N IP phones
- User settings of BLF for 2N IP phones: Users can setup BLF from 2N Netstar assistant
- Missed calls indicator: There is no missed call indication on 2N IP phones if answered call was routed to ring group or bundle with strategy "all"
- Jitter buffer settings: it is possible to setup more parameters for Jitter buffer
- New firmware for VoIP card (Surf 7_0_1_1)
- Support for iLBC 30 ms
- New possibilities of intervals for reloading free minutes and SMS
- AOC to DSS1: NetStar can send tarif pulses to DSS1
- Codec transcoding support
Improvements:
- autoclip routing table for SMS and calls
- SMS callback: SMS can be defined with or without callback timeout
- Trace analyzer improvements: doubleclick at trace analyzer message will open proper message in trace
- Assistant menu for administrator improvements
- Free minutes overview in Assistant; it is possible to charge new free minutes
- Free minutes statistics for each user overview (for admin)
- Free minutes charging possibilities (days, weeks, whatever interval)
- Forward SMS button from NS Assistant
- Starpoint 40T speed optimalisation
- Recording to *.wav files
- Recording improvements; it is possible to setup various strategies to store files (FIFO, unlimited number of files)
- External HDD connection improvements; immunity against LAN drive outage
- Callback timeout improvements - you can use callback with/without timeout
NS Admin improvements:
- Default parameters for group settings
- Direct link from station settings to Stack
- Actual ports usage and hardware configuration print
- Port list improvements for shorting of ports
- Comment field for each line in router
- PBX tree improvements - it shows the last connected version of NS and the last downloaded db version
- New menu for alerting DISA
- Password saving during connecting to the device
- Support for CTRL+F
- Support for keys Ins, Del
- CPU serial number shown in menu license
- Call Analyzer improvements; double click support for each message
- SIP proxy window, Optimalization for list of shown terminals
- New dialog for adding a new user
------------------------------------------
------ NetStar v3.0.x changelog ----------
------------------------------------------
****************** IMPORTANT!!! **********************
After upgrade to firmware 3.0.x from 2.x.x
- For sending voicemail to e-mail and for sending e-mails to user: You have to create a station type e-mail and setup FROM PORT outing
- Call forwarding is not possible to setup for stations - only for users
------------------------------------------------------
*** Firmware 3.0.15 ***
Improvements:
- maddr atribute processing for better interconnection with Microsoft OCS/Lync
- CO line electric current limitation improvement
Fixed problems:
- Autoclip routing didn´t work if there was settuped "Keep number type of Incoming CLIP" as "Replace unknown" on Virtual port
- Memory and performance optimalization. Under full load there were no messages played
*** Firmware 3.0.14 ***
Improvements:
- support of ISDN CONNECT_ACK
Fixed problems:
- wrong format of wav file when backup function was used in NS
- SNMP v3 support
- Customized message for voicemail could be played two times
- NS Admin wizard = changed default HW profile
- T38 FAX channel alocation (500 Invalid Media Parameters)
- Calee identification could be changed during routing through the ring table
*** Firmware 3.0.13 ***
Improvements:
- ASSISTANT - more possibilities to find the record
- Changes for CO line [default Impedance,overvoltage protection]
- Default: Busy Tone Israel
- DTMF det. profile
Fixed problems:
- DSP Issue, Can fix problems: recording, conference, memory. . .
- Progress is not deleted after recording new one
-
*** Firmware 3.0.12 ***
Improvements:
- memory monitoring, Assistant memory optimalization, more information in the “bug” packages
Fixed problems:
- Recording could stop if TAPI dialling is used
- Incorect tones fall down hierarchy and priority
- Record route in SIP - NS was not sending all parameters
- Audio in AUX port after more calls could stop
- UMTS module reset - if sms at no answer and a call was sended together
*** Firmware 3.0.11 ***
Improvements:
- Changes for Default IN/Default OUT parameters - tone settings
*** Firmware 3.0.10 ***
Improvements:
- sheduled UMTS restart / PBX restart
- PC Operator - support of dialed number in queue (you can see what number was dialled before entering the queue)
Fixed problems:
- ISDN modem changes. Different chip is used
- UMTS card boot fix. Unsupported baud rate.
- Add new timeout for answer in each transaction according RFC RFC-3261. Default value 200s.
- Call recording fix. (call was not recorded if T38 was switched ON)
- T38 – fix for tone detection. Problem if recording and t38 was enabled together.
- CO Line fix. (co line can be stuck if it is a part of bundle configuration)
- Cornet display history (Fix for dialed number after call transfer)
*** Firmware 3.0.9 ***
Improvements:
- New Jitter Buffer for SIP
Fixed problems:
- Fix for DNS server
- 9# support for ME mode
- CO Line FIX
*** Firmware 3.0.8 ***
Improvements:
- Trusted IP addresses on SIP trunks – to protect NS from hacker´s attacks
- Free minutes settings
Fixed problems:
- CO line problem, busy tone detection
- Fix for UMTS card. Boot problem.
- GSM not allowed logout
- NS restarts after changing profile
*** Firmware 3.0.7 ***
Improvements:
- Trusted IP addresses on SIP trunks – to protect NS from hacker´s attacks
Fixed problems:
- Call to alerting disa from bundle causes routing to next row
- Forwarding has influence on paramer "wait with queue". [RING TABLE]
- NS crashes when using the service "DTMF to CTI" after DISA
- Bad order of ringing extensions in Cyclic bundle
- The parsing of time stamp for call recording and incoming SMS in the Internal Assistant is not showing correctly
*** Firmware 3.0.6 ***
Fixed problems:
- Critical memory leak
- Missing AOC record if user has forwarding activated
- Reset when user changes profile
- Service Unavailable after Reinvite with T.38
- Calling party number - octet 3a
- Incoming hold clip for external numbers
- UMTS audio parameters settings
- fix for "hold clip" func.
*** Firmware 3.0.5 ***
- Missing AOC record if user has forwarding activated
- Service Unavailable after Reinvite with T.38
*** Firmware 3.0.4 ***
Improvements:
- Row copy to all colomns (in a router or Id tab)
Fixed problems:
- SIM card topping up by USSD
- T.38 support for CISCO (X-cap header)
- Labels printing issue in IE8
- Call transfer from ME extension on SIP issue
*** Firmware 3.0.3 ***
Improvements:
- SMS Call Back - max timeout [s,m,h] – you can specify exact time the system calls you back
- Assistant Server - Win 2008, Win 7 and Vista support (Apache 2.2)
- DSS1 synchronisation for NT ports
- P-Asserted-Identity option (important for CLIR calls over SIP)
- Cornet phone busy information in Event reporter
- Incoming hold clip for SIP phones
- Hang Up AT command pro Sierra Wirelless - AT+CHLD=0
- Extension number presentation during entering the conference room
Fixed problems:
- Complex Router default destination routing
- Presentation Restricted transmission in CLIP Router
- SMS at no answer not working if routed through DISA
- BRI Port didn't keep level 1 enable it's always down
- After changing user language from Assistant, properties aren´t set up
- “Prepare to print” button missing if the key modul s18 is connected to OpenStage T40
*** Firmware 3.0.2 ***
Improvements:
- Audio profile settings
- New progress for "Maintenance progress"
- New progress for "Reset Profile"
- Admin in Assistant can see recorded calls
- Diacritical marks support in SMTP server
- Admin in Assistant can see the owners of time conditions
Fixed problems:
- Fix of intercom on OpenStage T40 extender S18
- Fix of doubled extensions in combo boxes
- ACK not recognized by NS on SIP stack
*** Firmware 3.0.1 ***
Improvements:
- FORCE CLIP + new Display CLIP for bundles and ring groups (you can change presentation of caller if the call terminates in ring group or bundle)
- CTI - add HANG UP for SIP extensions
- Busy tone detection
Fixed problems:
- call transfer for SNOM
- SIP - Original caller number not work in transferred
- A Fix for DSP (CPU – Tone detection, DISA, DTMF)
- FIX for Database backup
**** Firmware 3.0.0 ****
New features:
- Call Recording + Assistant management
- Free minutes management
- Free SMS management
- UMTS board support
- SMTP/ SMTPD port (email to sms/ sms to email)
- Queue for user
- Support for Siemens OpenStage / OptiPoint
- Automatic backup DB
- Blinking LED when call to GSM
- Allocation strategy in bundle - By credit, ALL
- Repeat destinations in bundle
- Logout, login to position in bundle
- Cause object in bundle (you can specify causes which will be used for routing to another destination)
- NEW Complex routers + routing on progress info
- CLIR support / Automatic CLIR
- SIP load balancing via SRV[NAPTR]
- BTS info for GSM/UMTS
- MMC card support 512MB < 2GB
- Storage Manager for VoiceMail, Call Recording, Backup of DB
- Call prefix for each number / group to Assistant
- DHCP Server for SIP phones
Improvements:
- When station busy = user busy
- Binary port can be activated during ringing (switch on/off by ring)
- Emergency mode support (if no licence, it will still route emergency numbers to PSTN)
- Exception for Emergency numbers if GSM DID active
- COPY of Profile
- Time conditional to Identification table (different identification during day/night)
- Request-URI add (transport=udp;lr)
New deffault settings:
- Deffault out settings for ICT Enabled is YES
- VoIP Card - Firmware VER. 6.0.1.3 [fix FAX issue, DTMF detector issue]
- G729 ANEX B = NO (possibility to disable/deny ANEX B)
Fixed problems:
- ISDN BRI fixed problem (BRI + DSL modem)
- Fix: SIP terminals hold after entry into service or conference room
- Fix: FSK CLIP problem
------ NetStar v3.0.x changelog ----------
------------------------------------------
****************** IMPORTANT!!! **********************
After upgrade to firmware 3.0.x from 2.x.x
- For sending voicemail to e-mail and for sending e-mails to user: You have to create a station type e-mail and setup FROM PORT outing
- Call forwarding is not possible to setup for stations - only for users
------------------------------------------------------
*** Firmware 3.0.15 ***
Improvements:
- maddr atribute processing for better interconnection with Microsoft OCS/Lync
- CO line electric current limitation improvement
Fixed problems:
- Autoclip routing didn´t work if there was settuped "Keep number type of Incoming CLIP" as "Replace unknown" on Virtual port
- Memory and performance optimalization. Under full load there were no messages played
*** Firmware 3.0.14 ***
Improvements:
- support of ISDN CONNECT_ACK
Fixed problems:
- wrong format of wav file when backup function was used in NS
- SNMP v3 support
- Customized message for voicemail could be played two times
- NS Admin wizard = changed default HW profile
- T38 FAX channel alocation (500 Invalid Media Parameters)
- Calee identification could be changed during routing through the ring table
*** Firmware 3.0.13 ***
Improvements:
- ASSISTANT - more possibilities to find the record
- Changes for CO line [default Impedance,overvoltage protection]
- Default: Busy Tone Israel
- DTMF det. profile
Fixed problems:
- DSP Issue, Can fix problems: recording, conference, memory. . .
- Progress is not deleted after recording new one
-
*** Firmware 3.0.12 ***
Improvements:
- memory monitoring, Assistant memory optimalization, more information in the “bug” packages
Fixed problems:
- Recording could stop if TAPI dialling is used
- Incorect tones fall down hierarchy and priority
- Record route in SIP - NS was not sending all parameters
- Audio in AUX port after more calls could stop
- UMTS module reset - if sms at no answer and a call was sended together
*** Firmware 3.0.11 ***
Improvements:
- Changes for Default IN/Default OUT parameters - tone settings
*** Firmware 3.0.10 ***
Improvements:
- sheduled UMTS restart / PBX restart
- PC Operator - support of dialed number in queue (you can see what number was dialled before entering the queue)
Fixed problems:
- ISDN modem changes. Different chip is used
- UMTS card boot fix. Unsupported baud rate.
- Add new timeout for answer in each transaction according RFC RFC-3261. Default value 200s.
- Call recording fix. (call was not recorded if T38 was switched ON)
- T38 – fix for tone detection. Problem if recording and t38 was enabled together.
- CO Line fix. (co line can be stuck if it is a part of bundle configuration)
- Cornet display history (Fix for dialed number after call transfer)
*** Firmware 3.0.9 ***
Improvements:
- New Jitter Buffer for SIP
Fixed problems:
- Fix for DNS server
- 9# support for ME mode
- CO Line FIX
*** Firmware 3.0.8 ***
Improvements:
- Trusted IP addresses on SIP trunks – to protect NS from hacker´s attacks
- Free minutes settings
Fixed problems:
- CO line problem, busy tone detection
- Fix for UMTS card. Boot problem.
- GSM not allowed logout
- NS restarts after changing profile
*** Firmware 3.0.7 ***
Improvements:
- Trusted IP addresses on SIP trunks – to protect NS from hacker´s attacks
Fixed problems:
- Call to alerting disa from bundle causes routing to next row
- Forwarding has influence on paramer "wait with queue". [RING TABLE]
- NS crashes when using the service "DTMF to CTI" after DISA
- Bad order of ringing extensions in Cyclic bundle
- The parsing of time stamp for call recording and incoming SMS in the Internal Assistant is not showing correctly
*** Firmware 3.0.6 ***
Fixed problems:
- Critical memory leak
- Missing AOC record if user has forwarding activated
- Reset when user changes profile
- Service Unavailable after Reinvite with T.38
- Calling party number - octet 3a
- Incoming hold clip for external numbers
- UMTS audio parameters settings
- fix for "hold clip" func.
*** Firmware 3.0.5 ***
- Missing AOC record if user has forwarding activated
- Service Unavailable after Reinvite with T.38
*** Firmware 3.0.4 ***
Improvements:
- Row copy to all colomns (in a router or Id tab)
Fixed problems:
- SIM card topping up by USSD
- T.38 support for CISCO (X-cap header)
- Labels printing issue in IE8
- Call transfer from ME extension on SIP issue
*** Firmware 3.0.3 ***
Improvements:
- SMS Call Back - max timeout [s,m,h] – you can specify exact time the system calls you back
- Assistant Server - Win 2008, Win 7 and Vista support (Apache 2.2)
- DSS1 synchronisation for NT ports
- P-Asserted-Identity option (important for CLIR calls over SIP)
- Cornet phone busy information in Event reporter
- Incoming hold clip for SIP phones
- Hang Up AT command pro Sierra Wirelless - AT+CHLD=0
- Extension number presentation during entering the conference room
Fixed problems:
- Complex Router default destination routing
- Presentation Restricted transmission in CLIP Router
- SMS at no answer not working if routed through DISA
- BRI Port didn't keep level 1 enable it's always down
- After changing user language from Assistant, properties aren´t set up
- “Prepare to print” button missing if the key modul s18 is connected to OpenStage T40
*** Firmware 3.0.2 ***
Improvements:
- Audio profile settings
- New progress for "Maintenance progress"
- New progress for "Reset Profile"
- Admin in Assistant can see recorded calls
- Diacritical marks support in SMTP server
- Admin in Assistant can see the owners of time conditions
Fixed problems:
- Fix of intercom on OpenStage T40 extender S18
- Fix of doubled extensions in combo boxes
- ACK not recognized by NS on SIP stack
*** Firmware 3.0.1 ***
Improvements:
- FORCE CLIP + new Display CLIP for bundles and ring groups (you can change presentation of caller if the call terminates in ring group or bundle)
- CTI - add HANG UP for SIP extensions
- Busy tone detection
Fixed problems:
- call transfer for SNOM
- SIP - Original caller number not work in transferred
- A Fix for DSP (CPU – Tone detection, DISA, DTMF)
- FIX for Database backup
**** Firmware 3.0.0 ****
New features:
- Call Recording + Assistant management
- Free minutes management
- Free SMS management
- UMTS board support
- SMTP/ SMTPD port (email to sms/ sms to email)
- Queue for user
- Support for Siemens OpenStage / OptiPoint
- Automatic backup DB
- Blinking LED when call to GSM
- Allocation strategy in bundle - By credit, ALL
- Repeat destinations in bundle
- Logout, login to position in bundle
- Cause object in bundle (you can specify causes which will be used for routing to another destination)
- NEW Complex routers + routing on progress info
- CLIR support / Automatic CLIR
- SIP load balancing via SRV[NAPTR]
- BTS info for GSM/UMTS
- MMC card support 512MB < 2GB
- Storage Manager for VoiceMail, Call Recording, Backup of DB
- Call prefix for each number / group to Assistant
- DHCP Server for SIP phones
Improvements:
- When station busy = user busy
- Binary port can be activated during ringing (switch on/off by ring)
- Emergency mode support (if no licence, it will still route emergency numbers to PSTN)
- Exception for Emergency numbers if GSM DID active
- COPY of Profile
- Time conditional to Identification table (different identification during day/night)
- Request-URI add (transport=udp;lr)
New deffault settings:
- Deffault out settings for ICT Enabled is YES
- VoIP Card - Firmware VER. 6.0.1.3 [fix FAX issue, DTMF detector issue]
- G729 ANEX B = NO (possibility to disable/deny ANEX B)
Fixed problems:
- ISDN BRI fixed problem (BRI + DSL modem)
- Fix: SIP terminals hold after entry into service or conference room
- Fix: FSK CLIP problem
2N® OfficeRoute - firmware
Release Notes
OFR-2-3-20 2013-03-15
* SIP - option to setup any port for SIP proxy (it does not have to be 5060 only)
* SMS - option to receive messageges automatically over SMTP
OFR-2-3-19 2012-09-21
* SMS - You can turn on sms following the order in which messages are sent exactly in the order in which they came (can reduce throughput)
* SIP - option to disable header P-asserted-Identity and P-Preferred-Identity
* OFR - support of modules MC55i-w
* FIXED - hanging a call during the second incoming call to the module Sierra (UMTS module)
OFR-2-3-18 2012-01-23
* FIXED: MicroSD card couldn't be read when missing the partition table
* SMS - Notification of a near-to-full SMS database; automatical deleting old SMSs according to the settings
* SMS - validity period of sent SMSs increased to maximum according to the network (time-to-live in the net). Previously it was 10 minutes.
OFR-2-3-17 2011-12-23
* FIXED - CLIP routing - memory leak !!!
* SIP - branch is not matched in the CANCEL message (SIP proxy changes the original branch from INVITE and CANCEL has been ignored)
* FIXED - SMS CLIP routing
OFR-2-3-16 2011-10-10
• SIP - DTMF transfer by SIP INFO method supported (set in the SIP line menu)
• CLIP Routing in LCR - call/SMS routed according to the calling party number
• Tarrifs - Weekly limit for calls/SMSs
• FIXED - Accounting files (CDRs) had 0 length after the new file has been created (on the 1st day of the month)
• FIXED - Network settings of UMTS modul not displayed correctly
• New UserGuide 1.8.2 (new features, LCR priority settings explained thoroughly!)
OFR-2-3-13 2011-03-09
• Network type selection on UMTS module
• Restart of UMTS module after the SIM card exchange
• SIP proxy accessible from UMTS (till now only over Ethernet port) - limitation: with public IP address only
• Firewall active on all interfaces (till now only on ethernet port) !!!
• Wizard deletes the SIP line for VoIP provider, if not used
• The maximal numbur od concurent calls could be set in the SIP line menu
• Incoming INVITE is ignored if the source IP address doesn't match to one set in SIP Server parameter of the SIP line
• U nově vložených SIM je defaultně zakázán roaming
• H.323 - StatusMsg supported
• FIXED - problem of setting voice colume in some UMTS modules
• FIXED - Network restriction has been checked in Cinterion modules only once, after the OFR switch-on
OFR-2-3-11 2010-11-12
• If a reboot of happens during receiving of a long SMS (divided in a few parts), all parts will be anyway concatenated
• Configuration restore - by default license in the device will not be rewritten
• SMSs in the Failed folder could be signed to be sent again
• Fixed – in LCR normalisation, the Caller incoming setting has been switched to Called outgoing when that record has been opened for editing again
• POP3 server - longer buffer for long SMSs
• Fixed – In the case of multi-part SMSs, normalisation has been done only for the first part
Release Notes
OFR-2-3-20 2013-03-15
* SIP - option to setup any port for SIP proxy (it does not have to be 5060 only)
* SMS - option to receive messageges automatically over SMTP
OFR-2-3-19 2012-09-21
* SMS - You can turn on sms following the order in which messages are sent exactly in the order in which they came (can reduce throughput)
* SIP - option to disable header P-asserted-Identity and P-Preferred-Identity
* OFR - support of modules MC55i-w
* FIXED - hanging a call during the second incoming call to the module Sierra (UMTS module)
OFR-2-3-18 2012-01-23
* FIXED: MicroSD card couldn't be read when missing the partition table
* SMS - Notification of a near-to-full SMS database; automatical deleting old SMSs according to the settings
* SMS - validity period of sent SMSs increased to maximum according to the network (time-to-live in the net). Previously it was 10 minutes.
OFR-2-3-17 2011-12-23
* FIXED - CLIP routing - memory leak !!!
* SIP - branch is not matched in the CANCEL message (SIP proxy changes the original branch from INVITE and CANCEL has been ignored)
* FIXED - SMS CLIP routing
OFR-2-3-16 2011-10-10
• SIP - DTMF transfer by SIP INFO method supported (set in the SIP line menu)
• CLIP Routing in LCR - call/SMS routed according to the calling party number
• Tarrifs - Weekly limit for calls/SMSs
• FIXED - Accounting files (CDRs) had 0 length after the new file has been created (on the 1st day of the month)
• FIXED - Network settings of UMTS modul not displayed correctly
• New UserGuide 1.8.2 (new features, LCR priority settings explained thoroughly!)
OFR-2-3-13 2011-03-09
• Network type selection on UMTS module
• Restart of UMTS module after the SIM card exchange
• SIP proxy accessible from UMTS (till now only over Ethernet port) - limitation: with public IP address only
• Firewall active on all interfaces (till now only on ethernet port) !!!
• Wizard deletes the SIP line for VoIP provider, if not used
• The maximal numbur od concurent calls could be set in the SIP line menu
• Incoming INVITE is ignored if the source IP address doesn't match to one set in SIP Server parameter of the SIP line
• U nově vložených SIM je defaultně zakázán roaming
• H.323 - StatusMsg supported
• FIXED - problem of setting voice colume in some UMTS modules
• FIXED - Network restriction has been checked in Cinterion modules only once, after the OFR switch-on
OFR-2-3-11 2010-11-12
• If a reboot of happens during receiving of a long SMS (divided in a few parts), all parts will be anyway concatenated
• Configuration restore - by default license in the device will not be rewritten
• SMSs in the Failed folder could be signed to be sent again
• Fixed – in LCR normalisation, the Caller incoming setting has been switched to Called outgoing when that record has been opened for editing again
• POP3 server - longer buffer for long SMSs
• Fixed – In the case of multi-part SMSs, normalisation has been done only for the first part
2N® OfficeRoute - firmware
Release Notes
01.10.2012
OFR-2-3-19 2012-09-21
* SMS - You can turn on sms following the order in which messages are sent exactly in the order in which they came (can reduce throughput)
* SIP - option to disable header P-asserted-Identity and P-Preferred-Identity
* OFR - support of modules MC55i-w
* FIXED - hanging a call during the second incoming call to the module Sierra (UMTS module)
OFR-2-3-18 2012-01-23
* FIXED: MicroSD card couldn't be read when missing the partition table
* SMS - Notification of a near-to-full SMS database; automatical deleting old SMSs according to the settings
* SMS - validity period of sent SMSs increased to maximum according to the network (time-to-live in the net). Previously it was 10 minutes.
OFR-2-3-17 2011-12-23
* FIXED - CLIP routing - memory leak !!!
* SIP - branch is not matched in the CANCEL message (SIP proxy changes the original branch from INVITE and CANCEL has been ignored)
* FIXED - SMS CLIP routing
OFR-2-3-16 2011-10-10
• SIP - DTMF transfer by SIP INFO method supported (set in the SIP line menu)
• CLIP Routing in LCR - call/SMS routed according to the calling party number
• Tarrifs - Weekly limit for calls/SMSs
• FIXED - Accounting files (CDRs) had 0 length after the new file has been created (on the 1st day of the month)
• FIXED - Network settings of UMTS modul not displayed correctly
• New UserGuide 1.8.2 (new features, LCR priority settings explained thoroughly!)
OFR-2-3-13 2011-03-09
• Network type selection on UMTS module
• Restart of UMTS module after the SIM card exchange
• SIP proxy accessible from UMTS (till now only over Ethernet port) - limitation: with public IP address only
• Firewall active on all interfaces (till now only on ethernet port) !!!
• Wizard deletes the SIP line for VoIP provider, if not used
• The maximal numbur od concurent calls could be set in the SIP line menu
• Incoming INVITE is ignored if the source IP address doesn't match to one set in SIP Server parameter of the SIP line
• U nově vložených SIM je defaultně zakázán roaming
• H.323 - StatusMsg supported
• FIXED - problem of setting voice colume in some UMTS modules
• FIXED - Network restriction has been checked in Cinterion modules only once, after the OFR switch-on
OFR-2-3-11 2010-11-12
• If a reboot of happens during receiving of a long SMS (divided in a few parts), all parts will be anyway concatenated
• Configuration restore - by default license in the device will not be rewritten
• SMSs in the Failed folder could be signed to be sent again
• Fixed – in LCR normalisation, the Caller incoming setting has been switched to Called outgoing when that record has been opened for editing again
• POP3 server - longer buffer for long SMSs
• Fixed – In the case of multi-part SMSs, normalisation has been done only for the first part
Release Notes
01.10.2012
OFR-2-3-19 2012-09-21
* SMS - You can turn on sms following the order in which messages are sent exactly in the order in which they came (can reduce throughput)
* SIP - option to disable header P-asserted-Identity and P-Preferred-Identity
* OFR - support of modules MC55i-w
* FIXED - hanging a call during the second incoming call to the module Sierra (UMTS module)
OFR-2-3-18 2012-01-23
* FIXED: MicroSD card couldn't be read when missing the partition table
* SMS - Notification of a near-to-full SMS database; automatical deleting old SMSs according to the settings
* SMS - validity period of sent SMSs increased to maximum according to the network (time-to-live in the net). Previously it was 10 minutes.
OFR-2-3-17 2011-12-23
* FIXED - CLIP routing - memory leak !!!
* SIP - branch is not matched in the CANCEL message (SIP proxy changes the original branch from INVITE and CANCEL has been ignored)
* FIXED - SMS CLIP routing
OFR-2-3-16 2011-10-10
• SIP - DTMF transfer by SIP INFO method supported (set in the SIP line menu)
• CLIP Routing in LCR - call/SMS routed according to the calling party number
• Tarrifs - Weekly limit for calls/SMSs
• FIXED - Accounting files (CDRs) had 0 length after the new file has been created (on the 1st day of the month)
• FIXED - Network settings of UMTS modul not displayed correctly
• New UserGuide 1.8.2 (new features, LCR priority settings explained thoroughly!)
OFR-2-3-13 2011-03-09
• Network type selection on UMTS module
• Restart of UMTS module after the SIM card exchange
• SIP proxy accessible from UMTS (till now only over Ethernet port) - limitation: with public IP address only
• Firewall active on all interfaces (till now only on ethernet port) !!!
• Wizard deletes the SIP line for VoIP provider, if not used
• The maximal numbur od concurent calls could be set in the SIP line menu
• Incoming INVITE is ignored if the source IP address doesn't match to one set in SIP Server parameter of the SIP line
• U nově vložených SIM je defaultně zakázán roaming
• H.323 - StatusMsg supported
• FIXED - problem of setting voice colume in some UMTS modules
• FIXED - Network restriction has been checked in Cinterion modules only once, after the OFR switch-on
OFR-2-3-11 2010-11-12
• If a reboot of happens during receiving of a long SMS (divided in a few parts), all parts will be anyway concatenated
• Configuration restore - by default license in the device will not be rewritten
• SMSs in the Failed folder could be signed to be sent again
• Fixed – in LCR normalisation, the Caller incoming setting has been switched to Called outgoing when that record has been opened for editing again
• POP3 server - longer buffer for long SMSs
• Fixed – In the case of multi-part SMSs, normalisation has been done only for the first part
2N® OfficeRoute - firmware
Release Notes
01.02.2012
OFR-2-3-18 2012-01-23
* FIXED: MicroSD card couldn't be read when missing the partition table
* SMS - Notification of a near-to-full SMS database; automatical deleting old SMSs according to the settings
* SMS - validity period of sent SMSs increased to maximum according to the network (time-to-live in the net). Previously it was 10 minutes.
OFR-2-3-17 2011-12-23
* FIXED - CLIP routing - memory leak !!!
* SIP - branch is not matched in the CANCEL message (SIP proxy changes the original branch from INVITE and CANCEL has been ignored)
* FIXED - SMS CLIP routing
OFR-2-3-16 2011-10-10
• SIP - DTMF transfer by SIP INFO method supported (set in the SIP line menu)
• CLIP Routing in LCR - call/SMS routed according to the calling party number
• Tarrifs - Weekly limit for calls/SMSs
• FIXED - Accounting files (CDRs) had 0 length after the new file has been created (on the 1st day of the month)
• FIXED - Network settings of UMTS modul not displayed correctly
• New UserGuide 1.8.2 (new features, LCR priority settings explained thoroughly!)
OFR-2-3-13 2011-03-09
• Network type selection on UMTS module
• Restart of UMTS module after the SIM card exchange
• SIP proxy accessible from UMTS (till now only over Ethernet port) - limitation: with public IP address only
• Firewall active on all interfaces (till now only on ethernet port) !!!
• Wizard deletes the SIP line for VoIP provider, if not used
• The maximal numbur od concurent calls could be set in the SIP line menu
• Incoming INVITE is ignored if the source IP address doesn't match to one set in SIP Server parameter of the SIP line
• U nově vložených SIM je defaultně zakázán roaming
• H.323 - StatusMsg supported
• FIXED - problem of setting voice colume in some UMTS modules
• FIXED - Network restriction has been checked in Cinterion modules only once, after the OFR switch-on
OFR-2-3-11 2010-11-12
• If a reboot of happens during receiving of a long SMS (divided in a few parts), all parts will be anyway concatenated
• Configuration restore - by default license in the device will not be rewritten
• SMSs in the Failed folder could be signed to be sent again
• Fixed – in LCR normalisation, the Caller incoming setting has been switched to Called outgoing when that record has been opened for editing again
• POP3 server - longer buffer for long SMSs
• Fixed – In the case of multi-part SMSs, normalisation has been done only for the first part
Release Notes
01.02.2012
OFR-2-3-18 2012-01-23
* FIXED: MicroSD card couldn't be read when missing the partition table
* SMS - Notification of a near-to-full SMS database; automatical deleting old SMSs according to the settings
* SMS - validity period of sent SMSs increased to maximum according to the network (time-to-live in the net). Previously it was 10 minutes.
OFR-2-3-17 2011-12-23
* FIXED - CLIP routing - memory leak !!!
* SIP - branch is not matched in the CANCEL message (SIP proxy changes the original branch from INVITE and CANCEL has been ignored)
* FIXED - SMS CLIP routing
OFR-2-3-16 2011-10-10
• SIP - DTMF transfer by SIP INFO method supported (set in the SIP line menu)
• CLIP Routing in LCR - call/SMS routed according to the calling party number
• Tarrifs - Weekly limit for calls/SMSs
• FIXED - Accounting files (CDRs) had 0 length after the new file has been created (on the 1st day of the month)
• FIXED - Network settings of UMTS modul not displayed correctly
• New UserGuide 1.8.2 (new features, LCR priority settings explained thoroughly!)
OFR-2-3-13 2011-03-09
• Network type selection on UMTS module
• Restart of UMTS module after the SIM card exchange
• SIP proxy accessible from UMTS (till now only over Ethernet port) - limitation: with public IP address only
• Firewall active on all interfaces (till now only on ethernet port) !!!
• Wizard deletes the SIP line for VoIP provider, if not used
• The maximal numbur od concurent calls could be set in the SIP line menu
• Incoming INVITE is ignored if the source IP address doesn't match to one set in SIP Server parameter of the SIP line
• U nově vložených SIM je defaultně zakázán roaming
• H.323 - StatusMsg supported
• FIXED - problem of setting voice colume in some UMTS modules
• FIXED - Network restriction has been checked in Cinterion modules only once, after the OFR switch-on
OFR-2-3-11 2010-11-12
• If a reboot of happens during receiving of a long SMS (divided in a few parts), all parts will be anyway concatenated
• Configuration restore - by default license in the device will not be rewritten
• SMSs in the Failed folder could be signed to be sent again
• Fixed – in LCR normalisation, the Caller incoming setting has been switched to Called outgoing when that record has been opened for editing again
• POP3 server - longer buffer for long SMSs
• Fixed – In the case of multi-part SMSs, normalisation has been done only for the first part
2N® OfficeRoute - firmware
Release Notes
23.12.2011
OFR-2-3-17 2011-12-23
* FIXED - CLIP routing - memory leak !!!
* SIP - branch is not matched in the CANCEL message (SIP proxy changes the original branch from INVITE and CANCEL has been ignored)
* FIXED - SMS CLIP routing
OFR-2-3-16 2011-10-10
• SIP - DTMF transfer by SIP INFO method supported (set in the SIP line menu)
• CLIP Routing in LCR - call/SMS routed according to the calling party number
• Tarrifs - Weekly limit for calls/SMSs
• FIXED - Accounting files (CDRs) had 0 length after the new file has been created (on the 1st day of the month)
• FIXED - Network settings of UMTS modul not displayed correctly
• New UserGuide 1.8.2 (new features, LCR priority settings explained thoroughly!)
OFR-2-3-13 2011-03-09
• Network type selection on UMTS module
• Restart of UMTS module after the SIM card exchange
• SIP proxy accessible from UMTS (till now only over Ethernet port) - limitation: with public IP address only
• Firewall active on all interfaces (till now only on ethernet port) !!!
• Wizard deletes the SIP line for VoIP provider, if not used
• The maximal numbur od concurent calls could be set in the SIP line menu
• Incoming INVITE is ignored if the source IP address doesn't match to one set in SIP Server parameter of the SIP line
• U nově vložených SIM je defaultně zakázán roaming
• H.323 - StatusMsg supported
• FIXED - problem of setting voice colume in some UMTS modules
• FIXED - Network restriction has been checked in Cinterion modules only once, after the OFR switch-on
OFR-2-3-11 2010-11-12
• If a reboot of happens during receiving of a long SMS (divided in a few parts), all parts will be anyway concatenated
• Configuration restore - by default license in the device will not be rewritten
• SMSs in the Failed folder could be signed to be sent again
• Fixed – in LCR normalisation, the Caller incoming setting has been switched to Called outgoing when that record has been opened for editing again
• POP3 server - longer buffer for long SMSs
• Fixed – In the case of multi-part SMSs, normalisation has been done only for the first part
Release Notes
23.12.2011
OFR-2-3-17 2011-12-23
* FIXED - CLIP routing - memory leak !!!
* SIP - branch is not matched in the CANCEL message (SIP proxy changes the original branch from INVITE and CANCEL has been ignored)
* FIXED - SMS CLIP routing
OFR-2-3-16 2011-10-10
• SIP - DTMF transfer by SIP INFO method supported (set in the SIP line menu)
• CLIP Routing in LCR - call/SMS routed according to the calling party number
• Tarrifs - Weekly limit for calls/SMSs
• FIXED - Accounting files (CDRs) had 0 length after the new file has been created (on the 1st day of the month)
• FIXED - Network settings of UMTS modul not displayed correctly
• New UserGuide 1.8.2 (new features, LCR priority settings explained thoroughly!)
OFR-2-3-13 2011-03-09
• Network type selection on UMTS module
• Restart of UMTS module after the SIM card exchange
• SIP proxy accessible from UMTS (till now only over Ethernet port) - limitation: with public IP address only
• Firewall active on all interfaces (till now only on ethernet port) !!!
• Wizard deletes the SIP line for VoIP provider, if not used
• The maximal numbur od concurent calls could be set in the SIP line menu
• Incoming INVITE is ignored if the source IP address doesn't match to one set in SIP Server parameter of the SIP line
• U nově vložených SIM je defaultně zakázán roaming
• H.323 - StatusMsg supported
• FIXED - problem of setting voice colume in some UMTS modules
• FIXED - Network restriction has been checked in Cinterion modules only once, after the OFR switch-on
OFR-2-3-11 2010-11-12
• If a reboot of happens during receiving of a long SMS (divided in a few parts), all parts will be anyway concatenated
• Configuration restore - by default license in the device will not be rewritten
• SMSs in the Failed folder could be signed to be sent again
• Fixed – in LCR normalisation, the Caller incoming setting has been switched to Called outgoing when that record has been opened for editing again
• POP3 server - longer buffer for long SMSs
• Fixed – In the case of multi-part SMSs, normalisation has been done only for the first part
2N® PBX Assistant O2Netcom / OMEGA Lite / OMEGA 48 – Release Notes
01.02.2011
1.05 K
• Compatibility between the default settings of buttons on the key phone OpenStage and firmware in OmegaLite.
1.03 C
• Emphasizing of Call Data Records in the History of Calls e.g calls that have been responded to etc
• Adding notes to Call Data Records in the History of Calls
• Two sizes of the phone display window, if there has been set not to display the whole SKIN of the phone
1.02 H
News:
• Fixed - dialing from the empty record in the call history
1.02 F
News:
• Connection to the XAPI server is automatically established when XAOI server is up.
• Setting of keys and printing of labels is available in the off-line mode too
1.02 C
News:
• Changes in short dial settings supported - related to the 2N® XAPI Server ver. 1.18D ( in the previous versions changes haven’t been accepted if the 2N® PBX Assistant was running)
01.02.2011
1.05 K
• Compatibility between the default settings of buttons on the key phone OpenStage and firmware in OmegaLite.
1.03 C
• Emphasizing of Call Data Records in the History of Calls e.g calls that have been responded to etc
• Adding notes to Call Data Records in the History of Calls
• Two sizes of the phone display window, if there has been set not to display the whole SKIN of the phone
1.02 H
News:
• Fixed - dialing from the empty record in the call history
1.02 F
News:
• Connection to the XAPI server is automatically established when XAOI server is up.
• Setting of keys and printing of labels is available in the off-line mode too
1.02 C
News:
• Changes in short dial settings supported - related to the 2N® XAPI Server ver. 1.18D ( in the previous versions changes haven’t been accepted if the 2N® PBX Assistant was running)
2N® Omega Lite / 2N® Omega 48 – Configuration Tool
Release Notes
01.02.2011
4.10 E
• Data.dia and Data.acc in Windows 7 (and Vista) are saved to the Documents/User/2N TELEKOMUNIKACE/Omega Program folder.
• The ISDN module firmware version checked. I fit is 17.02 or higher an upgrade is not enabled.
4.10
• Support of the firmware 4.10rev2 (see Release Notes of 4.10rev2)
• The new Configuration Tool manual ver. 1.9
4.08 D
• Support of the firmware 4.08rev7 (see Release Notes of 4.08rev7)
• The new Configuration Tool manual ver. 1.8
4.08 C
• Support of new functions in firmware 4.08, till revision 5
• Fixed – Message „List index out of bounds“ appeared when going out of the ISDN line settings menu (sometimes, after upgrade from older firmware versions)
• The new Configuration Tool manual ver. 1.7
4.06 V, 4.07 H
• Fixed – Message „List index out of bounds“ appeared when going out of the ISDN line settings menu (sometimes, after upgrade from older firmware versions)
4.06 U, 4.07G
• !!! Fixed important error !!! – Upgrade from versions older than 4.06 could be unsuccessful. PBX has been left in the service mode.
• Fixed - new IL modules (with support of higher voltage for CLIP) haven’t displayed correctly in menu Global data/Hardware
• Info: Change in the firmware upload procedure – first are loaded language packals and after that the rest of data.
4.05 Y
• Fixed - new IL modules (with support of higher voltage for CLIP) haven’t displayed correctly in menu Global data/Hardware
4.07 D
• Auto CLIP routing – settings – separate menu
• The Italian menu on key (system) phones selection supported
• New Configuration Tool manual – version 1.6
4.06 S (service puprposes)
• Fixed problem in remote management over dialup modems – If the call from remote management modem has been manually transferred to the internal modem in Omega, the connection could be cancelled from the calling party side.
• Fixed problem – The Short Dial data from versions 4.05 and earlier couldn’t be exported to version 4.06.
Release Notes
01.02.2011
4.10 E
• Data.dia and Data.acc in Windows 7 (and Vista) are saved to the Documents/User/2N TELEKOMUNIKACE/Omega Program folder.
• The ISDN module firmware version checked. I fit is 17.02 or higher an upgrade is not enabled.
4.10
• Support of the firmware 4.10rev2 (see Release Notes of 4.10rev2)
• The new Configuration Tool manual ver. 1.9
4.08 D
• Support of the firmware 4.08rev7 (see Release Notes of 4.08rev7)
• The new Configuration Tool manual ver. 1.8
4.08 C
• Support of new functions in firmware 4.08, till revision 5
• Fixed – Message „List index out of bounds“ appeared when going out of the ISDN line settings menu (sometimes, after upgrade from older firmware versions)
• The new Configuration Tool manual ver. 1.7
4.06 V, 4.07 H
• Fixed – Message „List index out of bounds“ appeared when going out of the ISDN line settings menu (sometimes, after upgrade from older firmware versions)
4.06 U, 4.07G
• !!! Fixed important error !!! – Upgrade from versions older than 4.06 could be unsuccessful. PBX has been left in the service mode.
• Fixed - new IL modules (with support of higher voltage for CLIP) haven’t displayed correctly in menu Global data/Hardware
• Info: Change in the firmware upload procedure – first are loaded language packals and after that the rest of data.
4.05 Y
• Fixed - new IL modules (with support of higher voltage for CLIP) haven’t displayed correctly in menu Global data/Hardware
4.07 D
• Auto CLIP routing – settings – separate menu
• The Italian menu on key (system) phones selection supported
• New Configuration Tool manual – version 1.6
4.06 S (service puprposes)
• Fixed problem in remote management over dialup modems – If the call from remote management modem has been manually transferred to the internal modem in Omega, the connection could be cancelled from the calling party side.
• Fixed problem – The Short Dial data from versions 4.05 and earlier couldn’t be exported to version 4.06.
2N® Omega Lite / 2N® Omega 48 – Configuration Tool
Release Notes
14.09.2010
4.10
• Support of the firmware 4.10rev2 (see Release Notes of 4.10rev2)
• The new Configuration Tool manual ver. 1.9
4.08 D
• Support of the firmware 4.08rev7 (see Release Notes of 4.08rev7)
• The new Configuration Tool manual ver. 1.8
4.08 C
• Support of new functions in firmware 4.08, till revision 5
• Fixed – Message „List index out of bounds“ appeared when going out of the ISDN line settings menu (sometimes, after upgrade from older firmware versions)
• The new Configuration Tool manual ver. 1.7
4.06 V, 4.07 H
• Fixed – Message „List index out of bounds“ appeared when going out of the ISDN line settings menu (sometimes, after upgrade from older firmware versions)
4.06 U, 4.07G
• !!! Fixed important error !!! – Upgrade from versions older than 4.06 could be unsuccessful. PBX has been left in the service mode.
• Fixed - new IL modules (with support of higher voltage for CLIP) haven’t displayed correctly in menu Global data/Hardware
• Info: Change in the firmware upload procedure – first are loaded language packals and after that the rest of data.
4.05 Y
• Fixed - new IL modules (with support of higher voltage for CLIP) haven’t displayed correctly in menu Global data/Hardware
4.07 D
• Auto CLIP routing – settings – separate menu
• The Italian menu on key (system) phones selection supported
• New Configuration Tool manual – version 1.6
4.06 S (service puprposes)
• Fixed problem in remote management over dialup modems – If the call from remote management modem has been manually transferred to the internal modem in Omega, the connection could be cancelled from the calling party side.
• Fixed problem – The Short Dial data from versions 4.05 and earlier couldn’t be exported to version 4.06.
Release Notes
14.09.2010
4.10
• Support of the firmware 4.10rev2 (see Release Notes of 4.10rev2)
• The new Configuration Tool manual ver. 1.9
4.08 D
• Support of the firmware 4.08rev7 (see Release Notes of 4.08rev7)
• The new Configuration Tool manual ver. 1.8
4.08 C
• Support of new functions in firmware 4.08, till revision 5
• Fixed – Message „List index out of bounds“ appeared when going out of the ISDN line settings menu (sometimes, after upgrade from older firmware versions)
• The new Configuration Tool manual ver. 1.7
4.06 V, 4.07 H
• Fixed – Message „List index out of bounds“ appeared when going out of the ISDN line settings menu (sometimes, after upgrade from older firmware versions)
4.06 U, 4.07G
• !!! Fixed important error !!! – Upgrade from versions older than 4.06 could be unsuccessful. PBX has been left in the service mode.
• Fixed - new IL modules (with support of higher voltage for CLIP) haven’t displayed correctly in menu Global data/Hardware
• Info: Change in the firmware upload procedure – first are loaded language packals and after that the rest of data.
4.05 Y
• Fixed - new IL modules (with support of higher voltage for CLIP) haven’t displayed correctly in menu Global data/Hardware
4.07 D
• Auto CLIP routing – settings – separate menu
• The Italian menu on key (system) phones selection supported
• New Configuration Tool manual – version 1.6
4.06 S (service puprposes)
• Fixed problem in remote management over dialup modems – If the call from remote management modem has been manually transferred to the internal modem in Omega, the connection could be cancelled from the calling party side.
• Fixed problem – The Short Dial data from versions 4.05 and earlier couldn’t be exported to version 4.06.
2N® Omega Lite / 2N® Omega 48 – Configuration Tool
Release Notes
30.05.2010
4.08 D
• Support of the firmware 4.08rev7 (see Release Notes of 4.08rev7)
• The new Configuration Tool manual ver. 1.8
4.08 C
• Support of new functions in firmware 4.08, till revision 5
• Fixed – Message „List index out of bounds“ appeared when going out of the ISDN line settings menu (sometimes, after upgrade from older firmware versions)
• The new Configuration Tool manual ver. 1.7
4.06 V, 4.07 H
• Fixed – Message „List index out of bounds“ appeared when going out of the ISDN line settings menu (sometimes, after upgrade from older firmware versions)
4.06 U, 4.07G
• !!! Fixed important error !!! – Upgrade from versions older than 4.06 could be unsuccessful. PBX has been left in the service mode.
• Fixed - new IL modules (with support of higher voltage for CLIP) haven’t displayed correctly in menu Global data/Hardware
• Info: Change in the firmware upload procedure – first are loaded language packals and after that the rest of data.
4.05 Y
• Fixed - new IL modules (with support of higher voltage for CLIP) haven’t displayed correctly in menu Global data/Hardware
4.07 D
• Auto CLIP routing – settings – separate menu
• The Italian menu on key (system) phones selection supported
• New Configuration Tool manual – version 1.6
4.06 S (service puprposes)
• Fixed problem in remote management over dialup modems – If the call from remote management modem has been manually transferred to the internal modem in Omega, the connection could be cancelled from the calling party side.
• Fixed problem – The Short Dial data from versions 4.05 and earlier couldn’t be exported to version 4.06.
Release Notes
30.05.2010
4.08 D
• Support of the firmware 4.08rev7 (see Release Notes of 4.08rev7)
• The new Configuration Tool manual ver. 1.8
4.08 C
• Support of new functions in firmware 4.08, till revision 5
• Fixed – Message „List index out of bounds“ appeared when going out of the ISDN line settings menu (sometimes, after upgrade from older firmware versions)
• The new Configuration Tool manual ver. 1.7
4.06 V, 4.07 H
• Fixed – Message „List index out of bounds“ appeared when going out of the ISDN line settings menu (sometimes, after upgrade from older firmware versions)
4.06 U, 4.07G
• !!! Fixed important error !!! – Upgrade from versions older than 4.06 could be unsuccessful. PBX has been left in the service mode.
• Fixed - new IL modules (with support of higher voltage for CLIP) haven’t displayed correctly in menu Global data/Hardware
• Info: Change in the firmware upload procedure – first are loaded language packals and after that the rest of data.
4.05 Y
• Fixed - new IL modules (with support of higher voltage for CLIP) haven’t displayed correctly in menu Global data/Hardware
4.07 D
• Auto CLIP routing – settings – separate menu
• The Italian menu on key (system) phones selection supported
• New Configuration Tool manual – version 1.6
4.06 S (service puprposes)
• Fixed problem in remote management over dialup modems – If the call from remote management modem has been manually transferred to the internal modem in Omega, the connection could be cancelled from the calling party side.
• Fixed problem – The Short Dial data from versions 4.05 and earlier couldn’t be exported to version 4.06.
2N® Omega Lite / 2N® Omega 48 – Configuration Tool
Release Notes
05.05.2010
4.08 C
• Support of new functions in firmware 4.08, till revision 5
• Fixed – Message „List index out of bounds“ appeared when going out of the ISDN line settings menu (sometimes, after upgrade from older firmware versions)
• The new Configuration Tool manual ver. 1.7
4.06 V, 4.07 H
• Fixed – Message „List index out of bounds“ appeared when going out of the ISDN line settings menu (sometimes, after upgrade from older firmware versions)
4.06 U, 4.07G
• !!! Fixed important error !!! – Upgrade from versions older than 4.06 could be unsuccessful. PBX has been left in the service mode.
• Fixed - new IL modules (with support of higher voltage for CLIP) haven’t displayed correctly in menu Global data/Hardware
• Info: Change in the firmware upload procedure – first are loaded language packals and after that the rest of data.
4.05 Y
• Fixed - new IL modules (with support of higher voltage for CLIP) haven’t displayed correctly in menu Global data/Hardware
4.07 D
• Auto CLIP routing – settings – separate menu
• The Italian menu on key (system) phones selection supported
• New Configuration Tool manual – version 1.6
4.06 S (service puprposes)
• Fixed problem in remote management over dialup modems – If the call from remote management modem has been manually transferred to the internal modem in Omega, the connection could be cancelled from the calling party side.
• Fixed problem – The Short Dial data from versions 4.05 and earlier couldn’t be exported to version 4.06.
Release Notes
05.05.2010
4.08 C
• Support of new functions in firmware 4.08, till revision 5
• Fixed – Message „List index out of bounds“ appeared when going out of the ISDN line settings menu (sometimes, after upgrade from older firmware versions)
• The new Configuration Tool manual ver. 1.7
4.06 V, 4.07 H
• Fixed – Message „List index out of bounds“ appeared when going out of the ISDN line settings menu (sometimes, after upgrade from older firmware versions)
4.06 U, 4.07G
• !!! Fixed important error !!! – Upgrade from versions older than 4.06 could be unsuccessful. PBX has been left in the service mode.
• Fixed - new IL modules (with support of higher voltage for CLIP) haven’t displayed correctly in menu Global data/Hardware
• Info: Change in the firmware upload procedure – first are loaded language packals and after that the rest of data.
4.05 Y
• Fixed - new IL modules (with support of higher voltage for CLIP) haven’t displayed correctly in menu Global data/Hardware
4.07 D
• Auto CLIP routing – settings – separate menu
• The Italian menu on key (system) phones selection supported
• New Configuration Tool manual – version 1.6
4.06 S (service puprposes)
• Fixed problem in remote management over dialup modems – If the call from remote management modem has been manually transferred to the internal modem in Omega, the connection could be cancelled from the calling party side.
• Fixed problem – The Short Dial data from versions 4.05 and earlier couldn’t be exported to version 4.06.
2N® Omega Lite / 2N® Omega 48 – Configuration Tool
Release Notes
05.05.2010
4.08 C
• Support of new functions in firmware 4.08, till revision 5
• Fixed – Message „List index out of bounds“ appeared when going out of the ISDN line settings menu (sometimes, after upgrade from older firmware versions)
• The new Configuration Tool manual ver. 1.7
4.06 V, 4.07 H
• Fixed – Message „List index out of bounds“ appeared when going out of the ISDN line settings menu (sometimes, after upgrade from older firmware versions)
4.06 U, 4.07G
• !!! Fixed important error !!! – Upgrade from versions older than 4.06 could be unsuccessful. PBX has been left in the service mode.
• Fixed - new IL modules (with support of higher voltage for CLIP) haven’t displayed correctly in menu Global data/Hardware
• Info: Change in the firmware upload procedure – first are loaded language packals and after that the rest of data.
4.05 Y
• Fixed - new IL modules (with support of higher voltage for CLIP) haven’t displayed correctly in menu Global data/Hardware
4.07 D
• Auto CLIP routing – settings – separate menu
• The Italian menu on key (system) phones selection supported
• New Configuration Tool manual – version 1.6
4.06 S (service puprposes)
• Fixed problem in remote management over dialup modems – If the call from remote management modem has been manually transferred to the internal modem in Omega, the connection could be cancelled from the calling party side.
• Fixed problem – The Short Dial data from versions 4.05 and earlier couldn’t be exported to version 4.06.
Release Notes
05.05.2010
4.08 C
• Support of new functions in firmware 4.08, till revision 5
• Fixed – Message „List index out of bounds“ appeared when going out of the ISDN line settings menu (sometimes, after upgrade from older firmware versions)
• The new Configuration Tool manual ver. 1.7
4.06 V, 4.07 H
• Fixed – Message „List index out of bounds“ appeared when going out of the ISDN line settings menu (sometimes, after upgrade from older firmware versions)
4.06 U, 4.07G
• !!! Fixed important error !!! – Upgrade from versions older than 4.06 could be unsuccessful. PBX has been left in the service mode.
• Fixed - new IL modules (with support of higher voltage for CLIP) haven’t displayed correctly in menu Global data/Hardware
• Info: Change in the firmware upload procedure – first are loaded language packals and after that the rest of data.
4.05 Y
• Fixed - new IL modules (with support of higher voltage for CLIP) haven’t displayed correctly in menu Global data/Hardware
4.07 D
• Auto CLIP routing – settings – separate menu
• The Italian menu on key (system) phones selection supported
• New Configuration Tool manual – version 1.6
4.06 S (service puprposes)
• Fixed problem in remote management over dialup modems – If the call from remote management modem has been manually transferred to the internal modem in Omega, the connection could be cancelled from the calling party side.
• Fixed problem – The Short Dial data from versions 4.05 and earlier couldn’t be exported to version 4.06.
2N® Omega Lite / 2N® Omega 48 – Configuration Tool
Release Notes
05.05.2010
4.08 C
• Support of new functions in firmware 4.08, till revision 5
• Fixed – Message „List index out of bounds“ appeared when going out of the ISDN line settings menu (sometimes, after upgrade from older firmware versions)
• The new Configuration Tool manual ver. 1.7
4.06 V, 4.07 H
• Fixed – Message „List index out of bounds“ appeared when going out of the ISDN line settings menu (sometimes, after upgrade from older firmware versions)
4.06 U, 4.07G
• !!! Fixed important error !!! – Upgrade from versions older than 4.06 could be unsuccessful. PBX has been left in the service mode.
• Fixed - new IL modules (with support of higher voltage for CLIP) haven’t displayed correctly in menu Global data/Hardware
• Info: Change in the firmware upload procedure – first are loaded language packals and after that the rest of data.
4.05 Y
• Fixed - new IL modules (with support of higher voltage for CLIP) haven’t displayed correctly in menu Global data/Hardware
4.07 D
• Auto CLIP routing – settings – separate menu
• The Italian menu on key (system) phones selection supported
• New Configuration Tool manual – version 1.6
4.06 S (service puprposes)
• Fixed problem in remote management over dialup modems – If the call from remote management modem has been manually transferred to the internal modem in Omega, the connection could be cancelled from the calling party side.
• Fixed problem – The Short Dial data from versions 4.05 and earlier couldn’t be exported to version 4.06.
Release Notes
05.05.2010
4.08 C
• Support of new functions in firmware 4.08, till revision 5
• Fixed – Message „List index out of bounds“ appeared when going out of the ISDN line settings menu (sometimes, after upgrade from older firmware versions)
• The new Configuration Tool manual ver. 1.7
4.06 V, 4.07 H
• Fixed – Message „List index out of bounds“ appeared when going out of the ISDN line settings menu (sometimes, after upgrade from older firmware versions)
4.06 U, 4.07G
• !!! Fixed important error !!! – Upgrade from versions older than 4.06 could be unsuccessful. PBX has been left in the service mode.
• Fixed - new IL modules (with support of higher voltage for CLIP) haven’t displayed correctly in menu Global data/Hardware
• Info: Change in the firmware upload procedure – first are loaded language packals and after that the rest of data.
4.05 Y
• Fixed - new IL modules (with support of higher voltage for CLIP) haven’t displayed correctly in menu Global data/Hardware
4.07 D
• Auto CLIP routing – settings – separate menu
• The Italian menu on key (system) phones selection supported
• New Configuration Tool manual – version 1.6
4.06 S (service puprposes)
• Fixed problem in remote management over dialup modems – If the call from remote management modem has been manually transferred to the internal modem in Omega, the connection could be cancelled from the calling party side.
• Fixed problem – The Short Dial data from versions 4.05 and earlier couldn’t be exported to version 4.06.
2N® Omega Lite / 2N® Omega 48 – Configuration Tool
Release Notes
09.04.2010
4.06 U, 4.07G
• !!! Fixed important error !!! – Upgrade from versions older than 4.06 could be unsuccessful. PBX has been left in the service mode.
• Fixed - new IL modules (with support of higher voltage for CLIP) haven’t displayed correctly in menu Global data/Hardware
• Info: Change in the firmware upload procedure – first are loaded language packals and after that the rest of data.
4.05 Y
• Fixed - new IL modules (with support of higher voltage for CLIP) haven’t displayed correctly in menu Global data/Hardware
4.07 D
• Auto CLIP routing – settings – separate menu
• The Italian menu on key (system) phones selection supported
• New Configuration Tool manual – version 1.6
4.06 S (service puprposes)
• Fixed problem in remote management over dialup modems – If the call from remote management modem has been manually transferred to the internal modem in Omega, the connection could be cancelled from the calling party side.
• Fixed problem – The Short Dial data from versions 4.05 and earlier couldn’t be exported to version 4.06.
Release Notes
09.04.2010
4.06 U, 4.07G
• !!! Fixed important error !!! – Upgrade from versions older than 4.06 could be unsuccessful. PBX has been left in the service mode.
• Fixed - new IL modules (with support of higher voltage for CLIP) haven’t displayed correctly in menu Global data/Hardware
• Info: Change in the firmware upload procedure – first are loaded language packals and after that the rest of data.
4.05 Y
• Fixed - new IL modules (with support of higher voltage for CLIP) haven’t displayed correctly in menu Global data/Hardware
4.07 D
• Auto CLIP routing – settings – separate menu
• The Italian menu on key (system) phones selection supported
• New Configuration Tool manual – version 1.6
4.06 S (service puprposes)
• Fixed problem in remote management over dialup modems – If the call from remote management modem has been manually transferred to the internal modem in Omega, the connection could be cancelled from the calling party side.
• Fixed problem – The Short Dial data from versions 4.05 and earlier couldn’t be exported to version 4.06.
2N® Omega Lite / 2N® Omega 48 – Configuration Tool
Release Notes
09.04.2010
4.06 U, 4.07G
• !!! Fixed important error !!! – Upgrade from versions older than 4.06 could be unsuccessful. PBX has been left in the service mode.
• Fixed - new IL modules (with support of higher voltage for CLIP) haven’t displayed correctly in menu Global data/Hardware
• Info: Change in the firmware upload procedure – first are loaded language packals and after that the rest of data.
4.05 Y
• Fixed - new IL modules (with support of higher voltage for CLIP) haven’t displayed correctly in menu Global data/Hardware
4.07 D
• Auto CLIP routing – settings – separate menu
• The Italian menu on key (system) phones selection supported
• New Configuration Tool manual – version 1.6
4.06 S (service puprposes)
• Fixed problem in remote management over dialup modems – If the call from remote management modem has been manually transferred to the internal modem in Omega, the connection could be cancelled from the calling party side.
• Fixed problem – The Short Dial data from versions 4.05 and earlier couldn’t be exported to version 4.06.
Release Notes
09.04.2010
4.06 U, 4.07G
• !!! Fixed important error !!! – Upgrade from versions older than 4.06 could be unsuccessful. PBX has been left in the service mode.
• Fixed - new IL modules (with support of higher voltage for CLIP) haven’t displayed correctly in menu Global data/Hardware
• Info: Change in the firmware upload procedure – first are loaded language packals and after that the rest of data.
4.05 Y
• Fixed - new IL modules (with support of higher voltage for CLIP) haven’t displayed correctly in menu Global data/Hardware
4.07 D
• Auto CLIP routing – settings – separate menu
• The Italian menu on key (system) phones selection supported
• New Configuration Tool manual – version 1.6
4.06 S (service puprposes)
• Fixed problem in remote management over dialup modems – If the call from remote management modem has been manually transferred to the internal modem in Omega, the connection could be cancelled from the calling party side.
• Fixed problem – The Short Dial data from versions 4.05 and earlier couldn’t be exported to version 4.06.
2N® Omega Lite / 2N® Omega 48 – Configuration Tool
Release Notes
09.04.2010
4.05 Y
• Fixed - new IL modules (with support of higher voltage for CLIP) haven’t displayed correctly in menu Global data/Hardware
Release Notes
09.04.2010
4.05 Y
• Fixed - new IL modules (with support of higher voltage for CLIP) haven’t displayed correctly in menu Global data/Hardware
2N® Omega Lite / 2N® Omega 48 – Configuration Tool
Release Notes
14.02.2010
4.07 D
• Auto CLIP routing – settings – separate menu
• The Italian menu on key (system) phones selection supported
• New Configuration Tool manual – version 1.6
4.06 S (service puprposes)
• Fixed problem in remote management over dialup modems – If the call from remote management modem has been manually transferred to the internal modem in Omega, the connection could be cancelled from the calling party side.
• Fixed problem – The Short Dial data from versions 4.05 and earlier couldn’t be exported to version 4.06.
Release Notes
14.02.2010
4.07 D
• Auto CLIP routing – settings – separate menu
• The Italian menu on key (system) phones selection supported
• New Configuration Tool manual – version 1.6
4.06 S (service puprposes)
• Fixed problem in remote management over dialup modems – If the call from remote management modem has been manually transferred to the internal modem in Omega, the connection could be cancelled from the calling party side.
• Fixed problem – The Short Dial data from versions 4.05 and earlier couldn’t be exported to version 4.06.
2N® Omega Lite/ 2N® Omega 48 – Firmware
Release Notes EN
01.02.2011
!!! WARNING !!! READ IT FIRST !!!
Upgrade from the firmware version 4.05 or earlier to the firmware version 4.06 or higher has to be done from the configuration tool corresponding to the target firmware version i.e 4.06, 4.07 etc. When you try to upgrade it from one of older versions, it causes destruction of data in the PBX. Then, firmware has to be uploaded from the boot (service) mode. You can get to the service mode using the lower button on the left side of the PBX. For details see the manual.
!!! The correct upgrade procedure:
- TAKE OUT THE ETHERNET MODULE (IF ANY), PUT BACK TWO JUMPERS AT THE ORIGINAL POSITION AND DO THE NEXT STEPS USING THE SERIAL PORT ON THE MOTHERBOARD
- make a backup of your configuration in your original config tool e.g. 4.05
- install the newest version of the config tool (4.06, 4.07, 4.08)
- do the upgrade of the firmware from the installed config tool (4.06, 4.07, 4.08)
- download config from the PBX in new config tool
- open your stored configuration in the originál config tool and rewrite it manualy to the new config tool
- upload configuration from the new config tool to PBX
4.10rev6
• !!! Fixed the bug in previous revisions - key phones stayed in the blocked status, PBX reset has been needed !!! The key phone module firmware upgrade to version 2.80 needed !!!
• Settings of 2N OpenStage key phone and PBX are paired
4.08rev10
• Searching in phone directory on system (key) phones using up to 3 leading characters. After that, it is possible to scroll the whole directory using < and > buttons.
• !!! Fixed the bug in previous revisions - If the call has come from UMTS or VoIP without the calling party identification, it has been proceeded according to the last call in the Auto CLIP Routing table. Now it is proceeded according to the relevant ringing table.
4.08rev8
• !!! Fixed the bug in previous revisions - Called numbes have been incorrectly presented in the list of called numbers on the key phone (some of them missed last digits and the last number had an additional 0 at the end). This bug could cause incorrect behaviour of AutoCLIP Routing.
4.08rev7
• !!! Fixed the bug in 4.08rev5 - If the cumulative length of all Text fields (name of the Short dial) is longer than 20 characters, following records couldn’t be saved correctly. This bug influented correct behaviour of the Event report SMSs too. If you have such configuration of the Short dials table, use this revision (or later) if doing upgrade to version 4.08! Use the configuration tool version 4.08D!
• !!! WARNING !!! Save the PBX configuration before upgrade to FW 4.08rev7. This upgrade automatically does the factory reset!!!
4.08rev5
• SMS Event reporting - info about: settings ganges, link failure, the SIM card credit, switch status etc.)
• Binary switch actions - send user SMS, block phones, block external lines, day/night switching, close contact relay).
• CLIR function - select if call would be made with identification or not. Could be associated to the key on the key phone. LED diode next to the key shines if CLIR is aktive.
• Fixed: DTMF sometimes not sent correctly from key phone to ISDN line
• Auto CLIP Routing enable/disable for each internal line separatelly (Internal lines/Enabling of services)
4.07rev9
• Fixed: Incorrect routing of incoming calls from CO line - AutoCLIP Routing service has been erroneously activated even in case when call has come over the CO line without CLIP identification.
4.07rev8
• Fixed – It hasn’t be able to make a short dial from the system (key) phone using service 80xx (fw version 4.07rev6)
• Fixed error in the GSM module trace – occasionally it could be found a fake alarm message in GSM trace „Some SMSs could be lost“ even when everything was OK (fw version 4.07rev6)
4.07rev6
• Auto CLIP routing feature.
• Italian menu on key (system) phones
4.06rev25
• !!! Fixed the risk of blocking system (key) phones – in the previous versions the next call to the busy system phone could sometimes cause blocking (workaround was to disable Internal lines/Enabling of services/Whole/Action/Next call ringing) !!!
4.06rev24
• Turkish menu on key (system) phones
• Tracing of the communication to key (system) phones – needed FW 2.70, at the system phone module
• Long distance prefix activated - Example: The long distance prefix is set. e.g. „0“. New call comes from the local country. If CLIP contains the international prefix of the country, that prefix is removed (must be set in the Configuration Tool too) and replaced with the long distance prefix. The modified CLIP is sent to the phone display and could be used for call back.
4.06rev18
• Hungarian language pack.
• Support of the older GSM modul FW versions 1.01 – 2.02. Older revisions of firmware 4.06 didn’t support those versions
4.06rev15
• Change in the forwarding to external lines – If the message „call is forwarded“ isn’t enabled, an incoming call to an extension, which is forwarded to a PSTN number, will not be picked up before it would be picked up at that PSTN number. In the previous versions, message has always been enabled and billing started even before the last destination has picked that call.
• Added option in ISDN line settings: „Don’t send request for AOC“ – blocks sending of facility Invoke AOC in the ISDN setup message. The ISDN modul firmware version ISM 16.01 is needed. Configuration tool version 4.06L or higher is needed.
4.06rev13
• Fixed critical error - blocking of key phones (caused by dat.acc and dat.dia file download)
• Fixed - In the case of ringing of a few extensions, if one picked up others had missed call
• Fixed - ME enable/disable couldn't be done from the ME mobile phone
Release Notes EN
01.02.2011
!!! WARNING !!! READ IT FIRST !!!
Upgrade from the firmware version 4.05 or earlier to the firmware version 4.06 or higher has to be done from the configuration tool corresponding to the target firmware version i.e 4.06, 4.07 etc. When you try to upgrade it from one of older versions, it causes destruction of data in the PBX. Then, firmware has to be uploaded from the boot (service) mode. You can get to the service mode using the lower button on the left side of the PBX. For details see the manual.
!!! The correct upgrade procedure:
- TAKE OUT THE ETHERNET MODULE (IF ANY), PUT BACK TWO JUMPERS AT THE ORIGINAL POSITION AND DO THE NEXT STEPS USING THE SERIAL PORT ON THE MOTHERBOARD
- make a backup of your configuration in your original config tool e.g. 4.05
- install the newest version of the config tool (4.06, 4.07, 4.08)
- do the upgrade of the firmware from the installed config tool (4.06, 4.07, 4.08)
- download config from the PBX in new config tool
- open your stored configuration in the originál config tool and rewrite it manualy to the new config tool
- upload configuration from the new config tool to PBX
4.10rev6
• !!! Fixed the bug in previous revisions - key phones stayed in the blocked status, PBX reset has been needed !!! The key phone module firmware upgrade to version 2.80 needed !!!
• Settings of 2N OpenStage key phone and PBX are paired
4.08rev10
• Searching in phone directory on system (key) phones using up to 3 leading characters. After that, it is possible to scroll the whole directory using < and > buttons.
• !!! Fixed the bug in previous revisions - If the call has come from UMTS or VoIP without the calling party identification, it has been proceeded according to the last call in the Auto CLIP Routing table. Now it is proceeded according to the relevant ringing table.
4.08rev8
• !!! Fixed the bug in previous revisions - Called numbes have been incorrectly presented in the list of called numbers on the key phone (some of them missed last digits and the last number had an additional 0 at the end). This bug could cause incorrect behaviour of AutoCLIP Routing.
4.08rev7
• !!! Fixed the bug in 4.08rev5 - If the cumulative length of all Text fields (name of the Short dial) is longer than 20 characters, following records couldn’t be saved correctly. This bug influented correct behaviour of the Event report SMSs too. If you have such configuration of the Short dials table, use this revision (or later) if doing upgrade to version 4.08! Use the configuration tool version 4.08D!
• !!! WARNING !!! Save the PBX configuration before upgrade to FW 4.08rev7. This upgrade automatically does the factory reset!!!
4.08rev5
• SMS Event reporting - info about: settings ganges, link failure, the SIM card credit, switch status etc.)
• Binary switch actions - send user SMS, block phones, block external lines, day/night switching, close contact relay).
• CLIR function - select if call would be made with identification or not. Could be associated to the key on the key phone. LED diode next to the key shines if CLIR is aktive.
• Fixed: DTMF sometimes not sent correctly from key phone to ISDN line
• Auto CLIP Routing enable/disable for each internal line separatelly (Internal lines/Enabling of services)
4.07rev9
• Fixed: Incorrect routing of incoming calls from CO line - AutoCLIP Routing service has been erroneously activated even in case when call has come over the CO line without CLIP identification.
4.07rev8
• Fixed – It hasn’t be able to make a short dial from the system (key) phone using service 80xx (fw version 4.07rev6)
• Fixed error in the GSM module trace – occasionally it could be found a fake alarm message in GSM trace „Some SMSs could be lost“ even when everything was OK (fw version 4.07rev6)
4.07rev6
• Auto CLIP routing feature.
• Italian menu on key (system) phones
4.06rev25
• !!! Fixed the risk of blocking system (key) phones – in the previous versions the next call to the busy system phone could sometimes cause blocking (workaround was to disable Internal lines/Enabling of services/Whole/Action/Next call ringing) !!!
4.06rev24
• Turkish menu on key (system) phones
• Tracing of the communication to key (system) phones – needed FW 2.70, at the system phone module
• Long distance prefix activated - Example: The long distance prefix is set. e.g. „0“. New call comes from the local country. If CLIP contains the international prefix of the country, that prefix is removed (must be set in the Configuration Tool too) and replaced with the long distance prefix. The modified CLIP is sent to the phone display and could be used for call back.
4.06rev18
• Hungarian language pack.
• Support of the older GSM modul FW versions 1.01 – 2.02. Older revisions of firmware 4.06 didn’t support those versions
4.06rev15
• Change in the forwarding to external lines – If the message „call is forwarded“ isn’t enabled, an incoming call to an extension, which is forwarded to a PSTN number, will not be picked up before it would be picked up at that PSTN number. In the previous versions, message has always been enabled and billing started even before the last destination has picked that call.
• Added option in ISDN line settings: „Don’t send request for AOC“ – blocks sending of facility Invoke AOC in the ISDN setup message. The ISDN modul firmware version ISM 16.01 is needed. Configuration tool version 4.06L or higher is needed.
4.06rev13
• Fixed critical error - blocking of key phones (caused by dat.acc and dat.dia file download)
• Fixed - In the case of ringing of a few extensions, if one picked up others had missed call
• Fixed - ME enable/disable couldn't be done from the ME mobile phone
2N® Omega Lite/ 2N® Omega 48 – Firmware
Release Notes EN
01.02.2011
!!! WARNING !!! READ IT FIRST !!!
Upgrade from the firmware version 4.05 or earlier to the firmware version 4.06 or higher has to be done from the configuration tool corresponding to the target firmware version i.e 4.06, 4.07 etc. When you try to upgrade it from one of older versions, it causes destruction of data in the PBX. Then, firmware has to be uploaded from the boot (service) mode. You can get to the service mode using the lower button on the left side of the PBX. For details see the manual.
!!! The correct upgrade procedure:
- TAKE OUT THE ETHERNET MODULE (IF ANY), PUT BACK TWO JUMPERS AT THE ORIGINAL POSITION AND DO THE NEXT STEPS USING THE SERIAL PORT ON THE MOTHERBOARD
- make a backup of your configuration in your original config tool e.g. 4.05
- install the newest version of the config tool (4.06, 4.07, 4.08)
- do the upgrade of the firmware from the installed config tool (4.06, 4.07, 4.08)
- download config from the PBX in new config tool
- open your stored configuration in the originál config tool and rewrite it manualy to the new config tool
- upload configuration from the new config tool to PBX
4.10rev6
• !!! Fixed the bug in previous revisions - key phones stayed in the blocked status, PBX reset has been needed !!! The key phone module firmware upgrade to version 2.80 needed !!!
• Settings of 2N OpenStage key phone and PBX are paired
4.10rev6
• !!! Fixed the bug in previous revisions - key phones stayed in the blocked status, PBX reset has been needed !!! The key phone module firmware upgrade to version 2.80 needed !!!
• Settings of 2N OpenStage key phone and PBX are paired
4.08rev10
• Searching in phone directory on system (key) phones using up to 3 leading characters. After that, it is possible to scroll the whole directory using < and > buttons.
• !!! Fixed the bug in previous revisions - If the call has come from UMTS or VoIP without the calling party identification, it has been proceeded according to the last call in the Auto CLIP Routing table. Now it is proceeded according to the relevant ringing table.
4.08rev8
• !!! Fixed the bug in previous revisions - Called numbes have been incorrectly presented in the list of called numbers on the key phone (some of them missed last digits and the last number had an additional 0 at the end). This bug could cause incorrect behaviour of AutoCLIP Routing.
4.08rev7
• !!! Fixed the bug in 4.08rev5 - If the cumulative length of all Text fields (name of the Short dial) is longer than 20 characters, following records couldn’t be saved correctly. This bug influented correct behaviour of the Event report SMSs too. If you have such configuration of the Short dials table, use this revision (or later) if doing upgrade to version 4.08! Use the configuration tool version 4.08D!
• !!! WARNING !!! Save the PBX configuration before upgrade to FW 4.08rev7. This upgrade automatically does the factory reset!!!
4.08rev5
• SMS Event reporting - info about: settings ganges, link failure, the SIM card credit, switch status etc.)
• Binary switch actions - send user SMS, block phones, block external lines, day/night switching, close contact relay).
• CLIR function - select if call would be made with identification or not. Could be associated to the key on the key phone. LED diode next to the key shines if CLIR is aktive.
• Fixed: DTMF sometimes not sent correctly from key phone to ISDN line
• Auto CLIP Routing enable/disable for each internal line separatelly (Internal lines/Enabling of services)
4.07rev9
• Fixed: Incorrect routing of incoming calls from CO line - AutoCLIP Routing service has been erroneously activated even in case when call has come over the CO line without CLIP identification.
4.07rev8
• Fixed – It hasn’t be able to make a short dial from the system (key) phone using service 80xx (fw version 4.07rev6)
• Fixed error in the GSM module trace – occasionally it could be found a fake alarm message in GSM trace „Some SMSs could be lost“ even when everything was OK (fw version 4.07rev6)
4.07rev6
• Auto CLIP routing feature.
• Italian menu on key (system) phones
4.06rev25
• !!! Fixed the risk of blocking system (key) phones – in the previous versions the next call to the busy system phone could sometimes cause blocking (workaround was to disable Internal lines/Enabling of services/Whole/Action/Next call ringing) !!!
4.06rev24
• Turkish menu on key (system) phones
• Tracing of the communication to key (system) phones – needed FW 2.70, at the system phone module
• Long distance prefix activated - Example: The long distance prefix is set. e.g. „0“. New call comes from the local country. If CLIP contains the international prefix of the country, that prefix is removed (must be set in the Configuration Tool too) and replaced with the long distance prefix. The modified CLIP is sent to the phone display and could be used for call back.
4.06rev18
• Hungarian language pack.
• Support of the older GSM modul FW versions 1.01 – 2.02. Older revisions of firmware 4.06 didn’t support those versions
4.06rev15
• Change in the forwarding to external lines – If the message „call is forwarded“ isn’t enabled, an incoming call to an extension, which is forwarded to a PSTN number, will not be picked up before it would be picked up at that PSTN number. In the previous versions, message has always been enabled and billing started even before the last destination has picked that call.
• Added option in ISDN line settings: „Don’t send request for AOC“ – blocks sending of facility Invoke AOC in the ISDN setup message. The ISDN modul firmware version ISM 16.01 is needed. Configuration tool version 4.06L or higher is needed.
4.06rev13
• Fixed critical error - blocking of key phones (caused by dat.acc and dat.dia file download)
• Fixed - In the case of ringing of a few extensions, if one picked up others had missed call
• Fixed - ME enable/disable couldn't be done from the ME mobile phone
Release Notes EN
01.02.2011
!!! WARNING !!! READ IT FIRST !!!
Upgrade from the firmware version 4.05 or earlier to the firmware version 4.06 or higher has to be done from the configuration tool corresponding to the target firmware version i.e 4.06, 4.07 etc. When you try to upgrade it from one of older versions, it causes destruction of data in the PBX. Then, firmware has to be uploaded from the boot (service) mode. You can get to the service mode using the lower button on the left side of the PBX. For details see the manual.
!!! The correct upgrade procedure:
- TAKE OUT THE ETHERNET MODULE (IF ANY), PUT BACK TWO JUMPERS AT THE ORIGINAL POSITION AND DO THE NEXT STEPS USING THE SERIAL PORT ON THE MOTHERBOARD
- make a backup of your configuration in your original config tool e.g. 4.05
- install the newest version of the config tool (4.06, 4.07, 4.08)
- do the upgrade of the firmware from the installed config tool (4.06, 4.07, 4.08)
- download config from the PBX in new config tool
- open your stored configuration in the originál config tool and rewrite it manualy to the new config tool
- upload configuration from the new config tool to PBX
4.10rev6
• !!! Fixed the bug in previous revisions - key phones stayed in the blocked status, PBX reset has been needed !!! The key phone module firmware upgrade to version 2.80 needed !!!
• Settings of 2N OpenStage key phone and PBX are paired
4.10rev6
• !!! Fixed the bug in previous revisions - key phones stayed in the blocked status, PBX reset has been needed !!! The key phone module firmware upgrade to version 2.80 needed !!!
• Settings of 2N OpenStage key phone and PBX are paired
4.08rev10
• Searching in phone directory on system (key) phones using up to 3 leading characters. After that, it is possible to scroll the whole directory using < and > buttons.
• !!! Fixed the bug in previous revisions - If the call has come from UMTS or VoIP without the calling party identification, it has been proceeded according to the last call in the Auto CLIP Routing table. Now it is proceeded according to the relevant ringing table.
4.08rev8
• !!! Fixed the bug in previous revisions - Called numbes have been incorrectly presented in the list of called numbers on the key phone (some of them missed last digits and the last number had an additional 0 at the end). This bug could cause incorrect behaviour of AutoCLIP Routing.
4.08rev7
• !!! Fixed the bug in 4.08rev5 - If the cumulative length of all Text fields (name of the Short dial) is longer than 20 characters, following records couldn’t be saved correctly. This bug influented correct behaviour of the Event report SMSs too. If you have such configuration of the Short dials table, use this revision (or later) if doing upgrade to version 4.08! Use the configuration tool version 4.08D!
• !!! WARNING !!! Save the PBX configuration before upgrade to FW 4.08rev7. This upgrade automatically does the factory reset!!!
4.08rev5
• SMS Event reporting - info about: settings ganges, link failure, the SIM card credit, switch status etc.)
• Binary switch actions - send user SMS, block phones, block external lines, day/night switching, close contact relay).
• CLIR function - select if call would be made with identification or not. Could be associated to the key on the key phone. LED diode next to the key shines if CLIR is aktive.
• Fixed: DTMF sometimes not sent correctly from key phone to ISDN line
• Auto CLIP Routing enable/disable for each internal line separatelly (Internal lines/Enabling of services)
4.07rev9
• Fixed: Incorrect routing of incoming calls from CO line - AutoCLIP Routing service has been erroneously activated even in case when call has come over the CO line without CLIP identification.
4.07rev8
• Fixed – It hasn’t be able to make a short dial from the system (key) phone using service 80xx (fw version 4.07rev6)
• Fixed error in the GSM module trace – occasionally it could be found a fake alarm message in GSM trace „Some SMSs could be lost“ even when everything was OK (fw version 4.07rev6)
4.07rev6
• Auto CLIP routing feature.
• Italian menu on key (system) phones
4.06rev25
• !!! Fixed the risk of blocking system (key) phones – in the previous versions the next call to the busy system phone could sometimes cause blocking (workaround was to disable Internal lines/Enabling of services/Whole/Action/Next call ringing) !!!
4.06rev24
• Turkish menu on key (system) phones
• Tracing of the communication to key (system) phones – needed FW 2.70, at the system phone module
• Long distance prefix activated - Example: The long distance prefix is set. e.g. „0“. New call comes from the local country. If CLIP contains the international prefix of the country, that prefix is removed (must be set in the Configuration Tool too) and replaced with the long distance prefix. The modified CLIP is sent to the phone display and could be used for call back.
4.06rev18
• Hungarian language pack.
• Support of the older GSM modul FW versions 1.01 – 2.02. Older revisions of firmware 4.06 didn’t support those versions
4.06rev15
• Change in the forwarding to external lines – If the message „call is forwarded“ isn’t enabled, an incoming call to an extension, which is forwarded to a PSTN number, will not be picked up before it would be picked up at that PSTN number. In the previous versions, message has always been enabled and billing started even before the last destination has picked that call.
• Added option in ISDN line settings: „Don’t send request for AOC“ – blocks sending of facility Invoke AOC in the ISDN setup message. The ISDN modul firmware version ISM 16.01 is needed. Configuration tool version 4.06L or higher is needed.
4.06rev13
• Fixed critical error - blocking of key phones (caused by dat.acc and dat.dia file download)
• Fixed - In the case of ringing of a few extensions, if one picked up others had missed call
• Fixed - ME enable/disable couldn't be done from the ME mobile phone
2N® Omega Lite / 2N® Omega 48 - Ethernet module firmware
Release Notes
12.11.2010
OLI-2-3-11 2010-11-12
• Fixed – in LCR normalisation, the Caller incoming setting has been switched to Called outgoing when the record has been opened for editing e.g. to change the prefix
• The Configuration restore - by default license in the device will not be rewritten by the licence from backup
• XAPI 2.02D – Fixed - XAPI tracing couldn’t be saved to the file in the XAPI Console
OLI-2-3-10 2010-09-20
• Fixed bug – DTMF digits which has been received from the H.323 line, haven’t been sent forward
• XAPI 2.02A (see Release Notes XAPI Server ver. 1.20A)
OLI-2-3-7 2010-05-19
• Mobility Extension on SIP extensions !!! Incoming ME on SIP extensions works only if the call comes from the basic part of Omega Lite/ Omega 48 i.e. from GSM, ISDN or CO lines !!!
• Music-on-hold
• Maximal DISA length enlarged to 500kB
• CLIR service (Calling Line Identification Restriction) when calling over SIP lines (header Privacy: id)
• PPPoE – connection to Internet over ADSL modem or router in bridged mode
• Sending USSD messages over the UMTS module
• XAPI 2.01S
OLI-2-3-6 2010-02-21
• This version is displayed in web configuration interface as 2.3.6a
• !!! Fixed the critical bug – Calling from VoIP to analogue or system phone extension, that has an active voicemail, calling party could listen messages left in the called party voice mailbox. (since firmware 2.3.2)
• Xapi 2.01N
OLI-2-3-5 2009-12-23
• Backup of configuration contains only configuration folders
• Web interface – the lower left angle icons are unified in various menus
• XAPI 2.01J – fixed problem of firmware upgrade from the configuration tool, over port 1234
• PPP – significantly improved uplink data rate over UMTS module
• Web interface - improved response time
• Ring Groups - VoIP phones (extensions) could be rang together
• new default password of Admin is 2n
• DNS – fixed problem of cyclical rebooting of Ethernet module – It happened if DNS proxy was enabled and DNS servers haven’t been set
• SIP - header Diversion
• Fixed the problem with Sierra module – if RING has come during SMS sending, SMS was treated as not sent
• Voicemail – warning about almost filled up message space
OLI-2-3-2 2009-11-04
• DISA message in Ethernet module – new settings – fall to the default operator, maximal duration of the voice mail message, improved voice quality of messages
• Listen port displayed in the SIP lines menu
• H.323 – the calling party identification in incomming calls- corrected
• QoS indication could be set for RTP and SIP
• XAPI 2.01H
OLI-2-3-1 2009-09-23
• integrated XAPI server
• new, more reliable H.323 stack
• DISA - interdigit timeout, limited call duration, cycling limit
• default IP address 192.168.1.1
2N® Omega Lite / 2N® Omega 48 - Ethernet module firmware
Release Notes
20.09.2010
OLI-2-3-10 2010-09-20
• Fixed bug – DTMF digits which has been received from the H.323 line, haven’t
been sent forward
• XAPI 2.02A (see Release Notes XAPI Server ver. 1.20A)
OLI-2-3-7 2010-05-19
• Mobility Extension on SIP extensions !!! Incoming ME on SIP extensions works
only if the call comes from the basic part of Omega Lite/ Omega 48 i.e. from GSM, ISDN
or CO lines !!!
• Music-on-hold
• Maximal DISA length enlarged to 500kB
• CLIR service (Calling Line Identification Restriction) when calling over SIP
lines (header Privacy: id)
• PPPoE – connection to Internet over ADSL modem or router in bridged mode
• Sending USSD messages over the UMTS module
• XAPI 2.01S
OLI-2-3-6 2010-02-21
• This version is displayed in web configuration interface as 2.3.6a
• !!! Fixed the critical bug – Calling from VoIP to analogue or system phone
extension, that has an active voicemail, calling party could listen messages left in
the called party voice mailbox. (since firmware 2.3.2)
• Xapi 2.01N
OLI-2-3-5 2009-12-23
• Backup of configuration contains only configuration folders
• Web interface – the lower left angle icons are unified in various menus
• XAPI 2.01J – fixed problem of firmware upgrade from the configuration tool,
over port 1234
• PPP – significantly improved uplink data rate over UMTS module
• Web interface - improved response time
• Ring Groups - VoIP phones (extensions) could be rang together
• new default password of Admin is 2n
• DNS – fixed problem of cyclical rebooting of Ethernet module – It happened if
DNS proxy was enabled and DNS servers haven’t been set
• SIP - header Diversion
• Fixed the problem with Sierra module – if RING has come during SMS sending, SMS
was treated as not sent
• Voicemail – warning about almost filled up message space
OLI-2-3-2 2009-11-04
• DISA message in Ethernet module – new settings – fall to the default operator,
maximal duration of the voice mail message, improved voice quality of messages
• Listen port displayed in the SIP lines menu
• H.323 – the calling party identification in incomming calls- corrected
• QoS indication could be set for RTP and SIP
• XAPI 2.01H
OLI-2-3-1 2009-09-23
• integrated XAPI server
• new, more reliable H.323 stack
• DISA - interdigit timeout, limited call duration, cycling limit
• default IP address 192.168.1.1
2N® Omega Lite/ 2N® Omega 48 – Firmware
Release Notes EN
26.07.2010
!!! WARNING !!!
Upgrade from the firmware version 4.05 or earlier to the firmware version 4.06 or higher has to be done from the configuration tool corresponding to the target firmware version i.e 4.06, 4.07 etc. When you try to upgrade it from one of older versions, it causes destruction of data in the PBX. Then, firmware has to be uploaded from the boot (service) mode. You can get to the service mode using the lower button on the left side of the PBX. For details see the manual.
!!! The correct upgrade procedure:
- make a backup of your configuration in your original config tool e.g. 4.05
- install the newest version of the config tool (4.06, 4.07, 4.08)
- do the upgrade of the firmware from the installed config tool (4.06, 4.07, 4.08)
- download config from the PBX in new config tool
- open your stored configuration in the originál config tool and rewrite it manualy to the new config tool
- upload configuration from the new config tool to PBX
4.08rev10
• Searching in phone directory on system (key) phones using up to 3 leading characters. After that, it is possible to scroll the whole directory using < and > buttons.
• !!! Fixed the bug in previous revisions - If the call has come from UMTS or VoIP without the calling party identification, it has been proceeded according to the last call in the Auto CLIP Routing table. Now it is proceeded according to the relevant ringing table.
4.08rev8
• !!! Fixed the bug in previous revisions - Called numbes have been incorrectly presented in the list of called numbers on the key phone (some of them missed last digits and the last number had an additional 0 at the end). This bug could cause incorrect behaviour of AutoCLIP Routing.
4.08rev7
• !!! Fixed the bug in 4.08rev5 - If the cumulative length of all Text fields (name of the Short dial) is longer than 20 characters, following records couldn’t be saved correctly. This bug influented correct behaviour of the Event report SMSs too. If you have such configuration of the Short dials table, use this revision (or later) if doing upgrade to version 4.08! Use the configuration tool version 4.08D!
• !!! WARNING !!! Save the PBX configuration before upgrade to FW 4.08rev7. This upgrade automatically does the factory reset!!!
4.08rev5
• SMS Event reporting - info about: settings ganges, link failure, the SIM card credit, switch status etc.)
• Binary switch actions - send user SMS, block phones, block external lines, day/night switching, close contact relay).
• CLIR function - select if call would be made with identification or not. Could be associated to the key on the key phone. LED diode next to the key shines if CLIR is aktive.
• Fixed: DTMF sometimes not sent correctly from key phone to ISDN line
• Auto CLIP Routing enable/disable for each internal line separatelly (Internal lines/Enabling of services)
4.07rev9
• Fixed: Incorrect routing of incoming calls from CO line - AutoCLIP Routing service has been erroneously activated even in case when call has come over the CO line without CLIP identification.
4.07rev8
• Fixed – It hasn’t be able to make a short dial from the system (key) phone using service 80xx (fw version 4.07rev6)
• Fixed error in the GSM module trace – occasionally it could be found a fake alarm message in GSM trace „Some SMSs could be lost“ even when everything was OK (fw version 4.07rev6)
4.07rev6
• Auto CLIP routing feature.
• Italian menu on key (system) phones
4.06rev25
• !!! Fixed the risk of blocking system (key) phones – in the previous versions the next call to the busy system phone could sometimes cause blocking (workaround was to disable Internal lines/Enabling of services/Whole/Action/Next call ringing) !!!
4.06rev24
• Turkish menu on key (system) phones
• Tracing of the communication to key (system) phones – needed FW 2.70, at the system phone module
• Long distance prefix activated - Example: The long distance prefix is set. e.g. „0“. New call comes from the local country. If CLIP contains the international prefix of the country, that prefix is removed (must be set in the Configuration Tool too) and replaced with the long distance prefix. The modified CLIP is sent to the phone display and could be used for call back.
4.06rev18
• Hungarian language pack.
• Support of the older GSM modul FW versions 1.01 – 2.02. Older revisions of firmware 4.06 didn’t support those versions
4.06rev15
• Change in the forwarding to external lines – If the message „call is forwarded“ isn’t enabled, an incoming call to an extension, which is forwarded to a PSTN number, will not be picked up before it would be picked up at that PSTN number. In the previous versions, message has always been enabled and billing started even before the last destination has picked that call.
• Added option in ISDN line settings: „Don’t send request for AOC“ – blocks sending of facility Invoke AOC in the ISDN setup message. The ISDN modul firmware version ISM 16.01 is needed. Configuration tool version 4.06L or higher is needed.
4.06rev13
• Fixed critical error - blocking of key phones (caused by dat.acc and dat.dia file download)
• Fixed - In the case of ringing of a few extensions, if one picked up others had missed call
• Fixed - ME enable/disable couldn't be done from the ME mobile phone
Release Notes EN
26.07.2010
!!! WARNING !!!
Upgrade from the firmware version 4.05 or earlier to the firmware version 4.06 or higher has to be done from the configuration tool corresponding to the target firmware version i.e 4.06, 4.07 etc. When you try to upgrade it from one of older versions, it causes destruction of data in the PBX. Then, firmware has to be uploaded from the boot (service) mode. You can get to the service mode using the lower button on the left side of the PBX. For details see the manual.
!!! The correct upgrade procedure:
- make a backup of your configuration in your original config tool e.g. 4.05
- install the newest version of the config tool (4.06, 4.07, 4.08)
- do the upgrade of the firmware from the installed config tool (4.06, 4.07, 4.08)
- download config from the PBX in new config tool
- open your stored configuration in the originál config tool and rewrite it manualy to the new config tool
- upload configuration from the new config tool to PBX
4.08rev10
• Searching in phone directory on system (key) phones using up to 3 leading characters. After that, it is possible to scroll the whole directory using < and > buttons.
• !!! Fixed the bug in previous revisions - If the call has come from UMTS or VoIP without the calling party identification, it has been proceeded according to the last call in the Auto CLIP Routing table. Now it is proceeded according to the relevant ringing table.
4.08rev8
• !!! Fixed the bug in previous revisions - Called numbes have been incorrectly presented in the list of called numbers on the key phone (some of them missed last digits and the last number had an additional 0 at the end). This bug could cause incorrect behaviour of AutoCLIP Routing.
4.08rev7
• !!! Fixed the bug in 4.08rev5 - If the cumulative length of all Text fields (name of the Short dial) is longer than 20 characters, following records couldn’t be saved correctly. This bug influented correct behaviour of the Event report SMSs too. If you have such configuration of the Short dials table, use this revision (or later) if doing upgrade to version 4.08! Use the configuration tool version 4.08D!
• !!! WARNING !!! Save the PBX configuration before upgrade to FW 4.08rev7. This upgrade automatically does the factory reset!!!
4.08rev5
• SMS Event reporting - info about: settings ganges, link failure, the SIM card credit, switch status etc.)
• Binary switch actions - send user SMS, block phones, block external lines, day/night switching, close contact relay).
• CLIR function - select if call would be made with identification or not. Could be associated to the key on the key phone. LED diode next to the key shines if CLIR is aktive.
• Fixed: DTMF sometimes not sent correctly from key phone to ISDN line
• Auto CLIP Routing enable/disable for each internal line separatelly (Internal lines/Enabling of services)
4.07rev9
• Fixed: Incorrect routing of incoming calls from CO line - AutoCLIP Routing service has been erroneously activated even in case when call has come over the CO line without CLIP identification.
4.07rev8
• Fixed – It hasn’t be able to make a short dial from the system (key) phone using service 80xx (fw version 4.07rev6)
• Fixed error in the GSM module trace – occasionally it could be found a fake alarm message in GSM trace „Some SMSs could be lost“ even when everything was OK (fw version 4.07rev6)
4.07rev6
• Auto CLIP routing feature.
• Italian menu on key (system) phones
4.06rev25
• !!! Fixed the risk of blocking system (key) phones – in the previous versions the next call to the busy system phone could sometimes cause blocking (workaround was to disable Internal lines/Enabling of services/Whole/Action/Next call ringing) !!!
4.06rev24
• Turkish menu on key (system) phones
• Tracing of the communication to key (system) phones – needed FW 2.70, at the system phone module
• Long distance prefix activated - Example: The long distance prefix is set. e.g. „0“. New call comes from the local country. If CLIP contains the international prefix of the country, that prefix is removed (must be set in the Configuration Tool too) and replaced with the long distance prefix. The modified CLIP is sent to the phone display and could be used for call back.
4.06rev18
• Hungarian language pack.
• Support of the older GSM modul FW versions 1.01 – 2.02. Older revisions of firmware 4.06 didn’t support those versions
4.06rev15
• Change in the forwarding to external lines – If the message „call is forwarded“ isn’t enabled, an incoming call to an extension, which is forwarded to a PSTN number, will not be picked up before it would be picked up at that PSTN number. In the previous versions, message has always been enabled and billing started even before the last destination has picked that call.
• Added option in ISDN line settings: „Don’t send request for AOC“ – blocks sending of facility Invoke AOC in the ISDN setup message. The ISDN modul firmware version ISM 16.01 is needed. Configuration tool version 4.06L or higher is needed.
4.06rev13
• Fixed critical error - blocking of key phones (caused by dat.acc and dat.dia file download)
• Fixed - In the case of ringing of a few extensions, if one picked up others had missed call
• Fixed - ME enable/disable couldn't be done from the ME mobile phone
2N® Omega Lite/ 2N® Omega 48 – Firmware
Release Notes EN
26.07.2010
!!! WARNING !!!
Upgrade from the firmware version 4.05 or earlier to the firmware version 4.06 or higher has to be done from the configuration tool corresponding to the target firmware version i.e 4.06, 4.07 etc. When you try to upgrade it from one of older versions, it causes destruction of data in the PBX. Then, firmware has to be uploaded from the boot (service) mode. You can get to the service mode using the lower button on the left side of the PBX. For details see the manual.
!!! The correct upgrade procedure:
- make a backup of your configuration in your original config tool e.g. 4.05
- install the newest version of the config tool (4.06, 4.07, 4.08)
- do the upgrade of the firmware from the installed config tool (4.06, 4.07, 4.08)
- download config from the PBX in new config tool
- open your stored configuration in the originál config tool and rewrite it manualy to the new config tool
- upload configuration from the new config tool to PBX
4.08rev10
• Searching in phone directory on system (key) phones using up to 3 leading characters. After that, it is possible to scroll the whole directory using < and > buttons.
• !!! Fixed the bug in previous revisions - If the call has come from UMTS or VoIP without the calling party identification, it has been proceeded according to the last call in the Auto CLIP Routing table. Now it is proceeded according to the relevant ringing table.
4.08rev8
• !!! Fixed the bug in previous revisions - Called numbes have been incorrectly presented in the list of called numbers on the key phone (some of them missed last digits and the last number had an additional 0 at the end). This bug could cause incorrect behaviour of AutoCLIP Routing.
4.08rev7
• !!! Fixed the bug in 4.08rev5 - If the cumulative length of all Text fields (name of the Short dial) is longer than 20 characters, following records couldn’t be saved correctly. This bug influented correct behaviour of the Event report SMSs too. If you have such configuration of the Short dials table, use this revision (or later) if doing upgrade to version 4.08! Use the configuration tool version 4.08D!
• !!! WARNING !!! Save the PBX configuration before upgrade to FW 4.08rev7. This upgrade automatically does the factory reset!!!
4.08rev5
• SMS Event reporting - info about: settings ganges, link failure, the SIM card credit, switch status etc.)
• Binary switch actions - send user SMS, block phones, block external lines, day/night switching, close contact relay).
• CLIR function - select if call would be made with identification or not. Could be associated to the key on the key phone. LED diode next to the key shines if CLIR is aktive.
• Fixed: DTMF sometimes not sent correctly from key phone to ISDN line
• Auto CLIP Routing enable/disable for each internal line separatelly (Internal lines/Enabling of services)
4.07rev9
• Fixed: Incorrect routing of incoming calls from CO line - AutoCLIP Routing service has been erroneously activated even in case when call has come over the CO line without CLIP identification.
4.07rev8
• Fixed – It hasn’t be able to make a short dial from the system (key) phone using service 80xx (fw version 4.07rev6)
• Fixed error in the GSM module trace – occasionally it could be found a fake alarm message in GSM trace „Some SMSs could be lost“ even when everything was OK (fw version 4.07rev6)
4.07rev6
• Auto CLIP routing feature.
• Italian menu on key (system) phones
4.06rev25
• !!! Fixed the risk of blocking system (key) phones – in the previous versions the next call to the busy system phone could sometimes cause blocking (workaround was to disable Internal lines/Enabling of services/Whole/Action/Next call ringing) !!!
4.06rev24
• Turkish menu on key (system) phones
• Tracing of the communication to key (system) phones – needed FW 2.70, at the system phone module
• Long distance prefix activated - Example: The long distance prefix is set. e.g. „0“. New call comes from the local country. If CLIP contains the international prefix of the country, that prefix is removed (must be set in the Configuration Tool too) and replaced with the long distance prefix. The modified CLIP is sent to the phone display and could be used for call back.
4.06rev18
• Hungarian language pack.
• Support of the older GSM modul FW versions 1.01 – 2.02. Older revisions of firmware 4.06 didn’t support those versions
4.06rev15
• Change in the forwarding to external lines – If the message „call is forwarded“ isn’t enabled, an incoming call to an extension, which is forwarded to a PSTN number, will not be picked up before it would be picked up at that PSTN number. In the previous versions, message has always been enabled and billing started even before the last destination has picked that call.
• Added option in ISDN line settings: „Don’t send request for AOC“ – blocks sending of facility Invoke AOC in the ISDN setup message. The ISDN modul firmware version ISM 16.01 is needed. Configuration tool version 4.06L or higher is needed.
4.06rev13
• Fixed critical error - blocking of key phones (caused by dat.acc and dat.dia file download)
• Fixed - In the case of ringing of a few extensions, if one picked up others had missed call
• Fixed - ME enable/disable couldn't be done from the ME mobile phone
Release Notes EN
26.07.2010
!!! WARNING !!!
Upgrade from the firmware version 4.05 or earlier to the firmware version 4.06 or higher has to be done from the configuration tool corresponding to the target firmware version i.e 4.06, 4.07 etc. When you try to upgrade it from one of older versions, it causes destruction of data in the PBX. Then, firmware has to be uploaded from the boot (service) mode. You can get to the service mode using the lower button on the left side of the PBX. For details see the manual.
!!! The correct upgrade procedure:
- make a backup of your configuration in your original config tool e.g. 4.05
- install the newest version of the config tool (4.06, 4.07, 4.08)
- do the upgrade of the firmware from the installed config tool (4.06, 4.07, 4.08)
- download config from the PBX in new config tool
- open your stored configuration in the originál config tool and rewrite it manualy to the new config tool
- upload configuration from the new config tool to PBX
4.08rev10
• Searching in phone directory on system (key) phones using up to 3 leading characters. After that, it is possible to scroll the whole directory using < and > buttons.
• !!! Fixed the bug in previous revisions - If the call has come from UMTS or VoIP without the calling party identification, it has been proceeded according to the last call in the Auto CLIP Routing table. Now it is proceeded according to the relevant ringing table.
4.08rev8
• !!! Fixed the bug in previous revisions - Called numbes have been incorrectly presented in the list of called numbers on the key phone (some of them missed last digits and the last number had an additional 0 at the end). This bug could cause incorrect behaviour of AutoCLIP Routing.
4.08rev7
• !!! Fixed the bug in 4.08rev5 - If the cumulative length of all Text fields (name of the Short dial) is longer than 20 characters, following records couldn’t be saved correctly. This bug influented correct behaviour of the Event report SMSs too. If you have such configuration of the Short dials table, use this revision (or later) if doing upgrade to version 4.08! Use the configuration tool version 4.08D!
• !!! WARNING !!! Save the PBX configuration before upgrade to FW 4.08rev7. This upgrade automatically does the factory reset!!!
4.08rev5
• SMS Event reporting - info about: settings ganges, link failure, the SIM card credit, switch status etc.)
• Binary switch actions - send user SMS, block phones, block external lines, day/night switching, close contact relay).
• CLIR function - select if call would be made with identification or not. Could be associated to the key on the key phone. LED diode next to the key shines if CLIR is aktive.
• Fixed: DTMF sometimes not sent correctly from key phone to ISDN line
• Auto CLIP Routing enable/disable for each internal line separatelly (Internal lines/Enabling of services)
4.07rev9
• Fixed: Incorrect routing of incoming calls from CO line - AutoCLIP Routing service has been erroneously activated even in case when call has come over the CO line without CLIP identification.
4.07rev8
• Fixed – It hasn’t be able to make a short dial from the system (key) phone using service 80xx (fw version 4.07rev6)
• Fixed error in the GSM module trace – occasionally it could be found a fake alarm message in GSM trace „Some SMSs could be lost“ even when everything was OK (fw version 4.07rev6)
4.07rev6
• Auto CLIP routing feature.
• Italian menu on key (system) phones
4.06rev25
• !!! Fixed the risk of blocking system (key) phones – in the previous versions the next call to the busy system phone could sometimes cause blocking (workaround was to disable Internal lines/Enabling of services/Whole/Action/Next call ringing) !!!
4.06rev24
• Turkish menu on key (system) phones
• Tracing of the communication to key (system) phones – needed FW 2.70, at the system phone module
• Long distance prefix activated - Example: The long distance prefix is set. e.g. „0“. New call comes from the local country. If CLIP contains the international prefix of the country, that prefix is removed (must be set in the Configuration Tool too) and replaced with the long distance prefix. The modified CLIP is sent to the phone display and could be used for call back.
4.06rev18
• Hungarian language pack.
• Support of the older GSM modul FW versions 1.01 – 2.02. Older revisions of firmware 4.06 didn’t support those versions
4.06rev15
• Change in the forwarding to external lines – If the message „call is forwarded“ isn’t enabled, an incoming call to an extension, which is forwarded to a PSTN number, will not be picked up before it would be picked up at that PSTN number. In the previous versions, message has always been enabled and billing started even before the last destination has picked that call.
• Added option in ISDN line settings: „Don’t send request for AOC“ – blocks sending of facility Invoke AOC in the ISDN setup message. The ISDN modul firmware version ISM 16.01 is needed. Configuration tool version 4.06L or higher is needed.
4.06rev13
• Fixed critical error - blocking of key phones (caused by dat.acc and dat.dia file download)
• Fixed - In the case of ringing of a few extensions, if one picked up others had missed call
• Fixed - ME enable/disable couldn't be done from the ME mobile phone
2N® Omega Lite/ 2N® Omega 48 – Firmware
Release Notes EN
26.07.2010
!!! WARNING !!!
Upgrade from the firmware version 4.05 or earlier to the firmware version 4.06 or higher has to be done from the configuration tool corresponding to the target firmware version i.e 4.06, 4.07 etc. When you try to upgrade it from one of older versions, it causes destruction of data in the PBX. Then, firmware has to be uploaded from the boot (service) mode. You can get to the service mode using the lower button on the left side of the PBX. For details see the manual.
!!! The correct upgrade procedure:
- make a backup of your configuration in your original config tool e.g. 4.05
- install the newest version of the config tool (4.06, 4.07, 4.08)
- do the upgrade of the firmware from the installed config tool (4.06, 4.07, 4.08)
- download config from the PBX in new config tool
- open your stored configuration in the originál config tool and rewrite it manualy to the new config tool
- upload configuration from the new config tool to PBX
4.08rev10
• Searching in phone directory on system (key) phones using up to 3 leading characters. After that, it is possible to scroll the whole directory using < and > buttons.
• !!! Fixed the bug in previous revisions - If the call has come from UMTS or VoIP without the calling party identification, it has been proceeded according to the last call in the Auto CLIP Routing table. Now it is proceeded according to the relevant ringing table.
4.08rev8
• !!! Fixed the bug in previous revisions - Called numbes have been incorrectly presented in the list of called numbers on the key phone (some of them missed last digits and the last number had an additional 0 at the end). This bug could cause incorrect behaviour of AutoCLIP Routing.
4.08rev7
• !!! Fixed the bug in 4.08rev5 - If the cumulative length of all Text fields (name of the Short dial) is longer than 20 characters, following records couldn’t be saved correctly. This bug influented correct behaviour of the Event report SMSs too. If you have such configuration of the Short dials table, use this revision (or later) if doing upgrade to version 4.08! Use the configuration tool version 4.08D!
• !!! WARNING !!! Save the PBX configuration before upgrade to FW 4.08rev7. This upgrade automatically does the factory reset!!!
4.08rev5
• SMS Event reporting - info about: settings ganges, link failure, the SIM card credit, switch status etc.)
• Binary switch actions - send user SMS, block phones, block external lines, day/night switching, close contact relay).
• CLIR function - select if call would be made with identification or not. Could be associated to the key on the key phone. LED diode next to the key shines if CLIR is aktive.
• Fixed: DTMF sometimes not sent correctly from key phone to ISDN line
• Auto CLIP Routing enable/disable for each internal line separatelly (Internal lines/Enabling of services)
4.07rev9
• Fixed: Incorrect routing of incoming calls from CO line - AutoCLIP Routing service has been erroneously activated even in case when call has come over the CO line without CLIP identification.
4.07rev8
• Fixed – It hasn’t be able to make a short dial from the system (key) phone using service 80xx (fw version 4.07rev6)
• Fixed error in the GSM module trace – occasionally it could be found a fake alarm message in GSM trace „Some SMSs could be lost“ even when everything was OK (fw version 4.07rev6)
4.07rev6
• Auto CLIP routing feature.
• Italian menu on key (system) phones
4.06rev25
• !!! Fixed the risk of blocking system (key) phones – in the previous versions the next call to the busy system phone could sometimes cause blocking (workaround was to disable Internal lines/Enabling of services/Whole/Action/Next call ringing) !!!
4.06rev24
• Turkish menu on key (system) phones
• Tracing of the communication to key (system) phones – needed FW 2.70, at the system phone module
• Long distance prefix activated - Example: The long distance prefix is set. e.g. „0“. New call comes from the local country. If CLIP contains the international prefix of the country, that prefix is removed (must be set in the Configuration Tool too) and replaced with the long distance prefix. The modified CLIP is sent to the phone display and could be used for call back.
4.06rev18
• Hungarian language pack.
• Support of the older GSM modul FW versions 1.01 – 2.02. Older revisions of firmware 4.06 didn’t support those versions
4.06rev15
• Change in the forwarding to external lines – If the message „call is forwarded“ isn’t enabled, an incoming call to an extension, which is forwarded to a PSTN number, will not be picked up before it would be picked up at that PSTN number. In the previous versions, message has always been enabled and billing started even before the last destination has picked that call.
• Added option in ISDN line settings: „Don’t send request for AOC“ – blocks sending of facility Invoke AOC in the ISDN setup message. The ISDN modul firmware version ISM 16.01 is needed. Configuration tool version 4.06L or higher is needed.
4.06rev13
• Fixed critical error - blocking of key phones (caused by dat.acc and dat.dia file download)
• Fixed - In the case of ringing of a few extensions, if one picked up others had missed call
• Fixed - ME enable/disable couldn't be done from the ME mobile phone
Release Notes EN
26.07.2010
!!! WARNING !!!
Upgrade from the firmware version 4.05 or earlier to the firmware version 4.06 or higher has to be done from the configuration tool corresponding to the target firmware version i.e 4.06, 4.07 etc. When you try to upgrade it from one of older versions, it causes destruction of data in the PBX. Then, firmware has to be uploaded from the boot (service) mode. You can get to the service mode using the lower button on the left side of the PBX. For details see the manual.
!!! The correct upgrade procedure:
- make a backup of your configuration in your original config tool e.g. 4.05
- install the newest version of the config tool (4.06, 4.07, 4.08)
- do the upgrade of the firmware from the installed config tool (4.06, 4.07, 4.08)
- download config from the PBX in new config tool
- open your stored configuration in the originál config tool and rewrite it manualy to the new config tool
- upload configuration from the new config tool to PBX
4.08rev10
• Searching in phone directory on system (key) phones using up to 3 leading characters. After that, it is possible to scroll the whole directory using < and > buttons.
• !!! Fixed the bug in previous revisions - If the call has come from UMTS or VoIP without the calling party identification, it has been proceeded according to the last call in the Auto CLIP Routing table. Now it is proceeded according to the relevant ringing table.
4.08rev8
• !!! Fixed the bug in previous revisions - Called numbes have been incorrectly presented in the list of called numbers on the key phone (some of them missed last digits and the last number had an additional 0 at the end). This bug could cause incorrect behaviour of AutoCLIP Routing.
4.08rev7
• !!! Fixed the bug in 4.08rev5 - If the cumulative length of all Text fields (name of the Short dial) is longer than 20 characters, following records couldn’t be saved correctly. This bug influented correct behaviour of the Event report SMSs too. If you have such configuration of the Short dials table, use this revision (or later) if doing upgrade to version 4.08! Use the configuration tool version 4.08D!
• !!! WARNING !!! Save the PBX configuration before upgrade to FW 4.08rev7. This upgrade automatically does the factory reset!!!
4.08rev5
• SMS Event reporting - info about: settings ganges, link failure, the SIM card credit, switch status etc.)
• Binary switch actions - send user SMS, block phones, block external lines, day/night switching, close contact relay).
• CLIR function - select if call would be made with identification or not. Could be associated to the key on the key phone. LED diode next to the key shines if CLIR is aktive.
• Fixed: DTMF sometimes not sent correctly from key phone to ISDN line
• Auto CLIP Routing enable/disable for each internal line separatelly (Internal lines/Enabling of services)
4.07rev9
• Fixed: Incorrect routing of incoming calls from CO line - AutoCLIP Routing service has been erroneously activated even in case when call has come over the CO line without CLIP identification.
4.07rev8
• Fixed – It hasn’t be able to make a short dial from the system (key) phone using service 80xx (fw version 4.07rev6)
• Fixed error in the GSM module trace – occasionally it could be found a fake alarm message in GSM trace „Some SMSs could be lost“ even when everything was OK (fw version 4.07rev6)
4.07rev6
• Auto CLIP routing feature.
• Italian menu on key (system) phones
4.06rev25
• !!! Fixed the risk of blocking system (key) phones – in the previous versions the next call to the busy system phone could sometimes cause blocking (workaround was to disable Internal lines/Enabling of services/Whole/Action/Next call ringing) !!!
4.06rev24
• Turkish menu on key (system) phones
• Tracing of the communication to key (system) phones – needed FW 2.70, at the system phone module
• Long distance prefix activated - Example: The long distance prefix is set. e.g. „0“. New call comes from the local country. If CLIP contains the international prefix of the country, that prefix is removed (must be set in the Configuration Tool too) and replaced with the long distance prefix. The modified CLIP is sent to the phone display and could be used for call back.
4.06rev18
• Hungarian language pack.
• Support of the older GSM modul FW versions 1.01 – 2.02. Older revisions of firmware 4.06 didn’t support those versions
4.06rev15
• Change in the forwarding to external lines – If the message „call is forwarded“ isn’t enabled, an incoming call to an extension, which is forwarded to a PSTN number, will not be picked up before it would be picked up at that PSTN number. In the previous versions, message has always been enabled and billing started even before the last destination has picked that call.
• Added option in ISDN line settings: „Don’t send request for AOC“ – blocks sending of facility Invoke AOC in the ISDN setup message. The ISDN modul firmware version ISM 16.01 is needed. Configuration tool version 4.06L or higher is needed.
4.06rev13
• Fixed critical error - blocking of key phones (caused by dat.acc and dat.dia file download)
• Fixed - In the case of ringing of a few extensions, if one picked up others had missed call
• Fixed - ME enable/disable couldn't be done from the ME mobile phone
2N® Omega Lite/ 2N® Omega 48 – Firmware
Release Notes EN
26.07.2010
!!! WARNING !!!
Upgrade from the firmware version 4.05 or earlier to the firmware version 4.06 or higher has to be done from the configuration tool corresponding to the target firmware version i.e 4.06, 4.07 etc. When you try to upgrade it from one of older versions, it causes destruction of data in the PBX. Then, firmware has to be uploaded from the boot (service) mode. You can get to the service mode using the lower button on the left side of the PBX. For details see the manual.
!!! The correct upgrade procedure:
- make a backup of your configuration in your original config tool e.g. 4.05
- install the newest version of the config tool (4.06, 4.07, 4.08)
- do the upgrade of the firmware from the installed config tool (4.06, 4.07, 4.08)
- download config from the PBX in new config tool
- open your stored configuration in the originál config tool and rewrite it manualy to the new config tool
- upload configuration from the new config tool to PBX
4.08rev10
• Searching in phone directory on system (key) phones using up to 3 leading characters. After that, it is possible to scroll the whole directory using < and > buttons.
• !!! Fixed the bug in previous revisions - If the call has come from UMTS or VoIP without the calling party identification, it has been proceeded according to the last call in the Auto CLIP Routing table. Now it is proceeded according to the relevant ringing table.
4.08rev8
• !!! Fixed the bug in previous revisions - Called numbes have been incorrectly presented in the list of called numbers on the key phone (some of them missed last digits and the last number had an additional 0 at the end). This bug could cause incorrect behaviour of AutoCLIP Routing.
4.08rev7
• !!! Fixed the bug in 4.08rev5 - If the cumulative length of all Text fields (name of the Short dial) is longer than 20 characters, following records couldn’t be saved correctly. This bug influented correct behaviour of the Event report SMSs too. If you have such configuration of the Short dials table, use this revision (or later) if doing upgrade to version 4.08! Use the configuration tool version 4.08D!
• !!! WARNING !!! Save the PBX configuration before upgrade to FW 4.08rev7. This upgrade automatically does the factory reset!!!
4.08rev5
• SMS Event reporting - info about: settings ganges, link failure, the SIM card credit, switch status etc.)
• Binary switch actions - send user SMS, block phones, block external lines, day/night switching, close contact relay).
• CLIR function - select if call would be made with identification or not. Could be associated to the key on the key phone. LED diode next to the key shines if CLIR is aktive.
• Fixed: DTMF sometimes not sent correctly from key phone to ISDN line
• Auto CLIP Routing enable/disable for each internal line separatelly (Internal lines/Enabling of services)
4.07rev9
• Fixed: Incorrect routing of incoming calls from CO line - AutoCLIP Routing service has been erroneously activated even in case when call has come over the CO line without CLIP identification.
4.07rev8
• Fixed – It hasn’t be able to make a short dial from the system (key) phone using service 80xx (fw version 4.07rev6)
• Fixed error in the GSM module trace – occasionally it could be found a fake alarm message in GSM trace „Some SMSs could be lost“ even when everything was OK (fw version 4.07rev6)
4.07rev6
• Auto CLIP routing feature.
• Italian menu on key (system) phones
4.06rev25
• !!! Fixed the risk of blocking system (key) phones – in the previous versions the next call to the busy system phone could sometimes cause blocking (workaround was to disable Internal lines/Enabling of services/Whole/Action/Next call ringing) !!!
4.06rev24
• Turkish menu on key (system) phones
• Tracing of the communication to key (system) phones – needed FW 2.70, at the system phone module
• Long distance prefix activated - Example: The long distance prefix is set. e.g. „0“. New call comes from the local country. If CLIP contains the international prefix of the country, that prefix is removed (must be set in the Configuration Tool too) and replaced with the long distance prefix. The modified CLIP is sent to the phone display and could be used for call back.
4.06rev18
• Hungarian language pack.
• Support of the older GSM modul FW versions 1.01 – 2.02. Older revisions of firmware 4.06 didn’t support those versions
4.06rev15
• Change in the forwarding to external lines – If the message „call is forwarded“ isn’t enabled, an incoming call to an extension, which is forwarded to a PSTN number, will not be picked up before it would be picked up at that PSTN number. In the previous versions, message has always been enabled and billing started even before the last destination has picked that call.
• Added option in ISDN line settings: „Don’t send request for AOC“ – blocks sending of facility Invoke AOC in the ISDN setup message. The ISDN modul firmware version ISM 16.01 is needed. Configuration tool version 4.06L or higher is needed.
4.06rev13
• Fixed critical error - blocking of key phones (caused by dat.acc and dat.dia file download)
• Fixed - In the case of ringing of a few extensions, if one picked up others had missed call
• Fixed - ME enable/disable couldn't be done from the ME mobile phone
Release Notes EN
26.07.2010
!!! WARNING !!!
Upgrade from the firmware version 4.05 or earlier to the firmware version 4.06 or higher has to be done from the configuration tool corresponding to the target firmware version i.e 4.06, 4.07 etc. When you try to upgrade it from one of older versions, it causes destruction of data in the PBX. Then, firmware has to be uploaded from the boot (service) mode. You can get to the service mode using the lower button on the left side of the PBX. For details see the manual.
!!! The correct upgrade procedure:
- make a backup of your configuration in your original config tool e.g. 4.05
- install the newest version of the config tool (4.06, 4.07, 4.08)
- do the upgrade of the firmware from the installed config tool (4.06, 4.07, 4.08)
- download config from the PBX in new config tool
- open your stored configuration in the originál config tool and rewrite it manualy to the new config tool
- upload configuration from the new config tool to PBX
4.08rev10
• Searching in phone directory on system (key) phones using up to 3 leading characters. After that, it is possible to scroll the whole directory using < and > buttons.
• !!! Fixed the bug in previous revisions - If the call has come from UMTS or VoIP without the calling party identification, it has been proceeded according to the last call in the Auto CLIP Routing table. Now it is proceeded according to the relevant ringing table.
4.08rev8
• !!! Fixed the bug in previous revisions - Called numbes have been incorrectly presented in the list of called numbers on the key phone (some of them missed last digits and the last number had an additional 0 at the end). This bug could cause incorrect behaviour of AutoCLIP Routing.
4.08rev7
• !!! Fixed the bug in 4.08rev5 - If the cumulative length of all Text fields (name of the Short dial) is longer than 20 characters, following records couldn’t be saved correctly. This bug influented correct behaviour of the Event report SMSs too. If you have such configuration of the Short dials table, use this revision (or later) if doing upgrade to version 4.08! Use the configuration tool version 4.08D!
• !!! WARNING !!! Save the PBX configuration before upgrade to FW 4.08rev7. This upgrade automatically does the factory reset!!!
4.08rev5
• SMS Event reporting - info about: settings ganges, link failure, the SIM card credit, switch status etc.)
• Binary switch actions - send user SMS, block phones, block external lines, day/night switching, close contact relay).
• CLIR function - select if call would be made with identification or not. Could be associated to the key on the key phone. LED diode next to the key shines if CLIR is aktive.
• Fixed: DTMF sometimes not sent correctly from key phone to ISDN line
• Auto CLIP Routing enable/disable for each internal line separatelly (Internal lines/Enabling of services)
4.07rev9
• Fixed: Incorrect routing of incoming calls from CO line - AutoCLIP Routing service has been erroneously activated even in case when call has come over the CO line without CLIP identification.
4.07rev8
• Fixed – It hasn’t be able to make a short dial from the system (key) phone using service 80xx (fw version 4.07rev6)
• Fixed error in the GSM module trace – occasionally it could be found a fake alarm message in GSM trace „Some SMSs could be lost“ even when everything was OK (fw version 4.07rev6)
4.07rev6
• Auto CLIP routing feature.
• Italian menu on key (system) phones
4.06rev25
• !!! Fixed the risk of blocking system (key) phones – in the previous versions the next call to the busy system phone could sometimes cause blocking (workaround was to disable Internal lines/Enabling of services/Whole/Action/Next call ringing) !!!
4.06rev24
• Turkish menu on key (system) phones
• Tracing of the communication to key (system) phones – needed FW 2.70, at the system phone module
• Long distance prefix activated - Example: The long distance prefix is set. e.g. „0“. New call comes from the local country. If CLIP contains the international prefix of the country, that prefix is removed (must be set in the Configuration Tool too) and replaced with the long distance prefix. The modified CLIP is sent to the phone display and could be used for call back.
4.06rev18
• Hungarian language pack.
• Support of the older GSM modul FW versions 1.01 – 2.02. Older revisions of firmware 4.06 didn’t support those versions
4.06rev15
• Change in the forwarding to external lines – If the message „call is forwarded“ isn’t enabled, an incoming call to an extension, which is forwarded to a PSTN number, will not be picked up before it would be picked up at that PSTN number. In the previous versions, message has always been enabled and billing started even before the last destination has picked that call.
• Added option in ISDN line settings: „Don’t send request for AOC“ – blocks sending of facility Invoke AOC in the ISDN setup message. The ISDN modul firmware version ISM 16.01 is needed. Configuration tool version 4.06L or higher is needed.
4.06rev13
• Fixed critical error - blocking of key phones (caused by dat.acc and dat.dia file download)
• Fixed - In the case of ringing of a few extensions, if one picked up others had missed call
• Fixed - ME enable/disable couldn't be done from the ME mobile phone
2N® Omega Lite/ 2N® Omega 48 – Firmware
Release Notes EN
19.07.2010
!!! WARNING !!!
Upgrade from the firmware version 4.05 or earlier to the firmware version 4.06 or higher has to be done from the configuration tool corresponding to the target firmware version i.e 4.06, 4.07 etc. When you try to upgrade it from one of older versions, it causes destruction of data in the PBX. Then, firmware has to be uploaded from the boot (service) mode. You can get to the service mode using the lower button on the left side of the PBX. For details see the manual.
!!! The correct upgrade procedure:
- make a backup of your configuration in your original config tool e.g. 4.05
- install the newest version of the config tool (4.06, 4.07, 4.08)
- do the upgrade of the firmware from the installed config tool (4.06, 4.07, 4.08)
- download config from the PBX in new config tool
- open your stored configuration in the originál config tool and rewrite it manualy to the new config tool
- upload configuration from the new config tool to PBX
4.08rev8
• !!! Fixed the bug in previous revisions - Called numbes have been incorrectly presented in the list of called numbers on the key phone (some of them missed last digits and the last number had an additional 0 at the end). This bug could cause incorrect behaviour of AutoCLIP Routing.
4.08rev7
• !!! Fixed the bug in 4.08rev5 - If the cumulative length of all Text fields (name of the Short dial) is longer than 20 characters, following records couldn’t be saved correctly. This bug influented correct behaviour of the Event report SMSs too. If you have such configuration of the Short dials table, use this revision (or later) if doing upgrade to version 4.08! Use the configuration tool version 4.08D!
• !!! WARNING !!! Save the PBX configuration before upgrade to FW 4.08rev7. This upgrade automatically does the factory reset!!!
4.08rev5
• SMS Event reporting - info about: settings ganges, link failure, the SIM card credit, switch status etc.)
• Binary switch actions - send user SMS, block phones, block external lines, day/night switching, close contact relay).
• CLIR function - select if call would be made with identification or not. Could be associated to the key on the key phone. LED diode next to the key shines if CLIR is aktive.
• Fixed: DTMF sometimes not sent correctly from key phone to ISDN line
• Auto CLIP Routing enable/disable for each internal line separatelly (Internal lines/Enabling of services)
4.07rev9
• Fixed: Incorrect routing of incoming calls from CO line - AutoCLIP Routing service has been erroneously activated even in case when call has come over the CO line without CLIP identification.
4.07rev8
• Fixed – It hasn’t be able to make a short dial from the system (key) phone using service 80xx (fw version 4.07rev6)
• Fixed error in the GSM module trace – occasionally it could be found a fake alarm message in GSM trace „Some SMSs could be lost“ even when everything was OK (fw version 4.07rev6)
4.07rev6
• Auto CLIP routing feature.
• Italian menu on key (system) phones
4.06rev25
• !!! Fixed the risk of blocking system (key) phones – in the previous versions the next call to the busy system phone could sometimes cause blocking (workaround was to disable Internal lines/Enabling of services/Whole/Action/Next call ringing) !!!
4.06rev24
• Turkish menu on key (system) phones
• Tracing of the communication to key (system) phones – needed FW 2.70, at the system phone module
• Long distance prefix activated - Example: The long distance prefix is set. e.g. „0“. New call comes from the local country. If CLIP contains the international prefix of the country, that prefix is removed (must be set in the Configuration Tool too) and replaced with the long distance prefix. The modified CLIP is sent to the phone display and could be used for call back.
4.06rev18
• Hungarian language pack.
• Support of the older GSM modul FW versions 1.01 – 2.02. Older revisions of firmware 4.06 didn’t support those versions
4.06rev15
• Change in the forwarding to external lines – If the message „call is forwarded“ isn’t enabled, an incoming call to an extension, which is forwarded to a PSTN number, will not be picked up before it would be picked up at that PSTN number. In the previous versions, message has always been enabled and billing started even before the last destination has picked that call.
• Added option in ISDN line settings: „Don’t send request for AOC“ – blocks sending of facility Invoke AOC in the ISDN setup message. The ISDN modul firmware version ISM 16.01 is needed. Configuration tool version 4.06L or higher is needed.
4.06rev13
• Fixed critical error - blocking of key phones (caused by dat.acc and dat.dia file download)
• Fixed - In the case of ringing of a few extensions, if one picked up others had missed call
• Fixed - ME enable/disable couldn't be done from the ME mobile phone
Release Notes EN
19.07.2010
!!! WARNING !!!
Upgrade from the firmware version 4.05 or earlier to the firmware version 4.06 or higher has to be done from the configuration tool corresponding to the target firmware version i.e 4.06, 4.07 etc. When you try to upgrade it from one of older versions, it causes destruction of data in the PBX. Then, firmware has to be uploaded from the boot (service) mode. You can get to the service mode using the lower button on the left side of the PBX. For details see the manual.
!!! The correct upgrade procedure:
- make a backup of your configuration in your original config tool e.g. 4.05
- install the newest version of the config tool (4.06, 4.07, 4.08)
- do the upgrade of the firmware from the installed config tool (4.06, 4.07, 4.08)
- download config from the PBX in new config tool
- open your stored configuration in the originál config tool and rewrite it manualy to the new config tool
- upload configuration from the new config tool to PBX
4.08rev8
• !!! Fixed the bug in previous revisions - Called numbes have been incorrectly presented in the list of called numbers on the key phone (some of them missed last digits and the last number had an additional 0 at the end). This bug could cause incorrect behaviour of AutoCLIP Routing.
4.08rev7
• !!! Fixed the bug in 4.08rev5 - If the cumulative length of all Text fields (name of the Short dial) is longer than 20 characters, following records couldn’t be saved correctly. This bug influented correct behaviour of the Event report SMSs too. If you have such configuration of the Short dials table, use this revision (or later) if doing upgrade to version 4.08! Use the configuration tool version 4.08D!
• !!! WARNING !!! Save the PBX configuration before upgrade to FW 4.08rev7. This upgrade automatically does the factory reset!!!
4.08rev5
• SMS Event reporting - info about: settings ganges, link failure, the SIM card credit, switch status etc.)
• Binary switch actions - send user SMS, block phones, block external lines, day/night switching, close contact relay).
• CLIR function - select if call would be made with identification or not. Could be associated to the key on the key phone. LED diode next to the key shines if CLIR is aktive.
• Fixed: DTMF sometimes not sent correctly from key phone to ISDN line
• Auto CLIP Routing enable/disable for each internal line separatelly (Internal lines/Enabling of services)
4.07rev9
• Fixed: Incorrect routing of incoming calls from CO line - AutoCLIP Routing service has been erroneously activated even in case when call has come over the CO line without CLIP identification.
4.07rev8
• Fixed – It hasn’t be able to make a short dial from the system (key) phone using service 80xx (fw version 4.07rev6)
• Fixed error in the GSM module trace – occasionally it could be found a fake alarm message in GSM trace „Some SMSs could be lost“ even when everything was OK (fw version 4.07rev6)
4.07rev6
• Auto CLIP routing feature.
• Italian menu on key (system) phones
4.06rev25
• !!! Fixed the risk of blocking system (key) phones – in the previous versions the next call to the busy system phone could sometimes cause blocking (workaround was to disable Internal lines/Enabling of services/Whole/Action/Next call ringing) !!!
4.06rev24
• Turkish menu on key (system) phones
• Tracing of the communication to key (system) phones – needed FW 2.70, at the system phone module
• Long distance prefix activated - Example: The long distance prefix is set. e.g. „0“. New call comes from the local country. If CLIP contains the international prefix of the country, that prefix is removed (must be set in the Configuration Tool too) and replaced with the long distance prefix. The modified CLIP is sent to the phone display and could be used for call back.
4.06rev18
• Hungarian language pack.
• Support of the older GSM modul FW versions 1.01 – 2.02. Older revisions of firmware 4.06 didn’t support those versions
4.06rev15
• Change in the forwarding to external lines – If the message „call is forwarded“ isn’t enabled, an incoming call to an extension, which is forwarded to a PSTN number, will not be picked up before it would be picked up at that PSTN number. In the previous versions, message has always been enabled and billing started even before the last destination has picked that call.
• Added option in ISDN line settings: „Don’t send request for AOC“ – blocks sending of facility Invoke AOC in the ISDN setup message. The ISDN modul firmware version ISM 16.01 is needed. Configuration tool version 4.06L or higher is needed.
4.06rev13
• Fixed critical error - blocking of key phones (caused by dat.acc and dat.dia file download)
• Fixed - In the case of ringing of a few extensions, if one picked up others had missed call
• Fixed - ME enable/disable couldn't be done from the ME mobile phone
2N® Omega Lite/ 2N® Omega 48 – Firmware
Release Notes EN
19.07.2010
!!! WARNING !!!
Upgrade from the firmware version 4.05 or earlier to the firmware version 4.06 or higher has to be done from the configuration tool corresponding to the target firmware version i.e 4.06, 4.07 etc. When you try to upgrade it from one of older versions, it causes destruction of data in the PBX. Then, firmware has to be uploaded from the boot (service) mode. You can get to the service mode using the lower button on the left side of the PBX. For details see the manual.
!!! The correct upgrade procedure:
- make a backup of your configuration in your original config tool e.g. 4.05
- install the newest version of the config tool (4.06, 4.07, 4.08)
- do the upgrade of the firmware from the installed config tool (4.06, 4.07, 4.08)
- download config from the PBX in new config tool
- open your stored configuration in the originál config tool and rewrite it manualy to the new config tool
- upload configuration from the new config tool to PBX
4.08rev8
• !!! Fixed the bug in previous revisions - Called numbes have been incorrectly presented in the list of called numbers on the key phone (some of them missed last digits and the last number had an additional 0 at the end). This bug could cause incorrect behaviour of AutoCLIP Routing.
4.08rev7
• !!! Fixed the bug in 4.08rev5 - If the cumulative length of all Text fields (name of the Short dial) is longer than 20 characters, following records couldn’t be saved correctly. This bug influented correct behaviour of the Event report SMSs too. If you have such configuration of the Short dials table, use this revision (or later) if doing upgrade to version 4.08! Use the configuration tool version 4.08D!
• !!! WARNING !!! Save the PBX configuration before upgrade to FW 4.08rev7. This upgrade automatically does the factory reset!!!
4.08rev5
• SMS Event reporting - info about: settings ganges, link failure, the SIM card credit, switch status etc.)
• Binary switch actions - send user SMS, block phones, block external lines, day/night switching, close contact relay).
• CLIR function - select if call would be made with identification or not. Could be associated to the key on the key phone. LED diode next to the key shines if CLIR is aktive.
• Fixed: DTMF sometimes not sent correctly from key phone to ISDN line
• Auto CLIP Routing enable/disable for each internal line separatelly (Internal lines/Enabling of services)
4.07rev9
• Fixed: Incorrect routing of incoming calls from CO line - AutoCLIP Routing service has been erroneously activated even in case when call has come over the CO line without CLIP identification.
4.07rev8
• Fixed – It hasn’t be able to make a short dial from the system (key) phone using service 80xx (fw version 4.07rev6)
• Fixed error in the GSM module trace – occasionally it could be found a fake alarm message in GSM trace „Some SMSs could be lost“ even when everything was OK (fw version 4.07rev6)
4.07rev6
• Auto CLIP routing feature.
• Italian menu on key (system) phones
4.06rev25
• !!! Fixed the risk of blocking system (key) phones – in the previous versions the next call to the busy system phone could sometimes cause blocking (workaround was to disable Internal lines/Enabling of services/Whole/Action/Next call ringing) !!!
4.06rev24
• Turkish menu on key (system) phones
• Tracing of the communication to key (system) phones – needed FW 2.70, at the system phone module
• Long distance prefix activated - Example: The long distance prefix is set. e.g. „0“. New call comes from the local country. If CLIP contains the international prefix of the country, that prefix is removed (must be set in the Configuration Tool too) and replaced with the long distance prefix. The modified CLIP is sent to the phone display and could be used for call back.
4.06rev18
• Hungarian language pack.
• Support of the older GSM modul FW versions 1.01 – 2.02. Older revisions of firmware 4.06 didn’t support those versions
4.06rev15
• Change in the forwarding to external lines – If the message „call is forwarded“ isn’t enabled, an incoming call to an extension, which is forwarded to a PSTN number, will not be picked up before it would be picked up at that PSTN number. In the previous versions, message has always been enabled and billing started even before the last destination has picked that call.
• Added option in ISDN line settings: „Don’t send request for AOC“ – blocks sending of facility Invoke AOC in the ISDN setup message. The ISDN modul firmware version ISM 16.01 is needed. Configuration tool version 4.06L or higher is needed.
4.06rev13
• Fixed critical error - blocking of key phones (caused by dat.acc and dat.dia file download)
• Fixed - In the case of ringing of a few extensions, if one picked up others had missed call
• Fixed - ME enable/disable couldn't be done from the ME mobile phone
Release Notes EN
19.07.2010
!!! WARNING !!!
Upgrade from the firmware version 4.05 or earlier to the firmware version 4.06 or higher has to be done from the configuration tool corresponding to the target firmware version i.e 4.06, 4.07 etc. When you try to upgrade it from one of older versions, it causes destruction of data in the PBX. Then, firmware has to be uploaded from the boot (service) mode. You can get to the service mode using the lower button on the left side of the PBX. For details see the manual.
!!! The correct upgrade procedure:
- make a backup of your configuration in your original config tool e.g. 4.05
- install the newest version of the config tool (4.06, 4.07, 4.08)
- do the upgrade of the firmware from the installed config tool (4.06, 4.07, 4.08)
- download config from the PBX in new config tool
- open your stored configuration in the originál config tool and rewrite it manualy to the new config tool
- upload configuration from the new config tool to PBX
4.08rev8
• !!! Fixed the bug in previous revisions - Called numbes have been incorrectly presented in the list of called numbers on the key phone (some of them missed last digits and the last number had an additional 0 at the end). This bug could cause incorrect behaviour of AutoCLIP Routing.
4.08rev7
• !!! Fixed the bug in 4.08rev5 - If the cumulative length of all Text fields (name of the Short dial) is longer than 20 characters, following records couldn’t be saved correctly. This bug influented correct behaviour of the Event report SMSs too. If you have such configuration of the Short dials table, use this revision (or later) if doing upgrade to version 4.08! Use the configuration tool version 4.08D!
• !!! WARNING !!! Save the PBX configuration before upgrade to FW 4.08rev7. This upgrade automatically does the factory reset!!!
4.08rev5
• SMS Event reporting - info about: settings ganges, link failure, the SIM card credit, switch status etc.)
• Binary switch actions - send user SMS, block phones, block external lines, day/night switching, close contact relay).
• CLIR function - select if call would be made with identification or not. Could be associated to the key on the key phone. LED diode next to the key shines if CLIR is aktive.
• Fixed: DTMF sometimes not sent correctly from key phone to ISDN line
• Auto CLIP Routing enable/disable for each internal line separatelly (Internal lines/Enabling of services)
4.07rev9
• Fixed: Incorrect routing of incoming calls from CO line - AutoCLIP Routing service has been erroneously activated even in case when call has come over the CO line without CLIP identification.
4.07rev8
• Fixed – It hasn’t be able to make a short dial from the system (key) phone using service 80xx (fw version 4.07rev6)
• Fixed error in the GSM module trace – occasionally it could be found a fake alarm message in GSM trace „Some SMSs could be lost“ even when everything was OK (fw version 4.07rev6)
4.07rev6
• Auto CLIP routing feature.
• Italian menu on key (system) phones
4.06rev25
• !!! Fixed the risk of blocking system (key) phones – in the previous versions the next call to the busy system phone could sometimes cause blocking (workaround was to disable Internal lines/Enabling of services/Whole/Action/Next call ringing) !!!
4.06rev24
• Turkish menu on key (system) phones
• Tracing of the communication to key (system) phones – needed FW 2.70, at the system phone module
• Long distance prefix activated - Example: The long distance prefix is set. e.g. „0“. New call comes from the local country. If CLIP contains the international prefix of the country, that prefix is removed (must be set in the Configuration Tool too) and replaced with the long distance prefix. The modified CLIP is sent to the phone display and could be used for call back.
4.06rev18
• Hungarian language pack.
• Support of the older GSM modul FW versions 1.01 – 2.02. Older revisions of firmware 4.06 didn’t support those versions
4.06rev15
• Change in the forwarding to external lines – If the message „call is forwarded“ isn’t enabled, an incoming call to an extension, which is forwarded to a PSTN number, will not be picked up before it would be picked up at that PSTN number. In the previous versions, message has always been enabled and billing started even before the last destination has picked that call.
• Added option in ISDN line settings: „Don’t send request for AOC“ – blocks sending of facility Invoke AOC in the ISDN setup message. The ISDN modul firmware version ISM 16.01 is needed. Configuration tool version 4.06L or higher is needed.
4.06rev13
• Fixed critical error - blocking of key phones (caused by dat.acc and dat.dia file download)
• Fixed - In the case of ringing of a few extensions, if one picked up others had missed call
• Fixed - ME enable/disable couldn't be done from the ME mobile phone
Extract the language pack suitable to you:
- Czech
- English
- Dutch (NL)
Upload it using web menu Telephony services --- Devices --- DISA Lines, button with envelope in lower right corner.
- Czech
- English
- Dutch (NL)
Upload it using web menu Telephony services --- Devices --- DISA Lines, button with envelope in lower right corner.
2N® Omega Lite / 2N® Omega 48 - Ethernet module firmware
Release Notes
19.05.2010
OLI-2-3-7 2010-05-19
• Mobility Extension on SIP extensions !!! Incoming ME on SIP extensions works only if the call comes from the basic part of Omega Lite/ Omega 48 i.e. from GSM, ISDN or CO lines !!!
• Music-on-hold
• Maximal DISA length enlarged to 500kB
• CLIR service (Calling Line Identification Restriction) when calling over SIP lines (header Privacy: id)
• PPPoE – connection to Internet over ADSL modem or router in bridged mode
• Sending USSD messages over the UMTS module
• XAPI 2.01S
OLI-2-3-6 2010-02-21
• This version is displayed in web configuration interface as 2.3.6a
• !!! Fixed the critical bug – Calling from VoIP to analogue or system phone extension, that has an active voicemail, calling party could listen messages left in the called party voice mailbox. (since firmware 2.3.2)
• Xapi 2.01N
OLI-2-3-5 2009-12-23
• Backup of configuration contains only configuration folders
• Web interface – the lower left angle icons are unified in various menus
• XAPI 2.01J – fixed problem of firmware upgrade from the configuration tool, over port 1234
• PPP – significantly improved uplink data rate over UMTS module
• Web interface - improved response time
• Ring Groups - VoIP phones (extensions) could be rang together
• new default password of Admin is 2n
• DNS – fixed problem of cyclical rebooting of Ethernet module – It happened if DNS proxy was enabled and DNS servers haven’t been set
• SIP - header Diversion
• Fixed the problem with Sierra module – if RING has come during SMS sending, SMS was treated as not sent
• Voicemail – warning about almost filled up message space
OLI-2-3-2 2009-11-04
• DISA message in Ethernet module – new settings – fall to the default operator, maximal duration of the voice mail message, improved voice quality of messages
• Listen port displayed in the SIP lines menu
• H.323 – the calling party identification in incomming calls- corrected
• QoS indication could be set for RTP and SIP
• XAPI 2.01H
OLI-2-3-1 2009-09-23
• integrated XAPI server
• new, more reliable H.323 stack
• DISA - interdigit timeout, limited call duration, cycling limit
• default IP address 192.168.1.1
Release Notes
19.05.2010
OLI-2-3-7 2010-05-19
• Mobility Extension on SIP extensions !!! Incoming ME on SIP extensions works only if the call comes from the basic part of Omega Lite/ Omega 48 i.e. from GSM, ISDN or CO lines !!!
• Music-on-hold
• Maximal DISA length enlarged to 500kB
• CLIR service (Calling Line Identification Restriction) when calling over SIP lines (header Privacy: id)
• PPPoE – connection to Internet over ADSL modem or router in bridged mode
• Sending USSD messages over the UMTS module
• XAPI 2.01S
OLI-2-3-6 2010-02-21
• This version is displayed in web configuration interface as 2.3.6a
• !!! Fixed the critical bug – Calling from VoIP to analogue or system phone extension, that has an active voicemail, calling party could listen messages left in the called party voice mailbox. (since firmware 2.3.2)
• Xapi 2.01N
OLI-2-3-5 2009-12-23
• Backup of configuration contains only configuration folders
• Web interface – the lower left angle icons are unified in various menus
• XAPI 2.01J – fixed problem of firmware upgrade from the configuration tool, over port 1234
• PPP – significantly improved uplink data rate over UMTS module
• Web interface - improved response time
• Ring Groups - VoIP phones (extensions) could be rang together
• new default password of Admin is 2n
• DNS – fixed problem of cyclical rebooting of Ethernet module – It happened if DNS proxy was enabled and DNS servers haven’t been set
• SIP - header Diversion
• Fixed the problem with Sierra module – if RING has come during SMS sending, SMS was treated as not sent
• Voicemail – warning about almost filled up message space
OLI-2-3-2 2009-11-04
• DISA message in Ethernet module – new settings – fall to the default operator, maximal duration of the voice mail message, improved voice quality of messages
• Listen port displayed in the SIP lines menu
• H.323 – the calling party identification in incomming calls- corrected
• QoS indication could be set for RTP and SIP
• XAPI 2.01H
OLI-2-3-1 2009-09-23
• integrated XAPI server
• new, more reliable H.323 stack
• DISA - interdigit timeout, limited call duration, cycling limit
• default IP address 192.168.1.1
2N® Omega Lite/ 2N® Omega 48 – Firmware
Release Notes EN
05.05.2010
!!! CAUTION !!!
Upgrade from the firmware version 4.05 or earlier to the firmware version 4.06 or higher has to be done from the configuration tool corresponding to the target firmware version i.e 4.06, 4.07 etc. When you try to upgrade it from one of older versions, it causes destruction of data in the PBX. Then, firmware has to be uploaded from the boot (service) mode. You can get to the service mode using the lower button on the left side of the PBX. For details see the manual.
!!! The correct upgrade procedure:
- make a backup of your configuration in your original config tool e.g. 4.05
- install the newest version of the config tool (4.06, 4.07)
- do the upgrade of the firmware from the installed config tool (4.06, 4.07)
- download config from the PBX in new config tool
- open your stored configuration in the originál config tool and rewrite it manualy to the new config tool
- upload configuration from the new config tool to PBX
4.08rev5
• SMS Event reporting - info about: settings ganges, link failure, the SIM card credit, switch status etc.)
• Binary switch actions - send user SMS, block phones, block external lines, day/night switching, close contact relay).
• CLIR function - select if call would be made with identification or not. Could be associated to the key on the key phone. LED diode next to the key shines if CLIR is aktive.
• Fixed: DTMF sometimes not sent correctly from key phone to ISDN line
• Auto CLIP Routing enable/disable for each internal line separatelly (Internal lines/Enabling of services)
4.07rev9
• Fixed: Incorrect routing of incoming calls from CO line - AutoCLIP Routing service has been erroneously activated even in case when call has come over the CO line without CLIP identification.
4.07rev8
• Fixed – It hasn’t be able to make a short dial from the system (key) phone using service 80xx (fw version 4.07rev6)
• Fixed error in the GSM module trace – occasionally it could be found a fake alarm message in GSM trace „Some SMSs could be lost“ even when everything was OK (fw version 4.07rev6)
4.07rev6
• Auto CLIP routing feature.
• Italian menu on key (system) phones
4.06rev25
• !!! Fixed the risk of blocking system (key) phones – in the previous versions the next call to the busy system phone could sometimes cause blocking (workaround was to disable Internal lines/Enabling of services/Whole/Action/Next call ringing) !!!
4.06rev24
• Turkish menu on key (system) phones
• Tracing of the communication to key (system) phones – needed FW 2.70, at the system phone module
• Long distance prefix activated - Example: The long distance prefix is set. e.g. „0“. New call comes from the local country. If CLIP contains the international prefix of the country, that prefix is removed (must be set in the Configuration Tool too) and replaced with the long distance prefix. The modified CLIP is sent to the phone display and could be used for call back.
4.06rev18
• Hungarian language pack.
• Support of the older GSM modul FW versions 1.01 – 2.02. Older revisions of firmware 4.06 didn’t support those versions
4.06rev15
• Change in the forwarding to external lines – If the message „call is forwarded“ isn’t enabled, an incoming call to an extension, which is forwarded to a PSTN number, will not be picked up before it would be picked up at that PSTN number. In the previous versions, message has always been enabled and billing started even before the last destination has picked that call.
• Added option in ISDN line settings: „Don’t send request for AOC“ – blocks sending of facility Invoke AOC in the ISDN setup message. The ISDN modul firmware version ISM 16.01 is needed. Configuration tool version 4.06L or higher is needed.
4.06rev13
• Fixed critical error - blocking of key phones (caused by dat.acc and dat.dia file download)
• Fixed - In the case of ringing of a few extensions, if one picked up others had missed call
• Fixed - ME enable/disable couldn't be done from the ME mobile phone
Release Notes EN
05.05.2010
!!! CAUTION !!!
Upgrade from the firmware version 4.05 or earlier to the firmware version 4.06 or higher has to be done from the configuration tool corresponding to the target firmware version i.e 4.06, 4.07 etc. When you try to upgrade it from one of older versions, it causes destruction of data in the PBX. Then, firmware has to be uploaded from the boot (service) mode. You can get to the service mode using the lower button on the left side of the PBX. For details see the manual.
!!! The correct upgrade procedure:
- make a backup of your configuration in your original config tool e.g. 4.05
- install the newest version of the config tool (4.06, 4.07)
- do the upgrade of the firmware from the installed config tool (4.06, 4.07)
- download config from the PBX in new config tool
- open your stored configuration in the originál config tool and rewrite it manualy to the new config tool
- upload configuration from the new config tool to PBX
4.08rev5
• SMS Event reporting - info about: settings ganges, link failure, the SIM card credit, switch status etc.)
• Binary switch actions - send user SMS, block phones, block external lines, day/night switching, close contact relay).
• CLIR function - select if call would be made with identification or not. Could be associated to the key on the key phone. LED diode next to the key shines if CLIR is aktive.
• Fixed: DTMF sometimes not sent correctly from key phone to ISDN line
• Auto CLIP Routing enable/disable for each internal line separatelly (Internal lines/Enabling of services)
4.07rev9
• Fixed: Incorrect routing of incoming calls from CO line - AutoCLIP Routing service has been erroneously activated even in case when call has come over the CO line without CLIP identification.
4.07rev8
• Fixed – It hasn’t be able to make a short dial from the system (key) phone using service 80xx (fw version 4.07rev6)
• Fixed error in the GSM module trace – occasionally it could be found a fake alarm message in GSM trace „Some SMSs could be lost“ even when everything was OK (fw version 4.07rev6)
4.07rev6
• Auto CLIP routing feature.
• Italian menu on key (system) phones
4.06rev25
• !!! Fixed the risk of blocking system (key) phones – in the previous versions the next call to the busy system phone could sometimes cause blocking (workaround was to disable Internal lines/Enabling of services/Whole/Action/Next call ringing) !!!
4.06rev24
• Turkish menu on key (system) phones
• Tracing of the communication to key (system) phones – needed FW 2.70, at the system phone module
• Long distance prefix activated - Example: The long distance prefix is set. e.g. „0“. New call comes from the local country. If CLIP contains the international prefix of the country, that prefix is removed (must be set in the Configuration Tool too) and replaced with the long distance prefix. The modified CLIP is sent to the phone display and could be used for call back.
4.06rev18
• Hungarian language pack.
• Support of the older GSM modul FW versions 1.01 – 2.02. Older revisions of firmware 4.06 didn’t support those versions
4.06rev15
• Change in the forwarding to external lines – If the message „call is forwarded“ isn’t enabled, an incoming call to an extension, which is forwarded to a PSTN number, will not be picked up before it would be picked up at that PSTN number. In the previous versions, message has always been enabled and billing started even before the last destination has picked that call.
• Added option in ISDN line settings: „Don’t send request for AOC“ – blocks sending of facility Invoke AOC in the ISDN setup message. The ISDN modul firmware version ISM 16.01 is needed. Configuration tool version 4.06L or higher is needed.
4.06rev13
• Fixed critical error - blocking of key phones (caused by dat.acc and dat.dia file download)
• Fixed - In the case of ringing of a few extensions, if one picked up others had missed call
• Fixed - ME enable/disable couldn't be done from the ME mobile phone
2N® Omega Lite/ 2N® Omega 48 – Firmware
Release Notes EN
15.03.2010
!!! CAUTION !!!
Upgrade from the firmware version 4.05 or earlier to the firmware version 4.06 or higher has to be done from the configuration tool corresponding to the target firmware version i.e 4.06, 4.07 etc. When you try to upgrade it from one of older versions, it causes destruction of data in the PBX. Then, firmware has to be uploaded from the boot (service) mode. You can get to the service mode using the lower button on the left side of the PBX. For details see the manual.
!!! The correct upgrade procedure:
- make a backup of your configuration in your previous config tool
- install the newest version of the config tool (4.06, 4.07)
- do the upgrade of the firmware from the installed config tool (4.06, 4.07)
- download config from the PBX, open your stored configuration, upload it to the PBX or rewrite it manuály
4.07rev9
• Fixed: Incorrect routing of incoming calls from CO line - AutoCLIP Routing service has been erroneously activated even in case when call has come over the CO line without CLIP identification.
4.07rev8
• Fixed – It hasn’t be able to make a short dial from the system (key) phone using service 80xx (fw version 4.07rev6)
• Fixed error in the GSM module trace – occasionally it could be found a fake alarm message in GSM trace „Some SMSs could be lost“ even when everything was OK (fw version 4.07rev6)
4.07rev6
• Auto CLIP routing feature.
• Italian menu on key (system) phones
4.06rev25
• !!! Fixed the risk of blocking system (key) phones – in the previous versions the next call to the busy system phone could sometimes cause blocking (workaround was to disable Internal lines/Enabling of services/Whole/Action/Next call ringing) !!!
4.06rev24
• Turkish menu on key (system) phones
• Tracing of the communication to key (system) phones – needed FW 2.70, at the system phone module
• Long distance prefix activated - Example: The long distance prefix is set. e.g. „0“. New call comes from the local country. If CLIP contains the international prefix of the country, that prefix is removed (must be set in the Configuration Tool too) and replaced with the long distance prefix. The modified CLIP is sent to the phone display and could be used for call back.
4.06rev18
• Hungarian language pack.
• Support of the older GSM modul FW versions 1.01 – 2.02. Older revisions of firmware 4.06 didn’t support those versions
4.06rev15
• Change in the forwarding to external lines – If the message „call is forwarded“ isn’t enabled, an incoming call to an extension, which is forwarded to a PSTN number, will not be picked up before it would be picked up at that PSTN number. In the previous versions, message has always been enabled and billing started even before the last destination has picked that call.
• Added option in ISDN line settings: „Don’t send request for AOC“ – blocks sending of facility Invoke AOC in the ISDN setup message. The ISDN modul firmware version ISM 16.01 is needed. Configuration tool version 4.06L or higher is needed.
4.06rev13
• Fixed critical error - blocking of key phones (caused by dat.acc and dat.dia file download)
• Fixed - In the case of ringing of a few extensions, if one picked up others had missed call
• Fixed - ME enable/disable couldn't be done from the ME mobile phone
Release Notes EN
15.03.2010
!!! CAUTION !!!
Upgrade from the firmware version 4.05 or earlier to the firmware version 4.06 or higher has to be done from the configuration tool corresponding to the target firmware version i.e 4.06, 4.07 etc. When you try to upgrade it from one of older versions, it causes destruction of data in the PBX. Then, firmware has to be uploaded from the boot (service) mode. You can get to the service mode using the lower button on the left side of the PBX. For details see the manual.
!!! The correct upgrade procedure:
- make a backup of your configuration in your previous config tool
- install the newest version of the config tool (4.06, 4.07)
- do the upgrade of the firmware from the installed config tool (4.06, 4.07)
- download config from the PBX, open your stored configuration, upload it to the PBX or rewrite it manuály
4.07rev9
• Fixed: Incorrect routing of incoming calls from CO line - AutoCLIP Routing service has been erroneously activated even in case when call has come over the CO line without CLIP identification.
4.07rev8
• Fixed – It hasn’t be able to make a short dial from the system (key) phone using service 80xx (fw version 4.07rev6)
• Fixed error in the GSM module trace – occasionally it could be found a fake alarm message in GSM trace „Some SMSs could be lost“ even when everything was OK (fw version 4.07rev6)
4.07rev6
• Auto CLIP routing feature.
• Italian menu on key (system) phones
4.06rev25
• !!! Fixed the risk of blocking system (key) phones – in the previous versions the next call to the busy system phone could sometimes cause blocking (workaround was to disable Internal lines/Enabling of services/Whole/Action/Next call ringing) !!!
4.06rev24
• Turkish menu on key (system) phones
• Tracing of the communication to key (system) phones – needed FW 2.70, at the system phone module
• Long distance prefix activated - Example: The long distance prefix is set. e.g. „0“. New call comes from the local country. If CLIP contains the international prefix of the country, that prefix is removed (must be set in the Configuration Tool too) and replaced with the long distance prefix. The modified CLIP is sent to the phone display and could be used for call back.
4.06rev18
• Hungarian language pack.
• Support of the older GSM modul FW versions 1.01 – 2.02. Older revisions of firmware 4.06 didn’t support those versions
4.06rev15
• Change in the forwarding to external lines – If the message „call is forwarded“ isn’t enabled, an incoming call to an extension, which is forwarded to a PSTN number, will not be picked up before it would be picked up at that PSTN number. In the previous versions, message has always been enabled and billing started even before the last destination has picked that call.
• Added option in ISDN line settings: „Don’t send request for AOC“ – blocks sending of facility Invoke AOC in the ISDN setup message. The ISDN modul firmware version ISM 16.01 is needed. Configuration tool version 4.06L or higher is needed.
4.06rev13
• Fixed critical error - blocking of key phones (caused by dat.acc and dat.dia file download)
• Fixed - In the case of ringing of a few extensions, if one picked up others had missed call
• Fixed - ME enable/disable couldn't be done from the ME mobile phone
2N® Omega Lite / 2N® Omega 48 - Ethernet module firmware
Release Notes
21.02.2010
OLI-2-3-6 2010-02-21
• This version is displayed in web configuration interface as 2.3.6a
• !!! Fixed the critical bug – Calling from VoIP to analogue or system phone extension, that has an active voicemail, calling party could listen messages left in the called party voice mailbox. (since firmware 2.3.2)
• Xapi 2.01N
OLI-2-3-5 2009-12-23
• Backup of configuration contains only configuration folders
• Web interface – the lower left angle icons are unified in various menus
• XAPI 2.01J – fixed problem of firmware upgrade from the configuration tool, over port 1234
• PPP – significantly improved uplink data rate over UMTS module
• Web interface - improved response time
• Ring Groups - VoIP phones (extensions) could be rang together
• new default password of Admin is 2n
• DNS – fixed problem of cyclical rebooting of Ethernet module – It happened if DNS proxy was enabled and DNS servers haven’t been set
• SIP - header Diversion
• Fixed the problem with Sierra module – if RING has come during SMS sending, SMS was treated as not sent
• Voicemail – warning about almost filled up message space
OLI-2-3-2 2009-11-04
• DISA message in Ethernet module – new settings – fall to the default operator, maximal duration of the voice mail message, improved voice quality of messages
• Listen port displayed in the SIP lines menu
• H.323 – the calling party identification in incomming calls- corrected
• QoS indication could be set for RTP and SIP
• XAPI 2.01H
OLI-2-3-1 2009-09-23
• integrated XAPI server
• new, more reliable H.323 stack
• DISA - interdigit timeout, limited call duration, cycling limit
• default IP address 192.168.1.1
2N® Omega Lite / 2N® Omega 48 – Configuration Tool
Release Notes
15.03.2012
4.11A
• Opravy:
• Fixed - Volume of a GSM call didn't react according to the settings of the GSM call volume levels parameters.
4.10 E
• Data.dia and Data.acc in Windows 7 (and Vista) are saved to the Documents/User/2N TELEKOMUNIKACE/Omega Program folder.
• The ISDN module firmware version checked. I fit is 17.02 or higher an upgrade is not enabled.
4.10
• Support of the firmware 4.10rev2 (see Release Notes of 4.10rev2)
• The new Configuration Tool manual ver. 1.9
4.08 D
• Support of the firmware 4.08rev7 (see Release Notes of 4.08rev7)
• The new Configuration Tool manual ver. 1.8
4.08 C
• Support of new functions in firmware 4.08, till revision 5
• Fixed – Message „List index out of bounds“ appeared when going out of the ISDN line settings menu (sometimes, after upgrade from older firmware versions)
• The new Configuration Tool manual ver. 1.7
4.06 V, 4.07 H
• Fixed – Message „List index out of bounds“ appeared when going out of the ISDN line settings menu (sometimes, after upgrade from older firmware versions)
4.06 U, 4.07G
• !!! Fixed important error !!! – Upgrade from versions older than 4.06 could be unsuccessful. PBX has been left in the service mode.
• Fixed - new IL modules (with support of higher voltage for CLIP) haven’t displayed correctly in menu Global data/Hardware
• Info: Change in the firmware upload procedure – first are loaded language packals and after that the rest of data.
4.05 Y
• Fixed - new IL modules (with support of higher voltage for CLIP) haven’t displayed correctly in menu Global data/Hardware
4.07 D
• Auto CLIP routing – settings – separate menu
• The Italian menu on key (system) phones selection supported
• New Configuration Tool manual – version 1.6
4.06 S (service puprposes)
• Fixed problem in remote management over dialup modems – If the call from remote management modem has been manually transferred to the internal modem in Omega, the connection could be cancelled from the calling party side.
• Fixed problem – The Short Dial data from versions 4.05 and earlier couldn’t be exported to version 4.06.
Release Notes
15.03.2012
4.11A
• Opravy:
• Fixed - Volume of a GSM call didn't react according to the settings of the GSM call volume levels parameters.
4.10 E
• Data.dia and Data.acc in Windows 7 (and Vista) are saved to the Documents/User/2N TELEKOMUNIKACE/Omega Program folder.
• The ISDN module firmware version checked. I fit is 17.02 or higher an upgrade is not enabled.
4.10
• Support of the firmware 4.10rev2 (see Release Notes of 4.10rev2)
• The new Configuration Tool manual ver. 1.9
4.08 D
• Support of the firmware 4.08rev7 (see Release Notes of 4.08rev7)
• The new Configuration Tool manual ver. 1.8
4.08 C
• Support of new functions in firmware 4.08, till revision 5
• Fixed – Message „List index out of bounds“ appeared when going out of the ISDN line settings menu (sometimes, after upgrade from older firmware versions)
• The new Configuration Tool manual ver. 1.7
4.06 V, 4.07 H
• Fixed – Message „List index out of bounds“ appeared when going out of the ISDN line settings menu (sometimes, after upgrade from older firmware versions)
4.06 U, 4.07G
• !!! Fixed important error !!! – Upgrade from versions older than 4.06 could be unsuccessful. PBX has been left in the service mode.
• Fixed - new IL modules (with support of higher voltage for CLIP) haven’t displayed correctly in menu Global data/Hardware
• Info: Change in the firmware upload procedure – first are loaded language packals and after that the rest of data.
4.05 Y
• Fixed - new IL modules (with support of higher voltage for CLIP) haven’t displayed correctly in menu Global data/Hardware
4.07 D
• Auto CLIP routing – settings – separate menu
• The Italian menu on key (system) phones selection supported
• New Configuration Tool manual – version 1.6
4.06 S (service puprposes)
• Fixed problem in remote management over dialup modems – If the call from remote management modem has been manually transferred to the internal modem in Omega, the connection could be cancelled from the calling party side.
• Fixed problem – The Short Dial data from versions 4.05 and earlier couldn’t be exported to version 4.06.
2N® Omega Lite / 2N® Omega 48 – Configuration Tool
Release Notes
01.02.2011
4.10 E
• Data.dia and Data.acc in Windows 7 (and Vista) are saved to the Documents/User/2N TELEKOMUNIKACE/Omega Program folder.
• The ISDN module firmware version checked. I fit is 17.02 or higher an upgrade is not enabled.
4.10
• Support of the firmware 4.10rev2 (see Release Notes of 4.10rev2)
• The new Configuration Tool manual ver. 1.9
4.08 D
• Support of the firmware 4.08rev7 (see Release Notes of 4.08rev7)
• The new Configuration Tool manual ver. 1.8
4.08 C
• Support of new functions in firmware 4.08, till revision 5
• Fixed – Message „List index out of bounds“ appeared when going out of the ISDN line settings menu (sometimes, after upgrade from older firmware versions)
• The new Configuration Tool manual ver. 1.7
4.06 V, 4.07 H
• Fixed – Message „List index out of bounds“ appeared when going out of the ISDN line settings menu (sometimes, after upgrade from older firmware versions)
4.06 U, 4.07G
• !!! Fixed important error !!! – Upgrade from versions older than 4.06 could be unsuccessful. PBX has been left in the service mode.
• Fixed - new IL modules (with support of higher voltage for CLIP) haven’t displayed correctly in menu Global data/Hardware
• Info: Change in the firmware upload procedure – first are loaded language packals and after that the rest of data.
4.05 Y
• Fixed - new IL modules (with support of higher voltage for CLIP) haven’t displayed correctly in menu Global data/Hardware
4.07 D
• Auto CLIP routing – settings – separate menu
• The Italian menu on key (system) phones selection supported
• New Configuration Tool manual – version 1.6
4.06 S (service puprposes)
• Fixed problem in remote management over dialup modems – If the call from remote management modem has been manually transferred to the internal modem in Omega, the connection could be cancelled from the calling party side.
• Fixed problem – The Short Dial data from versions 4.05 and earlier couldn’t be exported to version 4.06.
Release Notes
01.02.2011
4.10 E
• Data.dia and Data.acc in Windows 7 (and Vista) are saved to the Documents/User/2N TELEKOMUNIKACE/Omega Program folder.
• The ISDN module firmware version checked. I fit is 17.02 or higher an upgrade is not enabled.
4.10
• Support of the firmware 4.10rev2 (see Release Notes of 4.10rev2)
• The new Configuration Tool manual ver. 1.9
4.08 D
• Support of the firmware 4.08rev7 (see Release Notes of 4.08rev7)
• The new Configuration Tool manual ver. 1.8
4.08 C
• Support of new functions in firmware 4.08, till revision 5
• Fixed – Message „List index out of bounds“ appeared when going out of the ISDN line settings menu (sometimes, after upgrade from older firmware versions)
• The new Configuration Tool manual ver. 1.7
4.06 V, 4.07 H
• Fixed – Message „List index out of bounds“ appeared when going out of the ISDN line settings menu (sometimes, after upgrade from older firmware versions)
4.06 U, 4.07G
• !!! Fixed important error !!! – Upgrade from versions older than 4.06 could be unsuccessful. PBX has been left in the service mode.
• Fixed - new IL modules (with support of higher voltage for CLIP) haven’t displayed correctly in menu Global data/Hardware
• Info: Change in the firmware upload procedure – first are loaded language packals and after that the rest of data.
4.05 Y
• Fixed - new IL modules (with support of higher voltage for CLIP) haven’t displayed correctly in menu Global data/Hardware
4.07 D
• Auto CLIP routing – settings – separate menu
• The Italian menu on key (system) phones selection supported
• New Configuration Tool manual – version 1.6
4.06 S (service puprposes)
• Fixed problem in remote management over dialup modems – If the call from remote management modem has been manually transferred to the internal modem in Omega, the connection could be cancelled from the calling party side.
• Fixed problem – The Short Dial data from versions 4.05 and earlier couldn’t be exported to version 4.06.
2N® Omega Lite / 2N® Omega 48 – Configuration Tool
Release Notes
14.09.2010
4.10
• Support of the firmware 4.10rev2 (see Release Notes of 4.10rev2)
• The new Configuration Tool manual ver. 1.9
4.08 D
• Support of the firmware 4.08rev7 (see Release Notes of 4.08rev7)
• The new Configuration Tool manual ver. 1.8
4.08 C
• Support of new functions in firmware 4.08, till revision 5
• Fixed – Message „List index out of bounds“ appeared when going out of the ISDN line settings menu (sometimes, after upgrade from older firmware versions)
• The new Configuration Tool manual ver. 1.7
4.06 V, 4.07 H
• Fixed – Message „List index out of bounds“ appeared when going out of the ISDN line settings menu (sometimes, after upgrade from older firmware versions)
4.06 U, 4.07G
• !!! Fixed important error !!! – Upgrade from versions older than 4.06 could be unsuccessful. PBX has been left in the service mode.
• Fixed - new IL modules (with support of higher voltage for CLIP) haven’t displayed correctly in menu Global data/Hardware
• Info: Change in the firmware upload procedure – first are loaded language packals and after that the rest of data.
4.05 Y
• Fixed - new IL modules (with support of higher voltage for CLIP) haven’t displayed correctly in menu Global data/Hardware
4.07 D
• Auto CLIP routing – settings – separate menu
• The Italian menu on key (system) phones selection supported
• New Configuration Tool manual – version 1.6
4.06 S (service puprposes)
• Fixed problem in remote management over dialup modems – If the call from remote management modem has been manually transferred to the internal modem in Omega, the connection could be cancelled from the calling party side.
• Fixed problem – The Short Dial data from versions 4.05 and earlier couldn’t be exported to version 4.06.
Release Notes
14.09.2010
4.10
• Support of the firmware 4.10rev2 (see Release Notes of 4.10rev2)
• The new Configuration Tool manual ver. 1.9
4.08 D
• Support of the firmware 4.08rev7 (see Release Notes of 4.08rev7)
• The new Configuration Tool manual ver. 1.8
4.08 C
• Support of new functions in firmware 4.08, till revision 5
• Fixed – Message „List index out of bounds“ appeared when going out of the ISDN line settings menu (sometimes, after upgrade from older firmware versions)
• The new Configuration Tool manual ver. 1.7
4.06 V, 4.07 H
• Fixed – Message „List index out of bounds“ appeared when going out of the ISDN line settings menu (sometimes, after upgrade from older firmware versions)
4.06 U, 4.07G
• !!! Fixed important error !!! – Upgrade from versions older than 4.06 could be unsuccessful. PBX has been left in the service mode.
• Fixed - new IL modules (with support of higher voltage for CLIP) haven’t displayed correctly in menu Global data/Hardware
• Info: Change in the firmware upload procedure – first are loaded language packals and after that the rest of data.
4.05 Y
• Fixed - new IL modules (with support of higher voltage for CLIP) haven’t displayed correctly in menu Global data/Hardware
4.07 D
• Auto CLIP routing – settings – separate menu
• The Italian menu on key (system) phones selection supported
• New Configuration Tool manual – version 1.6
4.06 S (service puprposes)
• Fixed problem in remote management over dialup modems – If the call from remote management modem has been manually transferred to the internal modem in Omega, the connection could be cancelled from the calling party side.
• Fixed problem – The Short Dial data from versions 4.05 and earlier couldn’t be exported to version 4.06.
2N® PBX Assistant O2Netcom / OMEGA Lite / OMEGA 48 – Release Notes
02.06.2010
1.03 C
• Emphasizing of Call Data Records in the History of Calls e.g calls that have been
responded to etc
• Adding notes to Call Data Records in the History of Calls
• Two sizes of the phone display window, if there has been set not to display the
whole SKIN of the phone
1.02 H
News:
• Fixed - dialing from the empty record in the call history
1.02 F
News:
• Connection to the XAPI server is automatically established when XAOI server is up.
• Setting of keys and printing of labels is available in the off-line mode too
1.02 C
News:
• Changes in short dial settings supported - related to the 2N® XAPI Server ver.
1.18D ( in the previous versions changes haven’t been accepted if the 2N® PBX Assistant was
running)
02.06.2010
1.03 C
• Emphasizing of Call Data Records in the History of Calls e.g calls that have been
responded to etc
• Adding notes to Call Data Records in the History of Calls
• Two sizes of the phone display window, if there has been set not to display the
whole SKIN of the phone
1.02 H
News:
• Fixed - dialing from the empty record in the call history
1.02 F
News:
• Connection to the XAPI server is automatically established when XAOI server is up.
• Setting of keys and printing of labels is available in the off-line mode too
1.02 C
News:
• Changes in short dial settings supported - related to the 2N® XAPI Server ver.
1.18D ( in the previous versions changes haven’t been accepted if the 2N® PBX Assistant was
running)
2N® Omega Lite / 2N® Omega 48 – Configuration Tool
Release Notes
30.05.2010
4.08 D
• Support of the firmware 4.08rev7 (see Release Notes of 4.08rev7)
• The new Configuration Tool manual ver. 1.8
4.08 C
• Support of new functions in firmware 4.08, till revision 5
• Fixed – Message „List index out of bounds“ appeared when going out of the ISDN line settings menu (sometimes, after upgrade from older firmware versions)
• The new Configuration Tool manual ver. 1.7
4.06 V, 4.07 H
• Fixed – Message „List index out of bounds“ appeared when going out of the ISDN line settings menu (sometimes, after upgrade from older firmware versions)
4.06 U, 4.07G
• !!! Fixed important error !!! – Upgrade from versions older than 4.06 could be unsuccessful. PBX has been left in the service mode.
• Fixed - new IL modules (with support of higher voltage for CLIP) haven’t displayed correctly in menu Global data/Hardware
• Info: Change in the firmware upload procedure – first are loaded language packals and after that the rest of data.
4.05 Y
• Fixed - new IL modules (with support of higher voltage for CLIP) haven’t displayed correctly in menu Global data/Hardware
4.07 D
• Auto CLIP routing – settings – separate menu
• The Italian menu on key (system) phones selection supported
• New Configuration Tool manual – version 1.6
4.06 S (service puprposes)
• Fixed problem in remote management over dialup modems – If the call from remote management modem has been manually transferred to the internal modem in Omega, the connection could be cancelled from the calling party side.
• Fixed problem – The Short Dial data from versions 4.05 and earlier couldn’t be exported to version 4.06.
Release Notes
30.05.2010
4.08 D
• Support of the firmware 4.08rev7 (see Release Notes of 4.08rev7)
• The new Configuration Tool manual ver. 1.8
4.08 C
• Support of new functions in firmware 4.08, till revision 5
• Fixed – Message „List index out of bounds“ appeared when going out of the ISDN line settings menu (sometimes, after upgrade from older firmware versions)
• The new Configuration Tool manual ver. 1.7
4.06 V, 4.07 H
• Fixed – Message „List index out of bounds“ appeared when going out of the ISDN line settings menu (sometimes, after upgrade from older firmware versions)
4.06 U, 4.07G
• !!! Fixed important error !!! – Upgrade from versions older than 4.06 could be unsuccessful. PBX has been left in the service mode.
• Fixed - new IL modules (with support of higher voltage for CLIP) haven’t displayed correctly in menu Global data/Hardware
• Info: Change in the firmware upload procedure – first are loaded language packals and after that the rest of data.
4.05 Y
• Fixed - new IL modules (with support of higher voltage for CLIP) haven’t displayed correctly in menu Global data/Hardware
4.07 D
• Auto CLIP routing – settings – separate menu
• The Italian menu on key (system) phones selection supported
• New Configuration Tool manual – version 1.6
4.06 S (service puprposes)
• Fixed problem in remote management over dialup modems – If the call from remote management modem has been manually transferred to the internal modem in Omega, the connection could be cancelled from the calling party side.
• Fixed problem – The Short Dial data from versions 4.05 and earlier couldn’t be exported to version 4.06.
2N® Omega Lite / 2N® Omega 48 – Configuration Tool
Release Notes
05.05.2010
4.08 C
• Support of new functions in firmware 4.08, till revision 5
• Fixed – Message „List index out of bounds“ appeared when going out of the ISDN line settings menu (sometimes, after upgrade from older firmware versions)
• The new Configuration Tool manual ver. 1.7
4.06 V, 4.07 H
• Fixed – Message „List index out of bounds“ appeared when going out of the ISDN line settings menu (sometimes, after upgrade from older firmware versions)
4.06 U, 4.07G
• !!! Fixed important error !!! – Upgrade from versions older than 4.06 could be unsuccessful. PBX has been left in the service mode.
• Fixed - new IL modules (with support of higher voltage for CLIP) haven’t displayed correctly in menu Global data/Hardware
• Info: Change in the firmware upload procedure – first are loaded language packals and after that the rest of data.
4.05 Y
• Fixed - new IL modules (with support of higher voltage for CLIP) haven’t displayed correctly in menu Global data/Hardware
4.07 D
• Auto CLIP routing – settings – separate menu
• The Italian menu on key (system) phones selection supported
• New Configuration Tool manual – version 1.6
4.06 S (service puprposes)
• Fixed problem in remote management over dialup modems – If the call from remote management modem has been manually transferred to the internal modem in Omega, the connection could be cancelled from the calling party side.
• Fixed problem – The Short Dial data from versions 4.05 and earlier couldn’t be exported to version 4.06.
Release Notes
05.05.2010
4.08 C
• Support of new functions in firmware 4.08, till revision 5
• Fixed – Message „List index out of bounds“ appeared when going out of the ISDN line settings menu (sometimes, after upgrade from older firmware versions)
• The new Configuration Tool manual ver. 1.7
4.06 V, 4.07 H
• Fixed – Message „List index out of bounds“ appeared when going out of the ISDN line settings menu (sometimes, after upgrade from older firmware versions)
4.06 U, 4.07G
• !!! Fixed important error !!! – Upgrade from versions older than 4.06 could be unsuccessful. PBX has been left in the service mode.
• Fixed - new IL modules (with support of higher voltage for CLIP) haven’t displayed correctly in menu Global data/Hardware
• Info: Change in the firmware upload procedure – first are loaded language packals and after that the rest of data.
4.05 Y
• Fixed - new IL modules (with support of higher voltage for CLIP) haven’t displayed correctly in menu Global data/Hardware
4.07 D
• Auto CLIP routing – settings – separate menu
• The Italian menu on key (system) phones selection supported
• New Configuration Tool manual – version 1.6
4.06 S (service puprposes)
• Fixed problem in remote management over dialup modems – If the call from remote management modem has been manually transferred to the internal modem in Omega, the connection could be cancelled from the calling party side.
• Fixed problem – The Short Dial data from versions 4.05 and earlier couldn’t be exported to version 4.06.
2N® Omega Lite / 2N® Omega 48 – Configuration Tool
Release Notes
05.05.2010
4.08 C
• Support of new functions in firmware 4.08, till revision 5
• Fixed – Message „List index out of bounds“ appeared when going out of the ISDN line settings menu (sometimes, after upgrade from older firmware versions)
• The new Configuration Tool manual ver. 1.7
4.06 V, 4.07 H
• Fixed – Message „List index out of bounds“ appeared when going out of the ISDN line settings menu (sometimes, after upgrade from older firmware versions)
4.06 U, 4.07G
• !!! Fixed important error !!! – Upgrade from versions older than 4.06 could be unsuccessful. PBX has been left in the service mode.
• Fixed - new IL modules (with support of higher voltage for CLIP) haven’t displayed correctly in menu Global data/Hardware
• Info: Change in the firmware upload procedure – first are loaded language packals and after that the rest of data.
4.05 Y
• Fixed - new IL modules (with support of higher voltage for CLIP) haven’t displayed correctly in menu Global data/Hardware
4.07 D
• Auto CLIP routing – settings – separate menu
• The Italian menu on key (system) phones selection supported
• New Configuration Tool manual – version 1.6
4.06 S (service puprposes)
• Fixed problem in remote management over dialup modems – If the call from remote management modem has been manually transferred to the internal modem in Omega, the connection could be cancelled from the calling party side.
• Fixed problem – The Short Dial data from versions 4.05 and earlier couldn’t be exported to version 4.06.
Release Notes
05.05.2010
4.08 C
• Support of new functions in firmware 4.08, till revision 5
• Fixed – Message „List index out of bounds“ appeared when going out of the ISDN line settings menu (sometimes, after upgrade from older firmware versions)
• The new Configuration Tool manual ver. 1.7
4.06 V, 4.07 H
• Fixed – Message „List index out of bounds“ appeared when going out of the ISDN line settings menu (sometimes, after upgrade from older firmware versions)
4.06 U, 4.07G
• !!! Fixed important error !!! – Upgrade from versions older than 4.06 could be unsuccessful. PBX has been left in the service mode.
• Fixed - new IL modules (with support of higher voltage for CLIP) haven’t displayed correctly in menu Global data/Hardware
• Info: Change in the firmware upload procedure – first are loaded language packals and after that the rest of data.
4.05 Y
• Fixed - new IL modules (with support of higher voltage for CLIP) haven’t displayed correctly in menu Global data/Hardware
4.07 D
• Auto CLIP routing – settings – separate menu
• The Italian menu on key (system) phones selection supported
• New Configuration Tool manual – version 1.6
4.06 S (service puprposes)
• Fixed problem in remote management over dialup modems – If the call from remote management modem has been manually transferred to the internal modem in Omega, the connection could be cancelled from the calling party side.
• Fixed problem – The Short Dial data from versions 4.05 and earlier couldn’t be exported to version 4.06.
2N® Omega Lite / 2N® Omega 48 – Configuration Tool
Release Notes
09.04.2010
4.05 Y
• Fixed - new IL modules (with support of higher voltage for CLIP) haven’t displayed correctly in menu Global data/Hardware
Release Notes
09.04.2010
4.05 Y
• Fixed - new IL modules (with support of higher voltage for CLIP) haven’t displayed correctly in menu Global data/Hardware
2N® PBX Assistant O2Netcom / OMEGA Lite / OMEGA 48 – Release Notes
1.02 H
News:
• Fixed - dialing from the empty record in the call history
1.02 F
News:
• Connection to the XAPI server is automatically established when XAOI server is up.
• Setting of keys and printing of labels is available in the off-line mode too
1.02 C
News:
• Changes in short dial settings supported - related to the 2N® XAPI Server ver. 1.18D ( in the previous versions changes haven’t been accepted if the 2N® PBX Assistant was running)
1.02 H
News:
• Fixed - dialing from the empty record in the call history
1.02 F
News:
• Connection to the XAPI server is automatically established when XAOI server is up.
• Setting of keys and printing of labels is available in the off-line mode too
1.02 C
News:
• Changes in short dial settings supported - related to the 2N® XAPI Server ver. 1.18D ( in the previous versions changes haven’t been accepted if the 2N® PBX Assistant was running)
2N® Omega Lite / 2N® Omega 48 - Ethernet module firmware
Release Notes
30.12.2011
OLI-2-3-17 2011-12-30
* SIP - FIXED - CANCEL has been ignored due to the non-matched branch parameter. Branch is not compared anymore.
OLI-2-3-16 2011-10-10
* SIP - DTMF transfer by SIP INFO method supported (set in the SIP line menu)
* Xapi 2.02H + new version of sqlite
* Improved connection establishment between external aplications and interface to the basic part of OL
* FIXED - a few issues related to the UMTS modulu settings (roaming enable/disable, DHCP server etc.)
* FIXED - doubling of the DTMF digits (during reception of SIP INFO - issue in the beta version 2.3.14)
OLI-2-3-13 2011-03-09
• The maximal numbur od concurent calls could be set in the SIP line menu
• Incoming INVITE is ignored if the source IP address doesn't match to one set in SIP Server parameter of the SIP line
• The Mobility Extension checkbox added to the Ring group settings
• Xapi 2.02F
OLI-2-3-11 2010-11-12
• Fixed – in LCR normalisation, the Caller incoming setting has been switched to Called outgoing when the record has been opened for editing e.g. to change the prefix
• The Configuration restore - by default license in the device will not be rewritten by the licence from backup
• XAPI 2.02D – Fixed - XAPI tracing couldn’t be saved to the file in the XAPI Console
OLI-2-3-10 2010-09-20
• Fixed bug – DTMF digits which has been received from the H.323 line, haven’t been sent forward
• XAPI 2.02A (see Release Notes XAPI Server ver. 1.20A)
OLI-2-3-7 2010-05-19
• Mobility Extension on SIP extensions !!! Incoming ME on SIP extensions works only if the call comes from the basic part of Omega Lite/ Omega 48 i.e. from GSM, ISDN or CO lines !!!
• Music-on-hold
• Maximal DISA length enlarged to 500kB
• CLIR service (Calling Line Identification Restriction) when calling over SIP lines (header Privacy: id)
• PPPoE – connection to Internet over ADSL modem or router in bridged mode
• Sending USSD messages over the UMTS module
• XAPI 2.01S
OLI-2-3-6 2010-02-21
• This version is displayed in web configuration interface as 2.3.6a
• !!! Fixed the critical bug – Calling from VoIP to analogue or system phone extension, that has an active voicemail, calling party could listen messages left in the called party voice mailbox. (since firmware 2.3.2)
• Xapi 2.01N
OLI-2-3-5 2009-12-23
• Backup of configuration contains only configuration folders
• Web interface – the lower left angle icons are unified in various menus
• XAPI 2.01J – fixed problem of firmware upgrade from the configuration tool, over port 1234
• PPP – significantly improved uplink data rate over UMTS module
• Web interface - improved response time
• Ring Groups - VoIP phones (extensions) could be rang together
• new default password of Admin is 2n
• DNS – fixed problem of cyclical rebooting of Ethernet module – It happened if DNS proxy was enabled and DNS servers haven’t been set
• SIP - header Diversion
• Fixed the problem with Sierra module – if RING has come during SMS sending, SMS was treated as not sent
• Voicemail – warning about almost filled up message space
OLI-2-3-2 2009-11-04
• DISA message in Ethernet module – new settings – fall to the default operator, maximal duration of the voice mail message, improved voice quality of messages
• Listen port displayed in the SIP lines menu
• H.323 – the calling party identification in incomming calls- corrected
• QoS indication could be set for RTP and SIP
• XAPI 2.01H
OLI-2-3-1 2009-09-23
• integrated XAPI server
• new, more reliable H.323 stack
• DISA - interdigit timeout, limited call duration, cycling limit
• default IP address 192.168.1.1
2N® Omega Lite / 2N® Omega 48 - Ethernet module firmware
Release Notes
10.10.2011
OLI-2-3-16 2011-10-10
* SIP - DTMF transfer by SIP INFO method supported (set in the SIP line menu)
* Xapi 2.02H + new version of sqlite
* Improved connection establishment between external aplications and interface to the basic part of OL
* FIXED - a few issues related to the UMTS modulu settings (roaming enable/disable, DHCP server etc.)
* FIXED - doubling of the DTMF digits (during reception of SIP INFO - issue in the beta version 2.3.14)
OLI-2-3-13 2011-03-09
• The maximal numbur od concurent calls could be set in the SIP line menu
• Incoming INVITE is ignored if the source IP address doesn't match to one set in SIP Server parameter of the SIP line
• The Mobility Extension checkbox added to the Ring group settings
• Xapi 2.02F
OLI-2-3-11 2010-11-12
• Fixed – in LCR normalisation, the Caller incoming setting has been switched to Called outgoing when the record has been opened for editing e.g. to change the prefix
• The Configuration restore - by default license in the device will not be rewritten by the licence from backup
• XAPI 2.02D – Fixed - XAPI tracing couldn’t be saved to the file in the XAPI Console
OLI-2-3-10 2010-09-20
• Fixed bug – DTMF digits which has been received from the H.323 line, haven’t been sent forward
• XAPI 2.02A (see Release Notes XAPI Server ver. 1.20A)
OLI-2-3-7 2010-05-19
• Mobility Extension on SIP extensions !!! Incoming ME on SIP extensions works only if the call comes from the basic part of Omega Lite/ Omega 48 i.e. from GSM, ISDN or CO lines !!!
• Music-on-hold
• Maximal DISA length enlarged to 500kB
• CLIR service (Calling Line Identification Restriction) when calling over SIP lines (header Privacy: id)
• PPPoE – connection to Internet over ADSL modem or router in bridged mode
• Sending USSD messages over the UMTS module
• XAPI 2.01S
OLI-2-3-6 2010-02-21
• This version is displayed in web configuration interface as 2.3.6a
• !!! Fixed the critical bug – Calling from VoIP to analogue or system phone extension, that has an active voicemail, calling party could listen messages left in the called party voice mailbox. (since firmware 2.3.2)
• Xapi 2.01N
OLI-2-3-5 2009-12-23
• Backup of configuration contains only configuration folders
• Web interface – the lower left angle icons are unified in various menus
• XAPI 2.01J – fixed problem of firmware upgrade from the configuration tool, over port 1234
• PPP – significantly improved uplink data rate over UMTS module
• Web interface - improved response time
• Ring Groups - VoIP phones (extensions) could be rang together
• new default password of Admin is 2n
• DNS – fixed problem of cyclical rebooting of Ethernet module – It happened if DNS proxy was enabled and DNS servers haven’t been set
• SIP - header Diversion
• Fixed the problem with Sierra module – if RING has come during SMS sending, SMS was treated as not sent
• Voicemail – warning about almost filled up message space
OLI-2-3-2 2009-11-04
• DISA message in Ethernet module – new settings – fall to the default operator, maximal duration of the voice mail message, improved voice quality of messages
• Listen port displayed in the SIP lines menu
• H.323 – the calling party identification in incomming calls- corrected
• QoS indication could be set for RTP and SIP
• XAPI 2.01H
OLI-2-3-1 2009-09-23
• integrated XAPI server
• new, more reliable H.323 stack
• DISA - interdigit timeout, limited call duration, cycling limit
• default IP address 192.168.1.1
Release Notes
10.10.2011
OLI-2-3-16 2011-10-10
* SIP - DTMF transfer by SIP INFO method supported (set in the SIP line menu)
* Xapi 2.02H + new version of sqlite
* Improved connection establishment between external aplications and interface to the basic part of OL
* FIXED - a few issues related to the UMTS modulu settings (roaming enable/disable, DHCP server etc.)
* FIXED - doubling of the DTMF digits (during reception of SIP INFO - issue in the beta version 2.3.14)
OLI-2-3-13 2011-03-09
• The maximal numbur od concurent calls could be set in the SIP line menu
• Incoming INVITE is ignored if the source IP address doesn't match to one set in SIP Server parameter of the SIP line
• The Mobility Extension checkbox added to the Ring group settings
• Xapi 2.02F
OLI-2-3-11 2010-11-12
• Fixed – in LCR normalisation, the Caller incoming setting has been switched to Called outgoing when the record has been opened for editing e.g. to change the prefix
• The Configuration restore - by default license in the device will not be rewritten by the licence from backup
• XAPI 2.02D – Fixed - XAPI tracing couldn’t be saved to the file in the XAPI Console
OLI-2-3-10 2010-09-20
• Fixed bug – DTMF digits which has been received from the H.323 line, haven’t been sent forward
• XAPI 2.02A (see Release Notes XAPI Server ver. 1.20A)
OLI-2-3-7 2010-05-19
• Mobility Extension on SIP extensions !!! Incoming ME on SIP extensions works only if the call comes from the basic part of Omega Lite/ Omega 48 i.e. from GSM, ISDN or CO lines !!!
• Music-on-hold
• Maximal DISA length enlarged to 500kB
• CLIR service (Calling Line Identification Restriction) when calling over SIP lines (header Privacy: id)
• PPPoE – connection to Internet over ADSL modem or router in bridged mode
• Sending USSD messages over the UMTS module
• XAPI 2.01S
OLI-2-3-6 2010-02-21
• This version is displayed in web configuration interface as 2.3.6a
• !!! Fixed the critical bug – Calling from VoIP to analogue or system phone extension, that has an active voicemail, calling party could listen messages left in the called party voice mailbox. (since firmware 2.3.2)
• Xapi 2.01N
OLI-2-3-5 2009-12-23
• Backup of configuration contains only configuration folders
• Web interface – the lower left angle icons are unified in various menus
• XAPI 2.01J – fixed problem of firmware upgrade from the configuration tool, over port 1234
• PPP – significantly improved uplink data rate over UMTS module
• Web interface - improved response time
• Ring Groups - VoIP phones (extensions) could be rang together
• new default password of Admin is 2n
• DNS – fixed problem of cyclical rebooting of Ethernet module – It happened if DNS proxy was enabled and DNS servers haven’t been set
• SIP - header Diversion
• Fixed the problem with Sierra module – if RING has come during SMS sending, SMS was treated as not sent
• Voicemail – warning about almost filled up message space
OLI-2-3-2 2009-11-04
• DISA message in Ethernet module – new settings – fall to the default operator, maximal duration of the voice mail message, improved voice quality of messages
• Listen port displayed in the SIP lines menu
• H.323 – the calling party identification in incomming calls- corrected
• QoS indication could be set for RTP and SIP
• XAPI 2.01H
OLI-2-3-1 2009-09-23
• integrated XAPI server
• new, more reliable H.323 stack
• DISA - interdigit timeout, limited call duration, cycling limit
• default IP address 192.168.1.1
2N® Omega Lite/ 2N® Omega 48 – Firmware
Release Notes EN
01.02.2011
!!! WARNING !!!
Upgrade from the firmware version 4.05 or earlier to the firmware version 4.06 or higher has to be done from the configuration tool corresponding to the target firmware version i.e 4.06, 4.07 etc. When you try to upgrade it from one of older versions, it causes destruction of data in the PBX. Then, firmware has to be uploaded from the boot (service) mode. You can get to the service mode using the lower button on the left side of the PBX. For details see the manual.
!!! The correct upgrade procedure:
- make a backup of your configuration in your original config tool e.g. 4.05
- install the newest version of the config tool (4.06, 4.07, 4.08)
- do the upgrade of the firmware from the installed config tool (4.06, 4.07, 4.08)
- download config from the PBX in new config tool
- open your stored configuration in the originál config tool and rewrite it manualy to the new config tool
- upload configuration from the new config tool to PBX
4.10rev6
• !!! Fixed the bug in previous revisions - key phones stayed in the blocked status, PBX reset has been needed !!! The key phone module firmware upgrade to version 2.80 needed !!!
• Settings of 2N OpenStage key phone and PBX are paired
4.08rev10
• Searching in phone directory on system (key) phones using up to 3 leading characters. After that, it is possible to scroll the whole directory using < and > buttons.
• !!! Fixed the bug in previous revisions - If the call has come from UMTS or VoIP without the calling party identification, it has been proceeded according to the last call in the Auto CLIP Routing table. Now it is proceeded according to the relevant ringing table.
4.08rev8
• !!! Fixed the bug in previous revisions - Called numbes have been incorrectly presented in the list of called numbers on the key phone (some of them missed last digits and the last number had an additional 0 at the end). This bug could cause incorrect behaviour of AutoCLIP Routing.
4.08rev7
• !!! Fixed the bug in 4.08rev5 - If the cumulative length of all Text fields (name of the Short dial) is longer than 20 characters, following records couldn’t be saved correctly. This bug influented correct behaviour of the Event report SMSs too. If you have such configuration of the Short dials table, use this revision (or later) if doing upgrade to version 4.08! Use the configuration tool version 4.08D!
• !!! WARNING !!! Save the PBX configuration before upgrade to FW 4.08rev7. This upgrade automatically does the factory reset!!!
4.08rev5
• SMS Event reporting - info about: settings ganges, link failure, the SIM card credit, switch status etc.)
• Binary switch actions - send user SMS, block phones, block external lines, day/night switching, close contact relay).
• CLIR function - select if call would be made with identification or not. Could be associated to the key on the key phone. LED diode next to the key shines if CLIR is aktive.
• Fixed: DTMF sometimes not sent correctly from key phone to ISDN line
• Auto CLIP Routing enable/disable for each internal line separatelly (Internal lines/Enabling of services)
4.07rev9
• Fixed: Incorrect routing of incoming calls from CO line - AutoCLIP Routing service has been erroneously activated even in case when call has come over the CO line without CLIP identification.
4.07rev8
• Fixed – It hasn’t be able to make a short dial from the system (key) phone using service 80xx (fw version 4.07rev6)
• Fixed error in the GSM module trace – occasionally it could be found a fake alarm message in GSM trace „Some SMSs could be lost“ even when everything was OK (fw version 4.07rev6)
4.07rev6
• Auto CLIP routing feature.
• Italian menu on key (system) phones
4.06rev25
• !!! Fixed the risk of blocking system (key) phones – in the previous versions the next call to the busy system phone could sometimes cause blocking (workaround was to disable Internal lines/Enabling of services/Whole/Action/Next call ringing) !!!
4.06rev24
• Turkish menu on key (system) phones
• Tracing of the communication to key (system) phones – needed FW 2.70, at the system phone module
• Long distance prefix activated - Example: The long distance prefix is set. e.g. „0“. New call comes from the local country. If CLIP contains the international prefix of the country, that prefix is removed (must be set in the Configuration Tool too) and replaced with the long distance prefix. The modified CLIP is sent to the phone display and could be used for call back.
4.06rev18
• Hungarian language pack.
• Support of the older GSM modul FW versions 1.01 – 2.02. Older revisions of firmware 4.06 didn’t support those versions
4.06rev15
• Change in the forwarding to external lines – If the message „call is forwarded“ isn’t enabled, an incoming call to an extension, which is forwarded to a PSTN number, will not be picked up before it would be picked up at that PSTN number. In the previous versions, message has always been enabled and billing started even before the last destination has picked that call.
• Added option in ISDN line settings: „Don’t send request for AOC“ – blocks sending of facility Invoke AOC in the ISDN setup message. The ISDN modul firmware version ISM 16.01 is needed. Configuration tool version 4.06L or higher is needed.
4.06rev13
• Fixed critical error - blocking of key phones (caused by dat.acc and dat.dia file download)
• Fixed - In the case of ringing of a few extensions, if one picked up others had missed call
• Fixed - ME enable/disable couldn't be done from the ME mobile phone
Release Notes EN
01.02.2011
!!! WARNING !!!
Upgrade from the firmware version 4.05 or earlier to the firmware version 4.06 or higher has to be done from the configuration tool corresponding to the target firmware version i.e 4.06, 4.07 etc. When you try to upgrade it from one of older versions, it causes destruction of data in the PBX. Then, firmware has to be uploaded from the boot (service) mode. You can get to the service mode using the lower button on the left side of the PBX. For details see the manual.
!!! The correct upgrade procedure:
- make a backup of your configuration in your original config tool e.g. 4.05
- install the newest version of the config tool (4.06, 4.07, 4.08)
- do the upgrade of the firmware from the installed config tool (4.06, 4.07, 4.08)
- download config from the PBX in new config tool
- open your stored configuration in the originál config tool and rewrite it manualy to the new config tool
- upload configuration from the new config tool to PBX
4.10rev6
• !!! Fixed the bug in previous revisions - key phones stayed in the blocked status, PBX reset has been needed !!! The key phone module firmware upgrade to version 2.80 needed !!!
• Settings of 2N OpenStage key phone and PBX are paired
4.08rev10
• Searching in phone directory on system (key) phones using up to 3 leading characters. After that, it is possible to scroll the whole directory using < and > buttons.
• !!! Fixed the bug in previous revisions - If the call has come from UMTS or VoIP without the calling party identification, it has been proceeded according to the last call in the Auto CLIP Routing table. Now it is proceeded according to the relevant ringing table.
4.08rev8
• !!! Fixed the bug in previous revisions - Called numbes have been incorrectly presented in the list of called numbers on the key phone (some of them missed last digits and the last number had an additional 0 at the end). This bug could cause incorrect behaviour of AutoCLIP Routing.
4.08rev7
• !!! Fixed the bug in 4.08rev5 - If the cumulative length of all Text fields (name of the Short dial) is longer than 20 characters, following records couldn’t be saved correctly. This bug influented correct behaviour of the Event report SMSs too. If you have such configuration of the Short dials table, use this revision (or later) if doing upgrade to version 4.08! Use the configuration tool version 4.08D!
• !!! WARNING !!! Save the PBX configuration before upgrade to FW 4.08rev7. This upgrade automatically does the factory reset!!!
4.08rev5
• SMS Event reporting - info about: settings ganges, link failure, the SIM card credit, switch status etc.)
• Binary switch actions - send user SMS, block phones, block external lines, day/night switching, close contact relay).
• CLIR function - select if call would be made with identification or not. Could be associated to the key on the key phone. LED diode next to the key shines if CLIR is aktive.
• Fixed: DTMF sometimes not sent correctly from key phone to ISDN line
• Auto CLIP Routing enable/disable for each internal line separatelly (Internal lines/Enabling of services)
4.07rev9
• Fixed: Incorrect routing of incoming calls from CO line - AutoCLIP Routing service has been erroneously activated even in case when call has come over the CO line without CLIP identification.
4.07rev8
• Fixed – It hasn’t be able to make a short dial from the system (key) phone using service 80xx (fw version 4.07rev6)
• Fixed error in the GSM module trace – occasionally it could be found a fake alarm message in GSM trace „Some SMSs could be lost“ even when everything was OK (fw version 4.07rev6)
4.07rev6
• Auto CLIP routing feature.
• Italian menu on key (system) phones
4.06rev25
• !!! Fixed the risk of blocking system (key) phones – in the previous versions the next call to the busy system phone could sometimes cause blocking (workaround was to disable Internal lines/Enabling of services/Whole/Action/Next call ringing) !!!
4.06rev24
• Turkish menu on key (system) phones
• Tracing of the communication to key (system) phones – needed FW 2.70, at the system phone module
• Long distance prefix activated - Example: The long distance prefix is set. e.g. „0“. New call comes from the local country. If CLIP contains the international prefix of the country, that prefix is removed (must be set in the Configuration Tool too) and replaced with the long distance prefix. The modified CLIP is sent to the phone display and could be used for call back.
4.06rev18
• Hungarian language pack.
• Support of the older GSM modul FW versions 1.01 – 2.02. Older revisions of firmware 4.06 didn’t support those versions
4.06rev15
• Change in the forwarding to external lines – If the message „call is forwarded“ isn’t enabled, an incoming call to an extension, which is forwarded to a PSTN number, will not be picked up before it would be picked up at that PSTN number. In the previous versions, message has always been enabled and billing started even before the last destination has picked that call.
• Added option in ISDN line settings: „Don’t send request for AOC“ – blocks sending of facility Invoke AOC in the ISDN setup message. The ISDN modul firmware version ISM 16.01 is needed. Configuration tool version 4.06L or higher is needed.
4.06rev13
• Fixed critical error - blocking of key phones (caused by dat.acc and dat.dia file download)
• Fixed - In the case of ringing of a few extensions, if one picked up others had missed call
• Fixed - ME enable/disable couldn't be done from the ME mobile phone
2N® Omega Lite/ 2N® Omega 48 – Firmware
Release Notes EN
01.02.2011
!!! WARNING !!!
Upgrade from the firmware version 4.05 or earlier to the firmware version 4.06 or higher has to be done from the configuration tool corresponding to the target firmware version i.e 4.06, 4.07 etc. When you try to upgrade it from one of older versions, it causes destruction of data in the PBX. Then, firmware has to be uploaded from the boot (service) mode. You can get to the service mode using the lower button on the left side of the PBX. For details see the manual.
!!! The correct upgrade procedure:
- make a backup of your configuration in your original config tool e.g. 4.05
- install the newest version of the config tool (4.06, 4.07, 4.08)
- do the upgrade of the firmware from the installed config tool (4.06, 4.07, 4.08)
- download config from the PBX in new config tool
- open your stored configuration in the originál config tool and rewrite it manualy to the new config tool
- upload configuration from the new config tool to PBX
4.10rev6
• !!! Fixed the bug in previous revisions - key phones stayed in the blocked status, PBX reset has been needed !!! The key phone module firmware upgrade to version 2.80 needed !!!
• Settings of 2N OpenStage key phone and PBX are paired
4.08rev10
• Searching in phone directory on system (key) phones using up to 3 leading characters. After that, it is possible to scroll the whole directory using < and > buttons.
• !!! Fixed the bug in previous revisions - If the call has come from UMTS or VoIP without the calling party identification, it has been proceeded according to the last call in the Auto CLIP Routing table. Now it is proceeded according to the relevant ringing table.
4.08rev8
• !!! Fixed the bug in previous revisions - Called numbes have been incorrectly presented in the list of called numbers on the key phone (some of them missed last digits and the last number had an additional 0 at the end). This bug could cause incorrect behaviour of AutoCLIP Routing.
4.08rev7
• !!! Fixed the bug in 4.08rev5 - If the cumulative length of all Text fields (name of the Short dial) is longer than 20 characters, following records couldn’t be saved correctly. This bug influented correct behaviour of the Event report SMSs too. If you have such configuration of the Short dials table, use this revision (or later) if doing upgrade to version 4.08! Use the configuration tool version 4.08D!
• !!! WARNING !!! Save the PBX configuration before upgrade to FW 4.08rev7. This upgrade automatically does the factory reset!!!
4.08rev5
• SMS Event reporting - info about: settings ganges, link failure, the SIM card credit, switch status etc.)
• Binary switch actions - send user SMS, block phones, block external lines, day/night switching, close contact relay).
• CLIR function - select if call would be made with identification or not. Could be associated to the key on the key phone. LED diode next to the key shines if CLIR is aktive.
• Fixed: DTMF sometimes not sent correctly from key phone to ISDN line
• Auto CLIP Routing enable/disable for each internal line separatelly (Internal lines/Enabling of services)
4.07rev9
• Fixed: Incorrect routing of incoming calls from CO line - AutoCLIP Routing service has been erroneously activated even in case when call has come over the CO line without CLIP identification.
4.07rev8
• Fixed – It hasn’t be able to make a short dial from the system (key) phone using service 80xx (fw version 4.07rev6)
• Fixed error in the GSM module trace – occasionally it could be found a fake alarm message in GSM trace „Some SMSs could be lost“ even when everything was OK (fw version 4.07rev6)
4.07rev6
• Auto CLIP routing feature.
• Italian menu on key (system) phones
4.06rev25
• !!! Fixed the risk of blocking system (key) phones – in the previous versions the next call to the busy system phone could sometimes cause blocking (workaround was to disable Internal lines/Enabling of services/Whole/Action/Next call ringing) !!!
4.06rev24
• Turkish menu on key (system) phones
• Tracing of the communication to key (system) phones – needed FW 2.70, at the system phone module
• Long distance prefix activated - Example: The long distance prefix is set. e.g. „0“. New call comes from the local country. If CLIP contains the international prefix of the country, that prefix is removed (must be set in the Configuration Tool too) and replaced with the long distance prefix. The modified CLIP is sent to the phone display and could be used for call back.
4.06rev18
• Hungarian language pack.
• Support of the older GSM modul FW versions 1.01 – 2.02. Older revisions of firmware 4.06 didn’t support those versions
4.06rev15
• Change in the forwarding to external lines – If the message „call is forwarded“ isn’t enabled, an incoming call to an extension, which is forwarded to a PSTN number, will not be picked up before it would be picked up at that PSTN number. In the previous versions, message has always been enabled and billing started even before the last destination has picked that call.
• Added option in ISDN line settings: „Don’t send request for AOC“ – blocks sending of facility Invoke AOC in the ISDN setup message. The ISDN modul firmware version ISM 16.01 is needed. Configuration tool version 4.06L or higher is needed.
4.06rev13
• Fixed critical error - blocking of key phones (caused by dat.acc and dat.dia file download)
• Fixed - In the case of ringing of a few extensions, if one picked up others had missed call
• Fixed - ME enable/disable couldn't be done from the ME mobile phone
Release Notes EN
01.02.2011
!!! WARNING !!!
Upgrade from the firmware version 4.05 or earlier to the firmware version 4.06 or higher has to be done from the configuration tool corresponding to the target firmware version i.e 4.06, 4.07 etc. When you try to upgrade it from one of older versions, it causes destruction of data in the PBX. Then, firmware has to be uploaded from the boot (service) mode. You can get to the service mode using the lower button on the left side of the PBX. For details see the manual.
!!! The correct upgrade procedure:
- make a backup of your configuration in your original config tool e.g. 4.05
- install the newest version of the config tool (4.06, 4.07, 4.08)
- do the upgrade of the firmware from the installed config tool (4.06, 4.07, 4.08)
- download config from the PBX in new config tool
- open your stored configuration in the originál config tool and rewrite it manualy to the new config tool
- upload configuration from the new config tool to PBX
4.10rev6
• !!! Fixed the bug in previous revisions - key phones stayed in the blocked status, PBX reset has been needed !!! The key phone module firmware upgrade to version 2.80 needed !!!
• Settings of 2N OpenStage key phone and PBX are paired
4.08rev10
• Searching in phone directory on system (key) phones using up to 3 leading characters. After that, it is possible to scroll the whole directory using < and > buttons.
• !!! Fixed the bug in previous revisions - If the call has come from UMTS or VoIP without the calling party identification, it has been proceeded according to the last call in the Auto CLIP Routing table. Now it is proceeded according to the relevant ringing table.
4.08rev8
• !!! Fixed the bug in previous revisions - Called numbes have been incorrectly presented in the list of called numbers on the key phone (some of them missed last digits and the last number had an additional 0 at the end). This bug could cause incorrect behaviour of AutoCLIP Routing.
4.08rev7
• !!! Fixed the bug in 4.08rev5 - If the cumulative length of all Text fields (name of the Short dial) is longer than 20 characters, following records couldn’t be saved correctly. This bug influented correct behaviour of the Event report SMSs too. If you have such configuration of the Short dials table, use this revision (or later) if doing upgrade to version 4.08! Use the configuration tool version 4.08D!
• !!! WARNING !!! Save the PBX configuration before upgrade to FW 4.08rev7. This upgrade automatically does the factory reset!!!
4.08rev5
• SMS Event reporting - info about: settings ganges, link failure, the SIM card credit, switch status etc.)
• Binary switch actions - send user SMS, block phones, block external lines, day/night switching, close contact relay).
• CLIR function - select if call would be made with identification or not. Could be associated to the key on the key phone. LED diode next to the key shines if CLIR is aktive.
• Fixed: DTMF sometimes not sent correctly from key phone to ISDN line
• Auto CLIP Routing enable/disable for each internal line separatelly (Internal lines/Enabling of services)
4.07rev9
• Fixed: Incorrect routing of incoming calls from CO line - AutoCLIP Routing service has been erroneously activated even in case when call has come over the CO line without CLIP identification.
4.07rev8
• Fixed – It hasn’t be able to make a short dial from the system (key) phone using service 80xx (fw version 4.07rev6)
• Fixed error in the GSM module trace – occasionally it could be found a fake alarm message in GSM trace „Some SMSs could be lost“ even when everything was OK (fw version 4.07rev6)
4.07rev6
• Auto CLIP routing feature.
• Italian menu on key (system) phones
4.06rev25
• !!! Fixed the risk of blocking system (key) phones – in the previous versions the next call to the busy system phone could sometimes cause blocking (workaround was to disable Internal lines/Enabling of services/Whole/Action/Next call ringing) !!!
4.06rev24
• Turkish menu on key (system) phones
• Tracing of the communication to key (system) phones – needed FW 2.70, at the system phone module
• Long distance prefix activated - Example: The long distance prefix is set. e.g. „0“. New call comes from the local country. If CLIP contains the international prefix of the country, that prefix is removed (must be set in the Configuration Tool too) and replaced with the long distance prefix. The modified CLIP is sent to the phone display and could be used for call back.
4.06rev18
• Hungarian language pack.
• Support of the older GSM modul FW versions 1.01 – 2.02. Older revisions of firmware 4.06 didn’t support those versions
4.06rev15
• Change in the forwarding to external lines – If the message „call is forwarded“ isn’t enabled, an incoming call to an extension, which is forwarded to a PSTN number, will not be picked up before it would be picked up at that PSTN number. In the previous versions, message has always been enabled and billing started even before the last destination has picked that call.
• Added option in ISDN line settings: „Don’t send request for AOC“ – blocks sending of facility Invoke AOC in the ISDN setup message. The ISDN modul firmware version ISM 16.01 is needed. Configuration tool version 4.06L or higher is needed.
4.06rev13
• Fixed critical error - blocking of key phones (caused by dat.acc and dat.dia file download)
• Fixed - In the case of ringing of a few extensions, if one picked up others had missed call
• Fixed - ME enable/disable couldn't be done from the ME mobile phone
2N® Omega Lite/ 2N® Omega 48 – Firmware
Release Notes EN
26.07.2010
!!! WARNING !!!
Upgrade from the firmware version 4.05 or earlier to the firmware version 4.06 or higher has to be done from the configuration tool corresponding to the target firmware version i.e 4.06, 4.07 etc. When you try to upgrade it from one of older versions, it causes destruction of data in the PBX. Then, firmware has to be uploaded from the boot (service) mode. You can get to the service mode using the lower button on the left side of the PBX. For details see the manual.
!!! The correct upgrade procedure:
- make a backup of your configuration in your original config tool e.g. 4.05
- install the newest version of the config tool (4.06, 4.07, 4.08)
- do the upgrade of the firmware from the installed config tool (4.06, 4.07, 4.08)
- download config from the PBX in new config tool
- open your stored configuration in the originál config tool and rewrite it manualy to the new config tool
- upload configuration from the new config tool to PBX
4.08rev10
• Searching in phone directory on system (key) phones using up to 3 leading characters. After that, it is possible to scroll the whole directory using < and > buttons.
• !!! Fixed the bug in previous revisions - If the call has come from UMTS or VoIP without the calling party identification, it has been proceeded according to the last call in the Auto CLIP Routing table. Now it is proceeded according to the relevant ringing table.
4.08rev8
• !!! Fixed the bug in previous revisions - Called numbes have been incorrectly presented in the list of called numbers on the key phone (some of them missed last digits and the last number had an additional 0 at the end). This bug could cause incorrect behaviour of AutoCLIP Routing.
4.08rev7
• !!! Fixed the bug in 4.08rev5 - If the cumulative length of all Text fields (name of the Short dial) is longer than 20 characters, following records couldn’t be saved correctly. This bug influented correct behaviour of the Event report SMSs too. If you have such configuration of the Short dials table, use this revision (or later) if doing upgrade to version 4.08! Use the configuration tool version 4.08D!
• !!! WARNING !!! Save the PBX configuration before upgrade to FW 4.08rev7. This upgrade automatically does the factory reset!!!
4.08rev5
• SMS Event reporting - info about: settings ganges, link failure, the SIM card credit, switch status etc.)
• Binary switch actions - send user SMS, block phones, block external lines, day/night switching, close contact relay).
• CLIR function - select if call would be made with identification or not. Could be associated to the key on the key phone. LED diode next to the key shines if CLIR is aktive.
• Fixed: DTMF sometimes not sent correctly from key phone to ISDN line
• Auto CLIP Routing enable/disable for each internal line separatelly (Internal lines/Enabling of services)
4.07rev9
• Fixed: Incorrect routing of incoming calls from CO line - AutoCLIP Routing service has been erroneously activated even in case when call has come over the CO line without CLIP identification.
4.07rev8
• Fixed – It hasn’t be able to make a short dial from the system (key) phone using service 80xx (fw version 4.07rev6)
• Fixed error in the GSM module trace – occasionally it could be found a fake alarm message in GSM trace „Some SMSs could be lost“ even when everything was OK (fw version 4.07rev6)
4.07rev6
• Auto CLIP routing feature.
• Italian menu on key (system) phones
4.06rev25
• !!! Fixed the risk of blocking system (key) phones – in the previous versions the next call to the busy system phone could sometimes cause blocking (workaround was to disable Internal lines/Enabling of services/Whole/Action/Next call ringing) !!!
4.06rev24
• Turkish menu on key (system) phones
• Tracing of the communication to key (system) phones – needed FW 2.70, at the system phone module
• Long distance prefix activated - Example: The long distance prefix is set. e.g. „0“. New call comes from the local country. If CLIP contains the international prefix of the country, that prefix is removed (must be set in the Configuration Tool too) and replaced with the long distance prefix. The modified CLIP is sent to the phone display and could be used for call back.
4.06rev18
• Hungarian language pack.
• Support of the older GSM modul FW versions 1.01 – 2.02. Older revisions of firmware 4.06 didn’t support those versions
4.06rev15
• Change in the forwarding to external lines – If the message „call is forwarded“ isn’t enabled, an incoming call to an extension, which is forwarded to a PSTN number, will not be picked up before it would be picked up at that PSTN number. In the previous versions, message has always been enabled and billing started even before the last destination has picked that call.
• Added option in ISDN line settings: „Don’t send request for AOC“ – blocks sending of facility Invoke AOC in the ISDN setup message. The ISDN modul firmware version ISM 16.01 is needed. Configuration tool version 4.06L or higher is needed.
4.06rev13
• Fixed critical error - blocking of key phones (caused by dat.acc and dat.dia file download)
• Fixed - In the case of ringing of a few extensions, if one picked up others had missed call
• Fixed - ME enable/disable couldn't be done from the ME mobile phone
Release Notes EN
26.07.2010
!!! WARNING !!!
Upgrade from the firmware version 4.05 or earlier to the firmware version 4.06 or higher has to be done from the configuration tool corresponding to the target firmware version i.e 4.06, 4.07 etc. When you try to upgrade it from one of older versions, it causes destruction of data in the PBX. Then, firmware has to be uploaded from the boot (service) mode. You can get to the service mode using the lower button on the left side of the PBX. For details see the manual.
!!! The correct upgrade procedure:
- make a backup of your configuration in your original config tool e.g. 4.05
- install the newest version of the config tool (4.06, 4.07, 4.08)
- do the upgrade of the firmware from the installed config tool (4.06, 4.07, 4.08)
- download config from the PBX in new config tool
- open your stored configuration in the originál config tool and rewrite it manualy to the new config tool
- upload configuration from the new config tool to PBX
4.08rev10
• Searching in phone directory on system (key) phones using up to 3 leading characters. After that, it is possible to scroll the whole directory using < and > buttons.
• !!! Fixed the bug in previous revisions - If the call has come from UMTS or VoIP without the calling party identification, it has been proceeded according to the last call in the Auto CLIP Routing table. Now it is proceeded according to the relevant ringing table.
4.08rev8
• !!! Fixed the bug in previous revisions - Called numbes have been incorrectly presented in the list of called numbers on the key phone (some of them missed last digits and the last number had an additional 0 at the end). This bug could cause incorrect behaviour of AutoCLIP Routing.
4.08rev7
• !!! Fixed the bug in 4.08rev5 - If the cumulative length of all Text fields (name of the Short dial) is longer than 20 characters, following records couldn’t be saved correctly. This bug influented correct behaviour of the Event report SMSs too. If you have such configuration of the Short dials table, use this revision (or later) if doing upgrade to version 4.08! Use the configuration tool version 4.08D!
• !!! WARNING !!! Save the PBX configuration before upgrade to FW 4.08rev7. This upgrade automatically does the factory reset!!!
4.08rev5
• SMS Event reporting - info about: settings ganges, link failure, the SIM card credit, switch status etc.)
• Binary switch actions - send user SMS, block phones, block external lines, day/night switching, close contact relay).
• CLIR function - select if call would be made with identification or not. Could be associated to the key on the key phone. LED diode next to the key shines if CLIR is aktive.
• Fixed: DTMF sometimes not sent correctly from key phone to ISDN line
• Auto CLIP Routing enable/disable for each internal line separatelly (Internal lines/Enabling of services)
4.07rev9
• Fixed: Incorrect routing of incoming calls from CO line - AutoCLIP Routing service has been erroneously activated even in case when call has come over the CO line without CLIP identification.
4.07rev8
• Fixed – It hasn’t be able to make a short dial from the system (key) phone using service 80xx (fw version 4.07rev6)
• Fixed error in the GSM module trace – occasionally it could be found a fake alarm message in GSM trace „Some SMSs could be lost“ even when everything was OK (fw version 4.07rev6)
4.07rev6
• Auto CLIP routing feature.
• Italian menu on key (system) phones
4.06rev25
• !!! Fixed the risk of blocking system (key) phones – in the previous versions the next call to the busy system phone could sometimes cause blocking (workaround was to disable Internal lines/Enabling of services/Whole/Action/Next call ringing) !!!
4.06rev24
• Turkish menu on key (system) phones
• Tracing of the communication to key (system) phones – needed FW 2.70, at the system phone module
• Long distance prefix activated - Example: The long distance prefix is set. e.g. „0“. New call comes from the local country. If CLIP contains the international prefix of the country, that prefix is removed (must be set in the Configuration Tool too) and replaced with the long distance prefix. The modified CLIP is sent to the phone display and could be used for call back.
4.06rev18
• Hungarian language pack.
• Support of the older GSM modul FW versions 1.01 – 2.02. Older revisions of firmware 4.06 didn’t support those versions
4.06rev15
• Change in the forwarding to external lines – If the message „call is forwarded“ isn’t enabled, an incoming call to an extension, which is forwarded to a PSTN number, will not be picked up before it would be picked up at that PSTN number. In the previous versions, message has always been enabled and billing started even before the last destination has picked that call.
• Added option in ISDN line settings: „Don’t send request for AOC“ – blocks sending of facility Invoke AOC in the ISDN setup message. The ISDN modul firmware version ISM 16.01 is needed. Configuration tool version 4.06L or higher is needed.
4.06rev13
• Fixed critical error - blocking of key phones (caused by dat.acc and dat.dia file download)
• Fixed - In the case of ringing of a few extensions, if one picked up others had missed call
• Fixed - ME enable/disable couldn't be done from the ME mobile phone
2N® Omega Lite/ 2N® Omega 48 – Firmware
Release Notes EN
26.07.2010
!!! WARNING !!!
Upgrade from the firmware version 4.05 or earlier to the firmware version 4.06 or higher has to be done from the configuration tool corresponding to the target firmware version i.e 4.06, 4.07 etc. When you try to upgrade it from one of older versions, it causes destruction of data in the PBX. Then, firmware has to be uploaded from the boot (service) mode. You can get to the service mode using the lower button on the left side of the PBX. For details see the manual.
!!! The correct upgrade procedure:
- make a backup of your configuration in your original config tool e.g. 4.05
- install the newest version of the config tool (4.06, 4.07, 4.08)
- do the upgrade of the firmware from the installed config tool (4.06, 4.07, 4.08)
- download config from the PBX in new config tool
- open your stored configuration in the originál config tool and rewrite it manualy to the new config tool
- upload configuration from the new config tool to PBX
4.08rev10
• Searching in phone directory on system (key) phones using up to 3 leading characters. After that, it is possible to scroll the whole directory using < and > buttons.
• !!! Fixed the bug in previous revisions - If the call has come from UMTS or VoIP without the calling party identification, it has been proceeded according to the last call in the Auto CLIP Routing table. Now it is proceeded according to the relevant ringing table.
4.08rev8
• !!! Fixed the bug in previous revisions - Called numbes have been incorrectly presented in the list of called numbers on the key phone (some of them missed last digits and the last number had an additional 0 at the end). This bug could cause incorrect behaviour of AutoCLIP Routing.
4.08rev7
• !!! Fixed the bug in 4.08rev5 - If the cumulative length of all Text fields (name of the Short dial) is longer than 20 characters, following records couldn’t be saved correctly. This bug influented correct behaviour of the Event report SMSs too. If you have such configuration of the Short dials table, use this revision (or later) if doing upgrade to version 4.08! Use the configuration tool version 4.08D!
• !!! WARNING !!! Save the PBX configuration before upgrade to FW 4.08rev7. This upgrade automatically does the factory reset!!!
4.08rev5
• SMS Event reporting - info about: settings ganges, link failure, the SIM card credit, switch status etc.)
• Binary switch actions - send user SMS, block phones, block external lines, day/night switching, close contact relay).
• CLIR function - select if call would be made with identification or not. Could be associated to the key on the key phone. LED diode next to the key shines if CLIR is aktive.
• Fixed: DTMF sometimes not sent correctly from key phone to ISDN line
• Auto CLIP Routing enable/disable for each internal line separatelly (Internal lines/Enabling of services)
4.07rev9
• Fixed: Incorrect routing of incoming calls from CO line - AutoCLIP Routing service has been erroneously activated even in case when call has come over the CO line without CLIP identification.
4.07rev8
• Fixed – It hasn’t be able to make a short dial from the system (key) phone using service 80xx (fw version 4.07rev6)
• Fixed error in the GSM module trace – occasionally it could be found a fake alarm message in GSM trace „Some SMSs could be lost“ even when everything was OK (fw version 4.07rev6)
4.07rev6
• Auto CLIP routing feature.
• Italian menu on key (system) phones
4.06rev25
• !!! Fixed the risk of blocking system (key) phones – in the previous versions the next call to the busy system phone could sometimes cause blocking (workaround was to disable Internal lines/Enabling of services/Whole/Action/Next call ringing) !!!
4.06rev24
• Turkish menu on key (system) phones
• Tracing of the communication to key (system) phones – needed FW 2.70, at the system phone module
• Long distance prefix activated - Example: The long distance prefix is set. e.g. „0“. New call comes from the local country. If CLIP contains the international prefix of the country, that prefix is removed (must be set in the Configuration Tool too) and replaced with the long distance prefix. The modified CLIP is sent to the phone display and could be used for call back.
4.06rev18
• Hungarian language pack.
• Support of the older GSM modul FW versions 1.01 – 2.02. Older revisions of firmware 4.06 didn’t support those versions
4.06rev15
• Change in the forwarding to external lines – If the message „call is forwarded“ isn’t enabled, an incoming call to an extension, which is forwarded to a PSTN number, will not be picked up before it would be picked up at that PSTN number. In the previous versions, message has always been enabled and billing started even before the last destination has picked that call.
• Added option in ISDN line settings: „Don’t send request for AOC“ – blocks sending of facility Invoke AOC in the ISDN setup message. The ISDN modul firmware version ISM 16.01 is needed. Configuration tool version 4.06L or higher is needed.
4.06rev13
• Fixed critical error - blocking of key phones (caused by dat.acc and dat.dia file download)
• Fixed - In the case of ringing of a few extensions, if one picked up others had missed call
• Fixed - ME enable/disable couldn't be done from the ME mobile phone
Release Notes EN
26.07.2010
!!! WARNING !!!
Upgrade from the firmware version 4.05 or earlier to the firmware version 4.06 or higher has to be done from the configuration tool corresponding to the target firmware version i.e 4.06, 4.07 etc. When you try to upgrade it from one of older versions, it causes destruction of data in the PBX. Then, firmware has to be uploaded from the boot (service) mode. You can get to the service mode using the lower button on the left side of the PBX. For details see the manual.
!!! The correct upgrade procedure:
- make a backup of your configuration in your original config tool e.g. 4.05
- install the newest version of the config tool (4.06, 4.07, 4.08)
- do the upgrade of the firmware from the installed config tool (4.06, 4.07, 4.08)
- download config from the PBX in new config tool
- open your stored configuration in the originál config tool and rewrite it manualy to the new config tool
- upload configuration from the new config tool to PBX
4.08rev10
• Searching in phone directory on system (key) phones using up to 3 leading characters. After that, it is possible to scroll the whole directory using < and > buttons.
• !!! Fixed the bug in previous revisions - If the call has come from UMTS or VoIP without the calling party identification, it has been proceeded according to the last call in the Auto CLIP Routing table. Now it is proceeded according to the relevant ringing table.
4.08rev8
• !!! Fixed the bug in previous revisions - Called numbes have been incorrectly presented in the list of called numbers on the key phone (some of them missed last digits and the last number had an additional 0 at the end). This bug could cause incorrect behaviour of AutoCLIP Routing.
4.08rev7
• !!! Fixed the bug in 4.08rev5 - If the cumulative length of all Text fields (name of the Short dial) is longer than 20 characters, following records couldn’t be saved correctly. This bug influented correct behaviour of the Event report SMSs too. If you have such configuration of the Short dials table, use this revision (or later) if doing upgrade to version 4.08! Use the configuration tool version 4.08D!
• !!! WARNING !!! Save the PBX configuration before upgrade to FW 4.08rev7. This upgrade automatically does the factory reset!!!
4.08rev5
• SMS Event reporting - info about: settings ganges, link failure, the SIM card credit, switch status etc.)
• Binary switch actions - send user SMS, block phones, block external lines, day/night switching, close contact relay).
• CLIR function - select if call would be made with identification or not. Could be associated to the key on the key phone. LED diode next to the key shines if CLIR is aktive.
• Fixed: DTMF sometimes not sent correctly from key phone to ISDN line
• Auto CLIP Routing enable/disable for each internal line separatelly (Internal lines/Enabling of services)
4.07rev9
• Fixed: Incorrect routing of incoming calls from CO line - AutoCLIP Routing service has been erroneously activated even in case when call has come over the CO line without CLIP identification.
4.07rev8
• Fixed – It hasn’t be able to make a short dial from the system (key) phone using service 80xx (fw version 4.07rev6)
• Fixed error in the GSM module trace – occasionally it could be found a fake alarm message in GSM trace „Some SMSs could be lost“ even when everything was OK (fw version 4.07rev6)
4.07rev6
• Auto CLIP routing feature.
• Italian menu on key (system) phones
4.06rev25
• !!! Fixed the risk of blocking system (key) phones – in the previous versions the next call to the busy system phone could sometimes cause blocking (workaround was to disable Internal lines/Enabling of services/Whole/Action/Next call ringing) !!!
4.06rev24
• Turkish menu on key (system) phones
• Tracing of the communication to key (system) phones – needed FW 2.70, at the system phone module
• Long distance prefix activated - Example: The long distance prefix is set. e.g. „0“. New call comes from the local country. If CLIP contains the international prefix of the country, that prefix is removed (must be set in the Configuration Tool too) and replaced with the long distance prefix. The modified CLIP is sent to the phone display and could be used for call back.
4.06rev18
• Hungarian language pack.
• Support of the older GSM modul FW versions 1.01 – 2.02. Older revisions of firmware 4.06 didn’t support those versions
4.06rev15
• Change in the forwarding to external lines – If the message „call is forwarded“ isn’t enabled, an incoming call to an extension, which is forwarded to a PSTN number, will not be picked up before it would be picked up at that PSTN number. In the previous versions, message has always been enabled and billing started even before the last destination has picked that call.
• Added option in ISDN line settings: „Don’t send request for AOC“ – blocks sending of facility Invoke AOC in the ISDN setup message. The ISDN modul firmware version ISM 16.01 is needed. Configuration tool version 4.06L or higher is needed.
4.06rev13
• Fixed critical error - blocking of key phones (caused by dat.acc and dat.dia file download)
• Fixed - In the case of ringing of a few extensions, if one picked up others had missed call
• Fixed - ME enable/disable couldn't be done from the ME mobile phone
2N® Omega Lite/ 2N® Omega 48 – Firmware
Release Notes EN
26.07.2010
!!! WARNING !!!
Upgrade from the firmware version 4.05 or earlier to the firmware version 4.06 or higher has to be done from the configuration tool corresponding to the target firmware version i.e 4.06, 4.07 etc. When you try to upgrade it from one of older versions, it causes destruction of data in the PBX. Then, firmware has to be uploaded from the boot (service) mode. You can get to the service mode using the lower button on the left side of the PBX. For details see the manual.
!!! The correct upgrade procedure:
- make a backup of your configuration in your original config tool e.g. 4.05
- install the newest version of the config tool (4.06, 4.07, 4.08)
- do the upgrade of the firmware from the installed config tool (4.06, 4.07, 4.08)
- download config from the PBX in new config tool
- open your stored configuration in the originál config tool and rewrite it manualy to the new config tool
- upload configuration from the new config tool to PBX
4.08rev10
• Searching in phone directory on system (key) phones using up to 3 leading characters. After that, it is possible to scroll the whole directory using < and > buttons.
• !!! Fixed the bug in previous revisions - If the call has come from UMTS or VoIP without the calling party identification, it has been proceeded according to the last call in the Auto CLIP Routing table. Now it is proceeded according to the relevant ringing table.
4.08rev8
• !!! Fixed the bug in previous revisions - Called numbes have been incorrectly presented in the list of called numbers on the key phone (some of them missed last digits and the last number had an additional 0 at the end). This bug could cause incorrect behaviour of AutoCLIP Routing.
4.08rev7
• !!! Fixed the bug in 4.08rev5 - If the cumulative length of all Text fields (name of the Short dial) is longer than 20 characters, following records couldn’t be saved correctly. This bug influented correct behaviour of the Event report SMSs too. If you have such configuration of the Short dials table, use this revision (or later) if doing upgrade to version 4.08! Use the configuration tool version 4.08D!
• !!! WARNING !!! Save the PBX configuration before upgrade to FW 4.08rev7. This upgrade automatically does the factory reset!!!
4.08rev5
• SMS Event reporting - info about: settings ganges, link failure, the SIM card credit, switch status etc.)
• Binary switch actions - send user SMS, block phones, block external lines, day/night switching, close contact relay).
• CLIR function - select if call would be made with identification or not. Could be associated to the key on the key phone. LED diode next to the key shines if CLIR is aktive.
• Fixed: DTMF sometimes not sent correctly from key phone to ISDN line
• Auto CLIP Routing enable/disable for each internal line separatelly (Internal lines/Enabling of services)
4.07rev9
• Fixed: Incorrect routing of incoming calls from CO line - AutoCLIP Routing service has been erroneously activated even in case when call has come over the CO line without CLIP identification.
4.07rev8
• Fixed – It hasn’t be able to make a short dial from the system (key) phone using service 80xx (fw version 4.07rev6)
• Fixed error in the GSM module trace – occasionally it could be found a fake alarm message in GSM trace „Some SMSs could be lost“ even when everything was OK (fw version 4.07rev6)
4.07rev6
• Auto CLIP routing feature.
• Italian menu on key (system) phones
4.06rev25
• !!! Fixed the risk of blocking system (key) phones – in the previous versions the next call to the busy system phone could sometimes cause blocking (workaround was to disable Internal lines/Enabling of services/Whole/Action/Next call ringing) !!!
4.06rev24
• Turkish menu on key (system) phones
• Tracing of the communication to key (system) phones – needed FW 2.70, at the system phone module
• Long distance prefix activated - Example: The long distance prefix is set. e.g. „0“. New call comes from the local country. If CLIP contains the international prefix of the country, that prefix is removed (must be set in the Configuration Tool too) and replaced with the long distance prefix. The modified CLIP is sent to the phone display and could be used for call back.
4.06rev18
• Hungarian language pack.
• Support of the older GSM modul FW versions 1.01 – 2.02. Older revisions of firmware 4.06 didn’t support those versions
4.06rev15
• Change in the forwarding to external lines – If the message „call is forwarded“ isn’t enabled, an incoming call to an extension, which is forwarded to a PSTN number, will not be picked up before it would be picked up at that PSTN number. In the previous versions, message has always been enabled and billing started even before the last destination has picked that call.
• Added option in ISDN line settings: „Don’t send request for AOC“ – blocks sending of facility Invoke AOC in the ISDN setup message. The ISDN modul firmware version ISM 16.01 is needed. Configuration tool version 4.06L or higher is needed.
4.06rev13
• Fixed critical error - blocking of key phones (caused by dat.acc and dat.dia file download)
• Fixed - In the case of ringing of a few extensions, if one picked up others had missed call
• Fixed - ME enable/disable couldn't be done from the ME mobile phone
Release Notes EN
26.07.2010
!!! WARNING !!!
Upgrade from the firmware version 4.05 or earlier to the firmware version 4.06 or higher has to be done from the configuration tool corresponding to the target firmware version i.e 4.06, 4.07 etc. When you try to upgrade it from one of older versions, it causes destruction of data in the PBX. Then, firmware has to be uploaded from the boot (service) mode. You can get to the service mode using the lower button on the left side of the PBX. For details see the manual.
!!! The correct upgrade procedure:
- make a backup of your configuration in your original config tool e.g. 4.05
- install the newest version of the config tool (4.06, 4.07, 4.08)
- do the upgrade of the firmware from the installed config tool (4.06, 4.07, 4.08)
- download config from the PBX in new config tool
- open your stored configuration in the originál config tool and rewrite it manualy to the new config tool
- upload configuration from the new config tool to PBX
4.08rev10
• Searching in phone directory on system (key) phones using up to 3 leading characters. After that, it is possible to scroll the whole directory using < and > buttons.
• !!! Fixed the bug in previous revisions - If the call has come from UMTS or VoIP without the calling party identification, it has been proceeded according to the last call in the Auto CLIP Routing table. Now it is proceeded according to the relevant ringing table.
4.08rev8
• !!! Fixed the bug in previous revisions - Called numbes have been incorrectly presented in the list of called numbers on the key phone (some of them missed last digits and the last number had an additional 0 at the end). This bug could cause incorrect behaviour of AutoCLIP Routing.
4.08rev7
• !!! Fixed the bug in 4.08rev5 - If the cumulative length of all Text fields (name of the Short dial) is longer than 20 characters, following records couldn’t be saved correctly. This bug influented correct behaviour of the Event report SMSs too. If you have such configuration of the Short dials table, use this revision (or later) if doing upgrade to version 4.08! Use the configuration tool version 4.08D!
• !!! WARNING !!! Save the PBX configuration before upgrade to FW 4.08rev7. This upgrade automatically does the factory reset!!!
4.08rev5
• SMS Event reporting - info about: settings ganges, link failure, the SIM card credit, switch status etc.)
• Binary switch actions - send user SMS, block phones, block external lines, day/night switching, close contact relay).
• CLIR function - select if call would be made with identification or not. Could be associated to the key on the key phone. LED diode next to the key shines if CLIR is aktive.
• Fixed: DTMF sometimes not sent correctly from key phone to ISDN line
• Auto CLIP Routing enable/disable for each internal line separatelly (Internal lines/Enabling of services)
4.07rev9
• Fixed: Incorrect routing of incoming calls from CO line - AutoCLIP Routing service has been erroneously activated even in case when call has come over the CO line without CLIP identification.
4.07rev8
• Fixed – It hasn’t be able to make a short dial from the system (key) phone using service 80xx (fw version 4.07rev6)
• Fixed error in the GSM module trace – occasionally it could be found a fake alarm message in GSM trace „Some SMSs could be lost“ even when everything was OK (fw version 4.07rev6)
4.07rev6
• Auto CLIP routing feature.
• Italian menu on key (system) phones
4.06rev25
• !!! Fixed the risk of blocking system (key) phones – in the previous versions the next call to the busy system phone could sometimes cause blocking (workaround was to disable Internal lines/Enabling of services/Whole/Action/Next call ringing) !!!
4.06rev24
• Turkish menu on key (system) phones
• Tracing of the communication to key (system) phones – needed FW 2.70, at the system phone module
• Long distance prefix activated - Example: The long distance prefix is set. e.g. „0“. New call comes from the local country. If CLIP contains the international prefix of the country, that prefix is removed (must be set in the Configuration Tool too) and replaced with the long distance prefix. The modified CLIP is sent to the phone display and could be used for call back.
4.06rev18
• Hungarian language pack.
• Support of the older GSM modul FW versions 1.01 – 2.02. Older revisions of firmware 4.06 didn’t support those versions
4.06rev15
• Change in the forwarding to external lines – If the message „call is forwarded“ isn’t enabled, an incoming call to an extension, which is forwarded to a PSTN number, will not be picked up before it would be picked up at that PSTN number. In the previous versions, message has always been enabled and billing started even before the last destination has picked that call.
• Added option in ISDN line settings: „Don’t send request for AOC“ – blocks sending of facility Invoke AOC in the ISDN setup message. The ISDN modul firmware version ISM 16.01 is needed. Configuration tool version 4.06L or higher is needed.
4.06rev13
• Fixed critical error - blocking of key phones (caused by dat.acc and dat.dia file download)
• Fixed - In the case of ringing of a few extensions, if one picked up others had missed call
• Fixed - ME enable/disable couldn't be done from the ME mobile phone
2N® Omega Lite/ 2N® Omega 48 – Firmware
Release Notes EN
26.07.2010
!!! WARNING !!!
Upgrade from the firmware version 4.05 or earlier to the firmware version 4.06 or higher has to be done from the configuration tool corresponding to the target firmware version i.e 4.06, 4.07 etc. When you try to upgrade it from one of older versions, it causes destruction of data in the PBX. Then, firmware has to be uploaded from the boot (service) mode. You can get to the service mode using the lower button on the left side of the PBX. For details see the manual.
!!! The correct upgrade procedure:
- make a backup of your configuration in your original config tool e.g. 4.05
- install the newest version of the config tool (4.06, 4.07, 4.08)
- do the upgrade of the firmware from the installed config tool (4.06, 4.07, 4.08)
- download config from the PBX in new config tool
- open your stored configuration in the originál config tool and rewrite it manualy to the new config tool
- upload configuration from the new config tool to PBX
4.08rev10
• Searching in phone directory on system (key) phones using up to 3 leading characters. After that, it is possible to scroll the whole directory using < and > buttons.
• !!! Fixed the bug in previous revisions - If the call has come from UMTS or VoIP without the calling party identification, it has been proceeded according to the last call in the Auto CLIP Routing table. Now it is proceeded according to the relevant ringing table.
4.08rev8
• !!! Fixed the bug in previous revisions - Called numbes have been incorrectly presented in the list of called numbers on the key phone (some of them missed last digits and the last number had an additional 0 at the end). This bug could cause incorrect behaviour of AutoCLIP Routing.
4.08rev7
• !!! Fixed the bug in 4.08rev5 - If the cumulative length of all Text fields (name of the Short dial) is longer than 20 characters, following records couldn’t be saved correctly. This bug influented correct behaviour of the Event report SMSs too. If you have such configuration of the Short dials table, use this revision (or later) if doing upgrade to version 4.08! Use the configuration tool version 4.08D!
• !!! WARNING !!! Save the PBX configuration before upgrade to FW 4.08rev7. This upgrade automatically does the factory reset!!!
4.08rev5
• SMS Event reporting - info about: settings ganges, link failure, the SIM card credit, switch status etc.)
• Binary switch actions - send user SMS, block phones, block external lines, day/night switching, close contact relay).
• CLIR function - select if call would be made with identification or not. Could be associated to the key on the key phone. LED diode next to the key shines if CLIR is aktive.
• Fixed: DTMF sometimes not sent correctly from key phone to ISDN line
• Auto CLIP Routing enable/disable for each internal line separatelly (Internal lines/Enabling of services)
4.07rev9
• Fixed: Incorrect routing of incoming calls from CO line - AutoCLIP Routing service has been erroneously activated even in case when call has come over the CO line without CLIP identification.
4.07rev8
• Fixed – It hasn’t be able to make a short dial from the system (key) phone using service 80xx (fw version 4.07rev6)
• Fixed error in the GSM module trace – occasionally it could be found a fake alarm message in GSM trace „Some SMSs could be lost“ even when everything was OK (fw version 4.07rev6)
4.07rev6
• Auto CLIP routing feature.
• Italian menu on key (system) phones
4.06rev25
• !!! Fixed the risk of blocking system (key) phones – in the previous versions the next call to the busy system phone could sometimes cause blocking (workaround was to disable Internal lines/Enabling of services/Whole/Action/Next call ringing) !!!
4.06rev24
• Turkish menu on key (system) phones
• Tracing of the communication to key (system) phones – needed FW 2.70, at the system phone module
• Long distance prefix activated - Example: The long distance prefix is set. e.g. „0“. New call comes from the local country. If CLIP contains the international prefix of the country, that prefix is removed (must be set in the Configuration Tool too) and replaced with the long distance prefix. The modified CLIP is sent to the phone display and could be used for call back.
4.06rev18
• Hungarian language pack.
• Support of the older GSM modul FW versions 1.01 – 2.02. Older revisions of firmware 4.06 didn’t support those versions
4.06rev15
• Change in the forwarding to external lines – If the message „call is forwarded“ isn’t enabled, an incoming call to an extension, which is forwarded to a PSTN number, will not be picked up before it would be picked up at that PSTN number. In the previous versions, message has always been enabled and billing started even before the last destination has picked that call.
• Added option in ISDN line settings: „Don’t send request for AOC“ – blocks sending of facility Invoke AOC in the ISDN setup message. The ISDN modul firmware version ISM 16.01 is needed. Configuration tool version 4.06L or higher is needed.
4.06rev13
• Fixed critical error - blocking of key phones (caused by dat.acc and dat.dia file download)
• Fixed - In the case of ringing of a few extensions, if one picked up others had missed call
• Fixed - ME enable/disable couldn't be done from the ME mobile phone
Release Notes EN
26.07.2010
!!! WARNING !!!
Upgrade from the firmware version 4.05 or earlier to the firmware version 4.06 or higher has to be done from the configuration tool corresponding to the target firmware version i.e 4.06, 4.07 etc. When you try to upgrade it from one of older versions, it causes destruction of data in the PBX. Then, firmware has to be uploaded from the boot (service) mode. You can get to the service mode using the lower button on the left side of the PBX. For details see the manual.
!!! The correct upgrade procedure:
- make a backup of your configuration in your original config tool e.g. 4.05
- install the newest version of the config tool (4.06, 4.07, 4.08)
- do the upgrade of the firmware from the installed config tool (4.06, 4.07, 4.08)
- download config from the PBX in new config tool
- open your stored configuration in the originál config tool and rewrite it manualy to the new config tool
- upload configuration from the new config tool to PBX
4.08rev10
• Searching in phone directory on system (key) phones using up to 3 leading characters. After that, it is possible to scroll the whole directory using < and > buttons.
• !!! Fixed the bug in previous revisions - If the call has come from UMTS or VoIP without the calling party identification, it has been proceeded according to the last call in the Auto CLIP Routing table. Now it is proceeded according to the relevant ringing table.
4.08rev8
• !!! Fixed the bug in previous revisions - Called numbes have been incorrectly presented in the list of called numbers on the key phone (some of them missed last digits and the last number had an additional 0 at the end). This bug could cause incorrect behaviour of AutoCLIP Routing.
4.08rev7
• !!! Fixed the bug in 4.08rev5 - If the cumulative length of all Text fields (name of the Short dial) is longer than 20 characters, following records couldn’t be saved correctly. This bug influented correct behaviour of the Event report SMSs too. If you have such configuration of the Short dials table, use this revision (or later) if doing upgrade to version 4.08! Use the configuration tool version 4.08D!
• !!! WARNING !!! Save the PBX configuration before upgrade to FW 4.08rev7. This upgrade automatically does the factory reset!!!
4.08rev5
• SMS Event reporting - info about: settings ganges, link failure, the SIM card credit, switch status etc.)
• Binary switch actions - send user SMS, block phones, block external lines, day/night switching, close contact relay).
• CLIR function - select if call would be made with identification or not. Could be associated to the key on the key phone. LED diode next to the key shines if CLIR is aktive.
• Fixed: DTMF sometimes not sent correctly from key phone to ISDN line
• Auto CLIP Routing enable/disable for each internal line separatelly (Internal lines/Enabling of services)
4.07rev9
• Fixed: Incorrect routing of incoming calls from CO line - AutoCLIP Routing service has been erroneously activated even in case when call has come over the CO line without CLIP identification.
4.07rev8
• Fixed – It hasn’t be able to make a short dial from the system (key) phone using service 80xx (fw version 4.07rev6)
• Fixed error in the GSM module trace – occasionally it could be found a fake alarm message in GSM trace „Some SMSs could be lost“ even when everything was OK (fw version 4.07rev6)
4.07rev6
• Auto CLIP routing feature.
• Italian menu on key (system) phones
4.06rev25
• !!! Fixed the risk of blocking system (key) phones – in the previous versions the next call to the busy system phone could sometimes cause blocking (workaround was to disable Internal lines/Enabling of services/Whole/Action/Next call ringing) !!!
4.06rev24
• Turkish menu on key (system) phones
• Tracing of the communication to key (system) phones – needed FW 2.70, at the system phone module
• Long distance prefix activated - Example: The long distance prefix is set. e.g. „0“. New call comes from the local country. If CLIP contains the international prefix of the country, that prefix is removed (must be set in the Configuration Tool too) and replaced with the long distance prefix. The modified CLIP is sent to the phone display and could be used for call back.
4.06rev18
• Hungarian language pack.
• Support of the older GSM modul FW versions 1.01 – 2.02. Older revisions of firmware 4.06 didn’t support those versions
4.06rev15
• Change in the forwarding to external lines – If the message „call is forwarded“ isn’t enabled, an incoming call to an extension, which is forwarded to a PSTN number, will not be picked up before it would be picked up at that PSTN number. In the previous versions, message has always been enabled and billing started even before the last destination has picked that call.
• Added option in ISDN line settings: „Don’t send request for AOC“ – blocks sending of facility Invoke AOC in the ISDN setup message. The ISDN modul firmware version ISM 16.01 is needed. Configuration tool version 4.06L or higher is needed.
4.06rev13
• Fixed critical error - blocking of key phones (caused by dat.acc and dat.dia file download)
• Fixed - In the case of ringing of a few extensions, if one picked up others had missed call
• Fixed - ME enable/disable couldn't be done from the ME mobile phone
2N® Omega Lite/ 2N® Omega 48 – Firmware
Release Notes EN
19.07.2010
!!! WARNING !!!
Upgrade from the firmware version 4.05 or earlier to the firmware version 4.06 or higher has to be done from the configuration tool corresponding to the target firmware version i.e 4.06, 4.07 etc. When you try to upgrade it from one of older versions, it causes destruction of data in the PBX. Then, firmware has to be uploaded from the boot (service) mode. You can get to the service mode using the lower button on the left side of the PBX. For details see the manual.
!!! The correct upgrade procedure:
- make a backup of your configuration in your original config tool e.g. 4.05
- install the newest version of the config tool (4.06, 4.07, 4.08)
- do the upgrade of the firmware from the installed config tool (4.06, 4.07, 4.08)
- download config from the PBX in new config tool
- open your stored configuration in the originál config tool and rewrite it manualy to the new config tool
- upload configuration from the new config tool to PBX
4.08rev8
• !!! Fixed the bug in previous revisions - Called numbes have been incorrectly presented in the list of called numbers on the key phone (some of them missed last digits and the last number had an additional 0 at the end). This bug could cause incorrect behaviour of AutoCLIP Routing.
4.08rev7
• !!! Fixed the bug in 4.08rev5 - If the cumulative length of all Text fields (name of the Short dial) is longer than 20 characters, following records couldn’t be saved correctly. This bug influented correct behaviour of the Event report SMSs too. If you have such configuration of the Short dials table, use this revision (or later) if doing upgrade to version 4.08! Use the configuration tool version 4.08D!
• !!! WARNING !!! Save the PBX configuration before upgrade to FW 4.08rev7. This upgrade automatically does the factory reset!!!
4.08rev5
• SMS Event reporting - info about: settings ganges, link failure, the SIM card credit, switch status etc.)
• Binary switch actions - send user SMS, block phones, block external lines, day/night switching, close contact relay).
• CLIR function - select if call would be made with identification or not. Could be associated to the key on the key phone. LED diode next to the key shines if CLIR is aktive.
• Fixed: DTMF sometimes not sent correctly from key phone to ISDN line
• Auto CLIP Routing enable/disable for each internal line separatelly (Internal lines/Enabling of services)
4.07rev9
• Fixed: Incorrect routing of incoming calls from CO line - AutoCLIP Routing service has been erroneously activated even in case when call has come over the CO line without CLIP identification.
4.07rev8
• Fixed – It hasn’t be able to make a short dial from the system (key) phone using service 80xx (fw version 4.07rev6)
• Fixed error in the GSM module trace – occasionally it could be found a fake alarm message in GSM trace „Some SMSs could be lost“ even when everything was OK (fw version 4.07rev6)
4.07rev6
• Auto CLIP routing feature.
• Italian menu on key (system) phones
4.06rev25
• !!! Fixed the risk of blocking system (key) phones – in the previous versions the next call to the busy system phone could sometimes cause blocking (workaround was to disable Internal lines/Enabling of services/Whole/Action/Next call ringing) !!!
4.06rev24
• Turkish menu on key (system) phones
• Tracing of the communication to key (system) phones – needed FW 2.70, at the system phone module
• Long distance prefix activated - Example: The long distance prefix is set. e.g. „0“. New call comes from the local country. If CLIP contains the international prefix of the country, that prefix is removed (must be set in the Configuration Tool too) and replaced with the long distance prefix. The modified CLIP is sent to the phone display and could be used for call back.
4.06rev18
• Hungarian language pack.
• Support of the older GSM modul FW versions 1.01 – 2.02. Older revisions of firmware 4.06 didn’t support those versions
4.06rev15
• Change in the forwarding to external lines – If the message „call is forwarded“ isn’t enabled, an incoming call to an extension, which is forwarded to a PSTN number, will not be picked up before it would be picked up at that PSTN number. In the previous versions, message has always been enabled and billing started even before the last destination has picked that call.
• Added option in ISDN line settings: „Don’t send request for AOC“ – blocks sending of facility Invoke AOC in the ISDN setup message. The ISDN modul firmware version ISM 16.01 is needed. Configuration tool version 4.06L or higher is needed.
4.06rev13
• Fixed critical error - blocking of key phones (caused by dat.acc and dat.dia file download)
• Fixed - In the case of ringing of a few extensions, if one picked up others had missed call
• Fixed - ME enable/disable couldn't be done from the ME mobile phone
Release Notes EN
19.07.2010
!!! WARNING !!!
Upgrade from the firmware version 4.05 or earlier to the firmware version 4.06 or higher has to be done from the configuration tool corresponding to the target firmware version i.e 4.06, 4.07 etc. When you try to upgrade it from one of older versions, it causes destruction of data in the PBX. Then, firmware has to be uploaded from the boot (service) mode. You can get to the service mode using the lower button on the left side of the PBX. For details see the manual.
!!! The correct upgrade procedure:
- make a backup of your configuration in your original config tool e.g. 4.05
- install the newest version of the config tool (4.06, 4.07, 4.08)
- do the upgrade of the firmware from the installed config tool (4.06, 4.07, 4.08)
- download config from the PBX in new config tool
- open your stored configuration in the originál config tool and rewrite it manualy to the new config tool
- upload configuration from the new config tool to PBX
4.08rev8
• !!! Fixed the bug in previous revisions - Called numbes have been incorrectly presented in the list of called numbers on the key phone (some of them missed last digits and the last number had an additional 0 at the end). This bug could cause incorrect behaviour of AutoCLIP Routing.
4.08rev7
• !!! Fixed the bug in 4.08rev5 - If the cumulative length of all Text fields (name of the Short dial) is longer than 20 characters, following records couldn’t be saved correctly. This bug influented correct behaviour of the Event report SMSs too. If you have such configuration of the Short dials table, use this revision (or later) if doing upgrade to version 4.08! Use the configuration tool version 4.08D!
• !!! WARNING !!! Save the PBX configuration before upgrade to FW 4.08rev7. This upgrade automatically does the factory reset!!!
4.08rev5
• SMS Event reporting - info about: settings ganges, link failure, the SIM card credit, switch status etc.)
• Binary switch actions - send user SMS, block phones, block external lines, day/night switching, close contact relay).
• CLIR function - select if call would be made with identification or not. Could be associated to the key on the key phone. LED diode next to the key shines if CLIR is aktive.
• Fixed: DTMF sometimes not sent correctly from key phone to ISDN line
• Auto CLIP Routing enable/disable for each internal line separatelly (Internal lines/Enabling of services)
4.07rev9
• Fixed: Incorrect routing of incoming calls from CO line - AutoCLIP Routing service has been erroneously activated even in case when call has come over the CO line without CLIP identification.
4.07rev8
• Fixed – It hasn’t be able to make a short dial from the system (key) phone using service 80xx (fw version 4.07rev6)
• Fixed error in the GSM module trace – occasionally it could be found a fake alarm message in GSM trace „Some SMSs could be lost“ even when everything was OK (fw version 4.07rev6)
4.07rev6
• Auto CLIP routing feature.
• Italian menu on key (system) phones
4.06rev25
• !!! Fixed the risk of blocking system (key) phones – in the previous versions the next call to the busy system phone could sometimes cause blocking (workaround was to disable Internal lines/Enabling of services/Whole/Action/Next call ringing) !!!
4.06rev24
• Turkish menu on key (system) phones
• Tracing of the communication to key (system) phones – needed FW 2.70, at the system phone module
• Long distance prefix activated - Example: The long distance prefix is set. e.g. „0“. New call comes from the local country. If CLIP contains the international prefix of the country, that prefix is removed (must be set in the Configuration Tool too) and replaced with the long distance prefix. The modified CLIP is sent to the phone display and could be used for call back.
4.06rev18
• Hungarian language pack.
• Support of the older GSM modul FW versions 1.01 – 2.02. Older revisions of firmware 4.06 didn’t support those versions
4.06rev15
• Change in the forwarding to external lines – If the message „call is forwarded“ isn’t enabled, an incoming call to an extension, which is forwarded to a PSTN number, will not be picked up before it would be picked up at that PSTN number. In the previous versions, message has always been enabled and billing started even before the last destination has picked that call.
• Added option in ISDN line settings: „Don’t send request for AOC“ – blocks sending of facility Invoke AOC in the ISDN setup message. The ISDN modul firmware version ISM 16.01 is needed. Configuration tool version 4.06L or higher is needed.
4.06rev13
• Fixed critical error - blocking of key phones (caused by dat.acc and dat.dia file download)
• Fixed - In the case of ringing of a few extensions, if one picked up others had missed call
• Fixed - ME enable/disable couldn't be done from the ME mobile phone
2N® Omega Lite/ 2N® Omega 48 – Firmware
Release Notes EN
19.07.2010
!!! WARNING !!!
Upgrade from the firmware version 4.05 or earlier to the firmware version 4.06 or higher has to be done from the configuration tool corresponding to the target firmware version i.e 4.06, 4.07 etc. When you try to upgrade it from one of older versions, it causes destruction of data in the PBX. Then, firmware has to be uploaded from the boot (service) mode. You can get to the service mode using the lower button on the left side of the PBX. For details see the manual.
!!! The correct upgrade procedure:
- make a backup of your configuration in your original config tool e.g. 4.05
- install the newest version of the config tool (4.06, 4.07, 4.08)
- do the upgrade of the firmware from the installed config tool (4.06, 4.07, 4.08)
- download config from the PBX in new config tool
- open your stored configuration in the originál config tool and rewrite it manualy to the new config tool
- upload configuration from the new config tool to PBX
4.08rev8
• !!! Fixed the bug in previous revisions - Called numbes have been incorrectly presented in the list of called numbers on the key phone (some of them missed last digits and the last number had an additional 0 at the end). This bug could cause incorrect behaviour of AutoCLIP Routing.
4.08rev7
• !!! Fixed the bug in 4.08rev5 - If the cumulative length of all Text fields (name of the Short dial) is longer than 20 characters, following records couldn’t be saved correctly. This bug influented correct behaviour of the Event report SMSs too. If you have such configuration of the Short dials table, use this revision (or later) if doing upgrade to version 4.08! Use the configuration tool version 4.08D!
• !!! WARNING !!! Save the PBX configuration before upgrade to FW 4.08rev7. This upgrade automatically does the factory reset!!!
4.08rev5
• SMS Event reporting - info about: settings ganges, link failure, the SIM card credit, switch status etc.)
• Binary switch actions - send user SMS, block phones, block external lines, day/night switching, close contact relay).
• CLIR function - select if call would be made with identification or not. Could be associated to the key on the key phone. LED diode next to the key shines if CLIR is aktive.
• Fixed: DTMF sometimes not sent correctly from key phone to ISDN line
• Auto CLIP Routing enable/disable for each internal line separatelly (Internal lines/Enabling of services)
4.07rev9
• Fixed: Incorrect routing of incoming calls from CO line - AutoCLIP Routing service has been erroneously activated even in case when call has come over the CO line without CLIP identification.
4.07rev8
• Fixed – It hasn’t be able to make a short dial from the system (key) phone using service 80xx (fw version 4.07rev6)
• Fixed error in the GSM module trace – occasionally it could be found a fake alarm message in GSM trace „Some SMSs could be lost“ even when everything was OK (fw version 4.07rev6)
4.07rev6
• Auto CLIP routing feature.
• Italian menu on key (system) phones
4.06rev25
• !!! Fixed the risk of blocking system (key) phones – in the previous versions the next call to the busy system phone could sometimes cause blocking (workaround was to disable Internal lines/Enabling of services/Whole/Action/Next call ringing) !!!
4.06rev24
• Turkish menu on key (system) phones
• Tracing of the communication to key (system) phones – needed FW 2.70, at the system phone module
• Long distance prefix activated - Example: The long distance prefix is set. e.g. „0“. New call comes from the local country. If CLIP contains the international prefix of the country, that prefix is removed (must be set in the Configuration Tool too) and replaced with the long distance prefix. The modified CLIP is sent to the phone display and could be used for call back.
4.06rev18
• Hungarian language pack.
• Support of the older GSM modul FW versions 1.01 – 2.02. Older revisions of firmware 4.06 didn’t support those versions
4.06rev15
• Change in the forwarding to external lines – If the message „call is forwarded“ isn’t enabled, an incoming call to an extension, which is forwarded to a PSTN number, will not be picked up before it would be picked up at that PSTN number. In the previous versions, message has always been enabled and billing started even before the last destination has picked that call.
• Added option in ISDN line settings: „Don’t send request for AOC“ – blocks sending of facility Invoke AOC in the ISDN setup message. The ISDN modul firmware version ISM 16.01 is needed. Configuration tool version 4.06L or higher is needed.
4.06rev13
• Fixed critical error - blocking of key phones (caused by dat.acc and dat.dia file download)
• Fixed - In the case of ringing of a few extensions, if one picked up others had missed call
• Fixed - ME enable/disable couldn't be done from the ME mobile phone
Release Notes EN
19.07.2010
!!! WARNING !!!
Upgrade from the firmware version 4.05 or earlier to the firmware version 4.06 or higher has to be done from the configuration tool corresponding to the target firmware version i.e 4.06, 4.07 etc. When you try to upgrade it from one of older versions, it causes destruction of data in the PBX. Then, firmware has to be uploaded from the boot (service) mode. You can get to the service mode using the lower button on the left side of the PBX. For details see the manual.
!!! The correct upgrade procedure:
- make a backup of your configuration in your original config tool e.g. 4.05
- install the newest version of the config tool (4.06, 4.07, 4.08)
- do the upgrade of the firmware from the installed config tool (4.06, 4.07, 4.08)
- download config from the PBX in new config tool
- open your stored configuration in the originál config tool and rewrite it manualy to the new config tool
- upload configuration from the new config tool to PBX
4.08rev8
• !!! Fixed the bug in previous revisions - Called numbes have been incorrectly presented in the list of called numbers on the key phone (some of them missed last digits and the last number had an additional 0 at the end). This bug could cause incorrect behaviour of AutoCLIP Routing.
4.08rev7
• !!! Fixed the bug in 4.08rev5 - If the cumulative length of all Text fields (name of the Short dial) is longer than 20 characters, following records couldn’t be saved correctly. This bug influented correct behaviour of the Event report SMSs too. If you have such configuration of the Short dials table, use this revision (or later) if doing upgrade to version 4.08! Use the configuration tool version 4.08D!
• !!! WARNING !!! Save the PBX configuration before upgrade to FW 4.08rev7. This upgrade automatically does the factory reset!!!
4.08rev5
• SMS Event reporting - info about: settings ganges, link failure, the SIM card credit, switch status etc.)
• Binary switch actions - send user SMS, block phones, block external lines, day/night switching, close contact relay).
• CLIR function - select if call would be made with identification or not. Could be associated to the key on the key phone. LED diode next to the key shines if CLIR is aktive.
• Fixed: DTMF sometimes not sent correctly from key phone to ISDN line
• Auto CLIP Routing enable/disable for each internal line separatelly (Internal lines/Enabling of services)
4.07rev9
• Fixed: Incorrect routing of incoming calls from CO line - AutoCLIP Routing service has been erroneously activated even in case when call has come over the CO line without CLIP identification.
4.07rev8
• Fixed – It hasn’t be able to make a short dial from the system (key) phone using service 80xx (fw version 4.07rev6)
• Fixed error in the GSM module trace – occasionally it could be found a fake alarm message in GSM trace „Some SMSs could be lost“ even when everything was OK (fw version 4.07rev6)
4.07rev6
• Auto CLIP routing feature.
• Italian menu on key (system) phones
4.06rev25
• !!! Fixed the risk of blocking system (key) phones – in the previous versions the next call to the busy system phone could sometimes cause blocking (workaround was to disable Internal lines/Enabling of services/Whole/Action/Next call ringing) !!!
4.06rev24
• Turkish menu on key (system) phones
• Tracing of the communication to key (system) phones – needed FW 2.70, at the system phone module
• Long distance prefix activated - Example: The long distance prefix is set. e.g. „0“. New call comes from the local country. If CLIP contains the international prefix of the country, that prefix is removed (must be set in the Configuration Tool too) and replaced with the long distance prefix. The modified CLIP is sent to the phone display and could be used for call back.
4.06rev18
• Hungarian language pack.
• Support of the older GSM modul FW versions 1.01 – 2.02. Older revisions of firmware 4.06 didn’t support those versions
4.06rev15
• Change in the forwarding to external lines – If the message „call is forwarded“ isn’t enabled, an incoming call to an extension, which is forwarded to a PSTN number, will not be picked up before it would be picked up at that PSTN number. In the previous versions, message has always been enabled and billing started even before the last destination has picked that call.
• Added option in ISDN line settings: „Don’t send request for AOC“ – blocks sending of facility Invoke AOC in the ISDN setup message. The ISDN modul firmware version ISM 16.01 is needed. Configuration tool version 4.06L or higher is needed.
4.06rev13
• Fixed critical error - blocking of key phones (caused by dat.acc and dat.dia file download)
• Fixed - In the case of ringing of a few extensions, if one picked up others had missed call
• Fixed - ME enable/disable couldn't be done from the ME mobile phone
2N® Omega Lite / 2N® Omega 48 - Ethernet module firmware
Release Notes
21.02.2010
OLI-2-3-6 2010-02-21
• This version is displayed in web configuration interface as 2.3.6a
• !!! Fixed the critical bug – Calling from VoIP to analogue or system phone extension, that has an active voicemail, calling party could listen messages left in the called party voice mailbox. (since firmware 2.3.2)
• Xapi 2.01N
OLI-2-3-5 2009-12-23
• Backup of configuration contains only configuration folders
• Web interface – the lower left angle icons are unified in various menus
• XAPI 2.01J – fixed problem of firmware upgrade from the configuration tool, over port 1234
• PPP – significantly improved uplink data rate over UMTS module
• Web interface - improved response time
• Ring Groups - VoIP phones (extensions) could be rang together
• new default password of Admin is 2n
• DNS – fixed problem of cyclical rebooting of Ethernet module – It happened if DNS proxy was enabled and DNS servers haven’t been set
• SIP - header Diversion
• Fixed the problem with Sierra module – if RING has come during SMS sending, SMS was treated as not sent
• Voicemail – warning about almost filled up message space
OLI-2-3-2 2009-11-04
• DISA message in Ethernet module – new settings – fall to the default operator, maximal duration of the voice mail message, improved voice quality of messages
• Listen port displayed in the SIP lines menu
• H.323 – the calling party identification in incomming calls- corrected
• QoS indication could be set for RTP and SIP
• XAPI 2.01H
OLI-2-3-1 2009-09-23
• integrated XAPI server
• new, more reliable H.323 stack
• DISA - interdigit timeout, limited call duration, cycling limit
• default IP address 192.168.1.1
2N® Omega Lite/ 2N® Omega 48 – Firmware
Release Notes EN
15.03.2010
!!! CAUTION !!!
Upgrade from the firmware version 4.05 or earlier to the firmware version 4.06 or higher has to be done from the configuration tool corresponding to the target firmware version i.e 4.06, 4.07 etc. When you try to upgrade it from one of older versions, it causes destruction of data in the PBX. Then, firmware has to be uploaded from the boot (service) mode. You can get to the service mode using the lower button on the left side of the PBX. For details see the manual.
!!! The correct upgrade procedure:
- make a backup of your configuration in your previous config tool
- install the newest version of the config tool (4.06, 4.07)
- do the upgrade of the firmware from the installed config tool (4.06, 4.07)
- download config from the PBX, open your stored configuration, upload it to the PBX or rewrite it manuály
4.07rev9
• Fixed: Incorrect routing of incoming calls from CO line - AutoCLIP Routing service has been erroneously activated even in case when call has come over the CO line without CLIP identification.
4.07rev8
• Fixed – It hasn’t be able to make a short dial from the system (key) phone using service 80xx (fw version 4.07rev6)
• Fixed error in the GSM module trace – occasionally it could be found a fake alarm message in GSM trace „Some SMSs could be lost“ even when everything was OK (fw version 4.07rev6)
4.07rev6
• Auto CLIP routing feature.
• Italian menu on key (system) phones
4.06rev25
• !!! Fixed the risk of blocking system (key) phones – in the previous versions the next call to the busy system phone could sometimes cause blocking (workaround was to disable Internal lines/Enabling of services/Whole/Action/Next call ringing) !!!
4.06rev24
• Turkish menu on key (system) phones
• Tracing of the communication to key (system) phones – needed FW 2.70, at the system phone module
• Long distance prefix activated - Example: The long distance prefix is set. e.g. „0“. New call comes from the local country. If CLIP contains the international prefix of the country, that prefix is removed (must be set in the Configuration Tool too) and replaced with the long distance prefix. The modified CLIP is sent to the phone display and could be used for call back.
4.06rev18
• Hungarian language pack.
• Support of the older GSM modul FW versions 1.01 – 2.02. Older revisions of firmware 4.06 didn’t support those versions
4.06rev15
• Change in the forwarding to external lines – If the message „call is forwarded“ isn’t enabled, an incoming call to an extension, which is forwarded to a PSTN number, will not be picked up before it would be picked up at that PSTN number. In the previous versions, message has always been enabled and billing started even before the last destination has picked that call.
• Added option in ISDN line settings: „Don’t send request for AOC“ – blocks sending of facility Invoke AOC in the ISDN setup message. The ISDN modul firmware version ISM 16.01 is needed. Configuration tool version 4.06L or higher is needed.
4.06rev13
• Fixed critical error - blocking of key phones (caused by dat.acc and dat.dia file download)
• Fixed - In the case of ringing of a few extensions, if one picked up others had missed call
• Fixed - ME enable/disable couldn't be done from the ME mobile phone
Release Notes EN
15.03.2010
!!! CAUTION !!!
Upgrade from the firmware version 4.05 or earlier to the firmware version 4.06 or higher has to be done from the configuration tool corresponding to the target firmware version i.e 4.06, 4.07 etc. When you try to upgrade it from one of older versions, it causes destruction of data in the PBX. Then, firmware has to be uploaded from the boot (service) mode. You can get to the service mode using the lower button on the left side of the PBX. For details see the manual.
!!! The correct upgrade procedure:
- make a backup of your configuration in your previous config tool
- install the newest version of the config tool (4.06, 4.07)
- do the upgrade of the firmware from the installed config tool (4.06, 4.07)
- download config from the PBX, open your stored configuration, upload it to the PBX or rewrite it manuály
4.07rev9
• Fixed: Incorrect routing of incoming calls from CO line - AutoCLIP Routing service has been erroneously activated even in case when call has come over the CO line without CLIP identification.
4.07rev8
• Fixed – It hasn’t be able to make a short dial from the system (key) phone using service 80xx (fw version 4.07rev6)
• Fixed error in the GSM module trace – occasionally it could be found a fake alarm message in GSM trace „Some SMSs could be lost“ even when everything was OK (fw version 4.07rev6)
4.07rev6
• Auto CLIP routing feature.
• Italian menu on key (system) phones
4.06rev25
• !!! Fixed the risk of blocking system (key) phones – in the previous versions the next call to the busy system phone could sometimes cause blocking (workaround was to disable Internal lines/Enabling of services/Whole/Action/Next call ringing) !!!
4.06rev24
• Turkish menu on key (system) phones
• Tracing of the communication to key (system) phones – needed FW 2.70, at the system phone module
• Long distance prefix activated - Example: The long distance prefix is set. e.g. „0“. New call comes from the local country. If CLIP contains the international prefix of the country, that prefix is removed (must be set in the Configuration Tool too) and replaced with the long distance prefix. The modified CLIP is sent to the phone display and could be used for call back.
4.06rev18
• Hungarian language pack.
• Support of the older GSM modul FW versions 1.01 – 2.02. Older revisions of firmware 4.06 didn’t support those versions
4.06rev15
• Change in the forwarding to external lines – If the message „call is forwarded“ isn’t enabled, an incoming call to an extension, which is forwarded to a PSTN number, will not be picked up before it would be picked up at that PSTN number. In the previous versions, message has always been enabled and billing started even before the last destination has picked that call.
• Added option in ISDN line settings: „Don’t send request for AOC“ – blocks sending of facility Invoke AOC in the ISDN setup message. The ISDN modul firmware version ISM 16.01 is needed. Configuration tool version 4.06L or higher is needed.
4.06rev13
• Fixed critical error - blocking of key phones (caused by dat.acc and dat.dia file download)
• Fixed - In the case of ringing of a few extensions, if one picked up others had missed call
• Fixed - ME enable/disable couldn't be done from the ME mobile phone
2N® Omega Lite/ 2N® Omega 48 – Firmware
Release Notes EN
30.05.2010
!!! WARNING !!!
Upgrade from the firmware version 4.05 or earlier to the firmware version 4.06 or higher has to be done from the configuration tool corresponding to the target firmware version i.e 4.06, 4.07 etc. When you try to upgrade it from one of older versions, it causes destruction of data in the PBX. Then, firmware has to be uploaded from the boot (service) mode. You can get to the service mode using the lower button on the left side of the PBX. For details see the manual.
!!! The correct upgrade procedure:
- make a backup of your configuration in your original config tool e.g. 4.05
- install the newest version of the config tool (4.06, 4.07, 4.08)
- do the upgrade of the firmware from the installed config tool (4.06, 4.07, 4.08)
- download config from the PBX in new config tool
- open your stored configuration in the originál config tool and rewrite it manualy to the new config tool
- upload configuration from the new config tool to PBX
4.08rev7
• !!! Fixed the bug in 4.08rev5 - If the cumulative length of all Text fields (name of the Short dial) is longer than 20 characters, following records couldn’t be saved correctly. This bug influented correct behaviour of the Event report SMSs too. If you have such configuration of the Short dials table, use this revision (or later) if doing upgrade to version 4.08! Use the configuration tool version 4.08D!
4.08rev5
• SMS Event reporting - info about: settings ganges, link failure, the SIM card credit, switch status etc.)
• Binary switch actions - send user SMS, block phones, block external lines, day/night switching, close contact relay).
• CLIR function - select if call would be made with identification or not. Could be associated to the key on the key phone. LED diode next to the key shines if CLIR is aktive.
• Fixed: DTMF sometimes not sent correctly from key phone to ISDN line
• Auto CLIP Routing enable/disable for each internal line separatelly (Internal lines/Enabling of services)
4.07rev9
• Fixed: Incorrect routing of incoming calls from CO line - AutoCLIP Routing service has been erroneously activated even in case when call has come over the CO line without CLIP identification.
4.07rev8
• Fixed – It hasn’t be able to make a short dial from the system (key) phone using service 80xx (fw version 4.07rev6)
• Fixed error in the GSM module trace – occasionally it could be found a fake alarm message in GSM trace „Some SMSs could be lost“ even when everything was OK (fw version 4.07rev6)
4.07rev6
• Auto CLIP routing feature.
• Italian menu on key (system) phones
4.06rev25
• !!! Fixed the risk of blocking system (key) phones – in the previous versions the next call to the busy system phone could sometimes cause blocking (workaround was to disable Internal lines/Enabling of services/Whole/Action/Next call ringing) !!!
4.06rev24
• Turkish menu on key (system) phones
• Tracing of the communication to key (system) phones – needed FW 2.70, at the system phone module
• Long distance prefix activated - Example: The long distance prefix is set. e.g. „0“. New call comes from the local country. If CLIP contains the international prefix of the country, that prefix is removed (must be set in the Configuration Tool too) and replaced with the long distance prefix. The modified CLIP is sent to the phone display and could be used for call back.
4.06rev18
• Hungarian language pack.
• Support of the older GSM modul FW versions 1.01 – 2.02. Older revisions of firmware 4.06 didn’t support those versions
4.06rev15
• Change in the forwarding to external lines – If the message „call is forwarded“ isn’t enabled, an incoming call to an extension, which is forwarded to a PSTN number, will not be picked up before it would be picked up at that PSTN number. In the previous versions, message has always been enabled and billing started even before the last destination has picked that call.
• Added option in ISDN line settings: „Don’t send request for AOC“ – blocks sending of facility Invoke AOC in the ISDN setup message. The ISDN modul firmware version ISM 16.01 is needed. Configuration tool version 4.06L or higher is needed.
4.06rev13
• Fixed critical error - blocking of key phones (caused by dat.acc and dat.dia file download)
• Fixed - In the case of ringing of a few extensions, if one picked up others had missed call
• Fixed - ME enable/disable couldn't be done from the ME mobile phone
Release Notes EN
30.05.2010
!!! WARNING !!!
Upgrade from the firmware version 4.05 or earlier to the firmware version 4.06 or higher has to be done from the configuration tool corresponding to the target firmware version i.e 4.06, 4.07 etc. When you try to upgrade it from one of older versions, it causes destruction of data in the PBX. Then, firmware has to be uploaded from the boot (service) mode. You can get to the service mode using the lower button on the left side of the PBX. For details see the manual.
!!! The correct upgrade procedure:
- make a backup of your configuration in your original config tool e.g. 4.05
- install the newest version of the config tool (4.06, 4.07, 4.08)
- do the upgrade of the firmware from the installed config tool (4.06, 4.07, 4.08)
- download config from the PBX in new config tool
- open your stored configuration in the originál config tool and rewrite it manualy to the new config tool
- upload configuration from the new config tool to PBX
4.08rev7
• !!! Fixed the bug in 4.08rev5 - If the cumulative length of all Text fields (name of the Short dial) is longer than 20 characters, following records couldn’t be saved correctly. This bug influented correct behaviour of the Event report SMSs too. If you have such configuration of the Short dials table, use this revision (or later) if doing upgrade to version 4.08! Use the configuration tool version 4.08D!
4.08rev5
• SMS Event reporting - info about: settings ganges, link failure, the SIM card credit, switch status etc.)
• Binary switch actions - send user SMS, block phones, block external lines, day/night switching, close contact relay).
• CLIR function - select if call would be made with identification or not. Could be associated to the key on the key phone. LED diode next to the key shines if CLIR is aktive.
• Fixed: DTMF sometimes not sent correctly from key phone to ISDN line
• Auto CLIP Routing enable/disable for each internal line separatelly (Internal lines/Enabling of services)
4.07rev9
• Fixed: Incorrect routing of incoming calls from CO line - AutoCLIP Routing service has been erroneously activated even in case when call has come over the CO line without CLIP identification.
4.07rev8
• Fixed – It hasn’t be able to make a short dial from the system (key) phone using service 80xx (fw version 4.07rev6)
• Fixed error in the GSM module trace – occasionally it could be found a fake alarm message in GSM trace „Some SMSs could be lost“ even when everything was OK (fw version 4.07rev6)
4.07rev6
• Auto CLIP routing feature.
• Italian menu on key (system) phones
4.06rev25
• !!! Fixed the risk of blocking system (key) phones – in the previous versions the next call to the busy system phone could sometimes cause blocking (workaround was to disable Internal lines/Enabling of services/Whole/Action/Next call ringing) !!!
4.06rev24
• Turkish menu on key (system) phones
• Tracing of the communication to key (system) phones – needed FW 2.70, at the system phone module
• Long distance prefix activated - Example: The long distance prefix is set. e.g. „0“. New call comes from the local country. If CLIP contains the international prefix of the country, that prefix is removed (must be set in the Configuration Tool too) and replaced with the long distance prefix. The modified CLIP is sent to the phone display and could be used for call back.
4.06rev18
• Hungarian language pack.
• Support of the older GSM modul FW versions 1.01 – 2.02. Older revisions of firmware 4.06 didn’t support those versions
4.06rev15
• Change in the forwarding to external lines – If the message „call is forwarded“ isn’t enabled, an incoming call to an extension, which is forwarded to a PSTN number, will not be picked up before it would be picked up at that PSTN number. In the previous versions, message has always been enabled and billing started even before the last destination has picked that call.
• Added option in ISDN line settings: „Don’t send request for AOC“ – blocks sending of facility Invoke AOC in the ISDN setup message. The ISDN modul firmware version ISM 16.01 is needed. Configuration tool version 4.06L or higher is needed.
4.06rev13
• Fixed critical error - blocking of key phones (caused by dat.acc and dat.dia file download)
• Fixed - In the case of ringing of a few extensions, if one picked up others had missed call
• Fixed - ME enable/disable couldn't be done from the ME mobile phone
2N® Omega Lite/ 2N® Omega 48 – Firmware
Release Notes EN
30.05.2010
!!! WARNING !!!
Upgrade from the firmware version 4.05 or earlier to the firmware version 4.06 or higher has to be done from the configuration tool corresponding to the target firmware version i.e 4.06, 4.07 etc. When you try to upgrade it from one of older versions, it causes destruction of data in the PBX. Then, firmware has to be uploaded from the boot (service) mode. You can get to the service mode using the lower button on the left side of the PBX. For details see the manual.
!!! The correct upgrade procedure:
- make a backup of your configuration in your original config tool e.g. 4.05
- install the newest version of the config tool (4.06, 4.07, 4.08)
- do the upgrade of the firmware from the installed config tool (4.06, 4.07, 4.08)
- download config from the PBX in new config tool
- open your stored configuration in the originál config tool and rewrite it manualy to the new config tool
- upload configuration from the new config tool to PBX
4.08rev7
• !!! Fixed the bug in 4.08rev5 - If the cumulative length of all Text fields (name of the Short dial) is longer than 20 characters, following records couldn’t be saved correctly. This bug influented correct behaviour of the Event report SMSs too. If you have such configuration of the Short dials table, use this revision (or later) if doing upgrade to version 4.08! Use the configuration tool version 4.08D!
• !!! WARNING !!! Save the PBX configuration before upgrade to FW 4.08rev7. This upgrade automatically does the factory reset!!!
4.08rev5
• SMS Event reporting - info about: settings ganges, link failure, the SIM card credit, switch status etc.)
• Binary switch actions - send user SMS, block phones, block external lines, day/night switching, close contact relay).
• CLIR function - select if call would be made with identification or not. Could be associated to the key on the key phone. LED diode next to the key shines if CLIR is aktive.
• Fixed: DTMF sometimes not sent correctly from key phone to ISDN line
• Auto CLIP Routing enable/disable for each internal line separatelly (Internal lines/Enabling of services)
4.07rev9
• Fixed: Incorrect routing of incoming calls from CO line - AutoCLIP Routing service has been erroneously activated even in case when call has come over the CO line without CLIP identification.
4.07rev8
• Fixed – It hasn’t be able to make a short dial from the system (key) phone using service 80xx (fw version 4.07rev6)
• Fixed error in the GSM module trace – occasionally it could be found a fake alarm message in GSM trace „Some SMSs could be lost“ even when everything was OK (fw version 4.07rev6)
4.07rev6
• Auto CLIP routing feature.
• Italian menu on key (system) phones
4.06rev25
• !!! Fixed the risk of blocking system (key) phones – in the previous versions the next call to the busy system phone could sometimes cause blocking (workaround was to disable Internal lines/Enabling of services/Whole/Action/Next call ringing) !!!
4.06rev24
• Turkish menu on key (system) phones
• Tracing of the communication to key (system) phones – needed FW 2.70, at the system phone module
• Long distance prefix activated - Example: The long distance prefix is set. e.g. „0“. New call comes from the local country. If CLIP contains the international prefix of the country, that prefix is removed (must be set in the Configuration Tool too) and replaced with the long distance prefix. The modified CLIP is sent to the phone display and could be used for call back.
4.06rev18
• Hungarian language pack.
• Support of the older GSM modul FW versions 1.01 – 2.02. Older revisions of firmware 4.06 didn’t support those versions
4.06rev15
• Change in the forwarding to external lines – If the message „call is forwarded“ isn’t enabled, an incoming call to an extension, which is forwarded to a PSTN number, will not be picked up before it would be picked up at that PSTN number. In the previous versions, message has always been enabled and billing started even before the last destination has picked that call.
• Added option in ISDN line settings: „Don’t send request for AOC“ – blocks sending of facility Invoke AOC in the ISDN setup message. The ISDN modul firmware version ISM 16.01 is needed. Configuration tool version 4.06L or higher is needed.
4.06rev13
• Fixed critical error - blocking of key phones (caused by dat.acc and dat.dia file download)
• Fixed - In the case of ringing of a few extensions, if one picked up others had missed call
• Fixed - ME enable/disable couldn't be done from the ME mobile phone
Release Notes EN
30.05.2010
!!! WARNING !!!
Upgrade from the firmware version 4.05 or earlier to the firmware version 4.06 or higher has to be done from the configuration tool corresponding to the target firmware version i.e 4.06, 4.07 etc. When you try to upgrade it from one of older versions, it causes destruction of data in the PBX. Then, firmware has to be uploaded from the boot (service) mode. You can get to the service mode using the lower button on the left side of the PBX. For details see the manual.
!!! The correct upgrade procedure:
- make a backup of your configuration in your original config tool e.g. 4.05
- install the newest version of the config tool (4.06, 4.07, 4.08)
- do the upgrade of the firmware from the installed config tool (4.06, 4.07, 4.08)
- download config from the PBX in new config tool
- open your stored configuration in the originál config tool and rewrite it manualy to the new config tool
- upload configuration from the new config tool to PBX
4.08rev7
• !!! Fixed the bug in 4.08rev5 - If the cumulative length of all Text fields (name of the Short dial) is longer than 20 characters, following records couldn’t be saved correctly. This bug influented correct behaviour of the Event report SMSs too. If you have such configuration of the Short dials table, use this revision (or later) if doing upgrade to version 4.08! Use the configuration tool version 4.08D!
• !!! WARNING !!! Save the PBX configuration before upgrade to FW 4.08rev7. This upgrade automatically does the factory reset!!!
4.08rev5
• SMS Event reporting - info about: settings ganges, link failure, the SIM card credit, switch status etc.)
• Binary switch actions - send user SMS, block phones, block external lines, day/night switching, close contact relay).
• CLIR function - select if call would be made with identification or not. Could be associated to the key on the key phone. LED diode next to the key shines if CLIR is aktive.
• Fixed: DTMF sometimes not sent correctly from key phone to ISDN line
• Auto CLIP Routing enable/disable for each internal line separatelly (Internal lines/Enabling of services)
4.07rev9
• Fixed: Incorrect routing of incoming calls from CO line - AutoCLIP Routing service has been erroneously activated even in case when call has come over the CO line without CLIP identification.
4.07rev8
• Fixed – It hasn’t be able to make a short dial from the system (key) phone using service 80xx (fw version 4.07rev6)
• Fixed error in the GSM module trace – occasionally it could be found a fake alarm message in GSM trace „Some SMSs could be lost“ even when everything was OK (fw version 4.07rev6)
4.07rev6
• Auto CLIP routing feature.
• Italian menu on key (system) phones
4.06rev25
• !!! Fixed the risk of blocking system (key) phones – in the previous versions the next call to the busy system phone could sometimes cause blocking (workaround was to disable Internal lines/Enabling of services/Whole/Action/Next call ringing) !!!
4.06rev24
• Turkish menu on key (system) phones
• Tracing of the communication to key (system) phones – needed FW 2.70, at the system phone module
• Long distance prefix activated - Example: The long distance prefix is set. e.g. „0“. New call comes from the local country. If CLIP contains the international prefix of the country, that prefix is removed (must be set in the Configuration Tool too) and replaced with the long distance prefix. The modified CLIP is sent to the phone display and could be used for call back.
4.06rev18
• Hungarian language pack.
• Support of the older GSM modul FW versions 1.01 – 2.02. Older revisions of firmware 4.06 didn’t support those versions
4.06rev15
• Change in the forwarding to external lines – If the message „call is forwarded“ isn’t enabled, an incoming call to an extension, which is forwarded to a PSTN number, will not be picked up before it would be picked up at that PSTN number. In the previous versions, message has always been enabled and billing started even before the last destination has picked that call.
• Added option in ISDN line settings: „Don’t send request for AOC“ – blocks sending of facility Invoke AOC in the ISDN setup message. The ISDN modul firmware version ISM 16.01 is needed. Configuration tool version 4.06L or higher is needed.
4.06rev13
• Fixed critical error - blocking of key phones (caused by dat.acc and dat.dia file download)
• Fixed - In the case of ringing of a few extensions, if one picked up others had missed call
• Fixed - ME enable/disable couldn't be done from the ME mobile phone
2N SmartCom - Release Notes
20.3.2012
verze 1.3.3 (1.3.3.3.4) 2011-12-07
* FIXED - lost of the PIN settings during the upgrade from fw version 1.3.0 and older
verze 1.4.0 (1.4.0.4.3) 2011-12-22
* AT API - access to the SmC Server from third-party applications
* time scheaduling of the firmware upgrade
* a few fixes
* upgrade of firmware from Terminal Config program over RS232 (Terminal Config
is not on the CD and the procedure is not explained in the manual)
version 1.5.0 (1.5.0.5.2) 2012-03-20
* UDF - user defined functions in SmC terminal - independent of the SmC Server
* import and export of the SmC Server database available to the user
* Access to the configuration port of SmC from SmC Server
* SmC Server code optimization - thousands of SmC terminals are supported over TCP
* Control Panel - a few fixes and improvements
* !!! FIXED problem of not-working on 850MHz and 1900MHz !!! Quadband is automatically activated
* Manual - upgrade of firmware from Terminal Config program over RS232 (already in 1.4.0, but
previously not explained in the manual)
20.3.2012
verze 1.3.3 (1.3.3.3.4) 2011-12-07
* FIXED - lost of the PIN settings during the upgrade from fw version 1.3.0 and older
verze 1.4.0 (1.4.0.4.3) 2011-12-22
* AT API - access to the SmC Server from third-party applications
* time scheaduling of the firmware upgrade
* a few fixes
* upgrade of firmware from Terminal Config program over RS232 (Terminal Config
is not on the CD and the procedure is not explained in the manual)
version 1.5.0 (1.5.0.5.2) 2012-03-20
* UDF - user defined functions in SmC terminal - independent of the SmC Server
* import and export of the SmC Server database available to the user
* Access to the configuration port of SmC from SmC Server
* SmC Server code optimization - thousands of SmC terminals are supported over TCP
* Control Panel - a few fixes and improvements
* !!! FIXED problem of not-working on 850MHz and 1900MHz !!! Quadband is automatically activated
* Manual - upgrade of firmware from Terminal Config program over RS232 (already in 1.4.0, but
previously not explained in the manual)
2N SmartCom - Release Notes
20.3.2012
verze 1.3.3 (1.3.3.3.4) 2011-12-07
* FIXED - lost of the PIN settings during the upgrade from fw version 1.3.0 and older
verze 1.4.0 (1.4.0.4.3) 2011-12-22
* AT API - access to the SmC Server from third-party applications
* time scheaduling of the firmware upgrade
* a few fixes
* upgrade of firmware from Terminal Config program over RS232 (Terminal Config
is not on the CD and the procedure is not explained in the manual)
version 1.5.0 (1.5.0.5.2) 2012-03-20
* UDF - user defined functions in SmC terminal - independent of the SmC Server
* import and export of the SmC Server database available to the user
* Access to the configuration port of SmC from SmC Server
* SmC Server code optimization - thousands of SmC terminals are supported over TCP
* Control Panel - a few fixes and improvements
* !!! FIXED problem of not-working on 850MHz and 1900MHz !!! Quadband is automatically activated
* Manual - upgrade of firmware from Terminal Config program over RS232 (already in 1.4.0, but
previously not explained in the manual)
20.3.2012
verze 1.3.3 (1.3.3.3.4) 2011-12-07
* FIXED - lost of the PIN settings during the upgrade from fw version 1.3.0 and older
verze 1.4.0 (1.4.0.4.3) 2011-12-22
* AT API - access to the SmC Server from third-party applications
* time scheaduling of the firmware upgrade
* a few fixes
* upgrade of firmware from Terminal Config program over RS232 (Terminal Config
is not on the CD and the procedure is not explained in the manual)
version 1.5.0 (1.5.0.5.2) 2012-03-20
* UDF - user defined functions in SmC terminal - independent of the SmC Server
* import and export of the SmC Server database available to the user
* Access to the configuration port of SmC from SmC Server
* SmC Server code optimization - thousands of SmC terminals are supported over TCP
* Control Panel - a few fixes and improvements
* !!! FIXED problem of not-working on 850MHz and 1900MHz !!! Quadband is automatically activated
* Manual - upgrade of firmware from Terminal Config program over RS232 (already in 1.4.0, but
previously not explained in the manual)
New Features
1. SNMP protocol V2 and V3 support
2. Log files saved in Flash memory - accessible after restart.
3. Username a Password in menu WAN (PPPoE) length 63 characters
Fixed Bugs:
1. All characters in the APN name permitted (problem with ',')
2. Vendor OID corrected to 6530 (there was incorrect 6535)
3. Switching to backup route after FUP setting fixed
1. SNMP protocol V2 and V3 support
2. Log files saved in Flash memory - accessible after restart.
3. Username a Password in menu WAN (PPPoE) length 63 characters
Fixed Bugs:
1. All characters in the APN name permitted (problem with ',')
2. Vendor OID corrected to 6530 (there was incorrect 6535)
3. Switching to backup route after FUP setting fixed
New Features
1. SNMP protocol V2 and V3 support
2. Log files saved in Flash memory - accessible after restart.
3. Username a Password in menu WAN (PPPoE) length 63 characters
Fixed Bugs:
1. All characters in the APN name permitted (problem with ',')
2. Vendor OID corrected to 6530 (there was incorrect 6535)
3. Switching to backup route after FUP setting fixed
1. SNMP protocol V2 and V3 support
2. Log files saved in Flash memory - accessible after restart.
3. Username a Password in menu WAN (PPPoE) length 63 characters
Fixed Bugs:
1. All characters in the APN name permitted (problem with ',')
2. Vendor OID corrected to 6530 (there was incorrect 6535)
3. Switching to backup route after FUP setting fixed
New Features
1. SNMP protocol V2 and V3 support
2. Log files saved in Flash memory - accessible after restart.
3. Username a Password in menu WAN (PPPoE) length 63 characters
Fixed Bugs:
1. All characters in the APN name permitted (problem with ',')
2. Vendor OID corrected to 6530 (there was incorrect 6535)
3. Switching to backup route after FUP setting fixed
1. SNMP protocol V2 and V3 support
2. Log files saved in Flash memory - accessible after restart.
3. Username a Password in menu WAN (PPPoE) length 63 characters
Fixed Bugs:
1. All characters in the APN name permitted (problem with ',')
2. Vendor OID corrected to 6530 (there was incorrect 6535)
3. Switching to backup route after FUP setting fixed
2N® VoiceBlue Enterprise - Firmware
Release Notes
10.10.2011
VB3/VBE-2-3-16 2011-10-10
• SIP - DTMF transfer by SIP INFO method supported (set in the SIP line menu)
• CLIP Routing in LCR - call/SMS routed according to the calling party number
• Tarrifs - Weekly limit for calls/SMSs
• FIXED - Accounting files (CDRs) had 0 length after the new file has been created (on the 1st day of the month)
• FIXED - Network settings of UMTS modul not displayed correctly
• New UserGuide 1.8.2 (new features, LCR priority settings explained thoroughly!)
VB3/VBE-2-3-13 2011-03-09
• Firewall active on all interfaces (till now only on ethernet port) !!!
• Wizard deletes the SIP line for VoIP provider, if not used
• The maximal numbur od concurent calls could be set in the SIP line menu
• Incoming INVITE is ignored if the source IP address doesn't match to one set in SIP Server parameter of the SIP line
• U nově vložených SIM je defaultně zakázán roaming
• H.323 - StatusMsg supported
• FIXED - Network restriction has been checked in Cinterion modules only once, after the VBE switch-on
OFR/VB3/VBE-2-3-11 2010-11-12
• If a reboot of happens during receiving of a long SMS (divided in a few parts), all parts will be anyway concatenated
• Configuration restore - by default license in the device will not be rewritten
• SMSs in the Failed folder could be signed to be sent again
• Fixed – in LCR normalisation, the Caller incoming setting has been switched to Called outgoing when that record has been opened for editing again
• POP3 server - longer buffer for long SMSs
• Fixed – In the case of multi-part SMSs, normalisation has been done only for the first part
OFR/VB3/VBE-2-3-7 2010-05-17
• Concatenation of received SMSs
• Mobility Extension not only to GSM, but also to SIP lines
• SMS storage statistics
• Maximal DISA storage enlarged to 500kB
• !!! FIXED – one SMS could be sent, even i f it was set that no one could be !!!
• !!! FIXED - SMS-at-no-answer checkbox has been missing!!!
• PPPoE – Internet connection over ADSL modem or router in bridge mode
OFR/VB3/VBE-2-3-6 2010-02-21
• SMS at no answer
• „SIM card routing“ settings have been deleted from menu
• Restriction of receiving SMSs over certain GSM module
• !!! FIXED – the first GSM module could not be initialized !!!
• Long email, separated in a few SMSs, is presented as one SMS in the SENT folder
OFR/VB3/VBE-2-3-5 2009-12-23
• Backup of configuration contains only configuration folders
• Web interface – the lower left angle icons are unified in various menus
• XAPI 2.01J – fixed problem of firmware upgrade from the configuration tool, over port 1234
• PPP – significantly improved uplink data rate over UMTS module
• Web interface - improved response time
• Ring Groups - VoIP phones (extensions) could be rang together
• new default password of Admin is 2n
• DNS – fixed problem of cyclical rebooting of Ethernet module – It happened if DNS proxy was enabled and DNS servers haven’t been set
• SIP - header Diversion
• Fixed the problem with Sierra module – if RING has come during SMS sending, SMS was treated as not sent
• Voicemail – warning about almost filled up message space
OFR/VB3/VBE-2-3-2 2009-11-04
• DISA message – new settings – fall to the default operator, maximal duration of the voice mail message, improved voice quality of messages
• Listen port displayed in the SIP lines menu
• H.323 – the calling party identification in incomming calls- corrected
• QoS indication could be set for RTP and SIP
• Mobility Extension settings by SMS, service codes configurable from web interface
• SIP - headers P-Asserted-Identity and P-Preferred-Identity
• SIP – Value in the „Registration expires“ parameter is prioritized to the value in REGISTER confirmation (received from VoIP operator) if shorter than the later one. Otherwords, the shorter registration interval is prioritized.
• FIXED - AutoCLIP routing – comparing CLIP in the case of short numbers e.g. VPNs ( in the previous versions CLI had to have at least 6 digits to be matched )
• FIXED – USSD presentation in web interface
OFR/VB3/VBE-2-3-1 2009-09-23
• default IP address 192.168.1.1
• FIXED – analogue fax – empty anter to ATD caused erroneus bahaviour of device ( OFR only!)
OFR/VB3/VBE-2-3-0 2009-09-16
• DISA – interdigit timeout 4sec; cycling of the welcome message is limited – welcome message could be repeated three times. If there are no action from the calling party, the line is hanged up.
• all SMSs in folder could be deleted
• SMS – SMSs belonging to the same email are sent through the same module
• SMTP – faster authentication
• H.323 – new program modul, only one H.323 link supported (trunk)
Release Notes
10.10.2011
VB3/VBE-2-3-16 2011-10-10
• SIP - DTMF transfer by SIP INFO method supported (set in the SIP line menu)
• CLIP Routing in LCR - call/SMS routed according to the calling party number
• Tarrifs - Weekly limit for calls/SMSs
• FIXED - Accounting files (CDRs) had 0 length after the new file has been created (on the 1st day of the month)
• FIXED - Network settings of UMTS modul not displayed correctly
• New UserGuide 1.8.2 (new features, LCR priority settings explained thoroughly!)
VB3/VBE-2-3-13 2011-03-09
• Firewall active on all interfaces (till now only on ethernet port) !!!
• Wizard deletes the SIP line for VoIP provider, if not used
• The maximal numbur od concurent calls could be set in the SIP line menu
• Incoming INVITE is ignored if the source IP address doesn't match to one set in SIP Server parameter of the SIP line
• U nově vložených SIM je defaultně zakázán roaming
• H.323 - StatusMsg supported
• FIXED - Network restriction has been checked in Cinterion modules only once, after the VBE switch-on
OFR/VB3/VBE-2-3-11 2010-11-12
• If a reboot of happens during receiving of a long SMS (divided in a few parts), all parts will be anyway concatenated
• Configuration restore - by default license in the device will not be rewritten
• SMSs in the Failed folder could be signed to be sent again
• Fixed – in LCR normalisation, the Caller incoming setting has been switched to Called outgoing when that record has been opened for editing again
• POP3 server - longer buffer for long SMSs
• Fixed – In the case of multi-part SMSs, normalisation has been done only for the first part
OFR/VB3/VBE-2-3-7 2010-05-17
• Concatenation of received SMSs
• Mobility Extension not only to GSM, but also to SIP lines
• SMS storage statistics
• Maximal DISA storage enlarged to 500kB
• !!! FIXED – one SMS could be sent, even i f it was set that no one could be !!!
• !!! FIXED - SMS-at-no-answer checkbox has been missing!!!
• PPPoE – Internet connection over ADSL modem or router in bridge mode
OFR/VB3/VBE-2-3-6 2010-02-21
• SMS at no answer
• „SIM card routing“ settings have been deleted from menu
• Restriction of receiving SMSs over certain GSM module
• !!! FIXED – the first GSM module could not be initialized !!!
• Long email, separated in a few SMSs, is presented as one SMS in the SENT folder
OFR/VB3/VBE-2-3-5 2009-12-23
• Backup of configuration contains only configuration folders
• Web interface – the lower left angle icons are unified in various menus
• XAPI 2.01J – fixed problem of firmware upgrade from the configuration tool, over port 1234
• PPP – significantly improved uplink data rate over UMTS module
• Web interface - improved response time
• Ring Groups - VoIP phones (extensions) could be rang together
• new default password of Admin is 2n
• DNS – fixed problem of cyclical rebooting of Ethernet module – It happened if DNS proxy was enabled and DNS servers haven’t been set
• SIP - header Diversion
• Fixed the problem with Sierra module – if RING has come during SMS sending, SMS was treated as not sent
• Voicemail – warning about almost filled up message space
OFR/VB3/VBE-2-3-2 2009-11-04
• DISA message – new settings – fall to the default operator, maximal duration of the voice mail message, improved voice quality of messages
• Listen port displayed in the SIP lines menu
• H.323 – the calling party identification in incomming calls- corrected
• QoS indication could be set for RTP and SIP
• Mobility Extension settings by SMS, service codes configurable from web interface
• SIP - headers P-Asserted-Identity and P-Preferred-Identity
• SIP – Value in the „Registration expires“ parameter is prioritized to the value in REGISTER confirmation (received from VoIP operator) if shorter than the later one. Otherwords, the shorter registration interval is prioritized.
• FIXED - AutoCLIP routing – comparing CLIP in the case of short numbers e.g. VPNs ( in the previous versions CLI had to have at least 6 digits to be matched )
• FIXED – USSD presentation in web interface
OFR/VB3/VBE-2-3-1 2009-09-23
• default IP address 192.168.1.1
• FIXED – analogue fax – empty anter to ATD caused erroneus bahaviour of device ( OFR only!)
OFR/VB3/VBE-2-3-0 2009-09-16
• DISA – interdigit timeout 4sec; cycling of the welcome message is limited – welcome message could be repeated three times. If there are no action from the calling party, the line is hanged up.
• all SMSs in folder could be deleted
• SMS – SMSs belonging to the same email are sent through the same module
• SMTP – faster authentication
• H.323 – new program modul, only one H.323 link supported (trunk)
2N® VoiceBlue Enterprise - Firmware
Release Notes
10.10.2011
VB3/VBE-2-3-16 2011-10-10
• SIP - DTMF transfer by SIP INFO method supported (set in the SIP line menu)
• CLIP Routing in LCR - call/SMS routed according to the calling party number
• Tarrifs - Weekly limit for calls/SMSs
• FIXED - Accounting files (CDRs) had 0 length after the new file has been created (on the 1st day of the month)
• FIXED - Network settings of UMTS modul not displayed correctly
• New UserGuide 1.8.2 (new features, LCR priority settings explained thoroughly!)
VB3/VBE-2-3-13 2011-03-09
• Firewall active on all interfaces (till now only on ethernet port) !!!
• Wizard deletes the SIP line for VoIP provider, if not used
• The maximal numbur od concurent calls could be set in the SIP line menu
• Incoming INVITE is ignored if the source IP address doesn't match to one set in SIP Server parameter of the SIP line
• U nově vložených SIM je defaultně zakázán roaming
• H.323 - StatusMsg supported
• FIXED - Network restriction has been checked in Cinterion modules only once, after the VBE switch-on
OFR/VB3/VBE-2-3-11 2010-11-12
• If a reboot of happens during receiving of a long SMS (divided in a few parts), all parts will be anyway concatenated
• Configuration restore - by default license in the device will not be rewritten
• SMSs in the Failed folder could be signed to be sent again
• Fixed – in LCR normalisation, the Caller incoming setting has been switched to Called outgoing when that record has been opened for editing again
• POP3 server - longer buffer for long SMSs
• Fixed – In the case of multi-part SMSs, normalisation has been done only for the first part
OFR/VB3/VBE-2-3-7 2010-05-17
• Concatenation of received SMSs
• Mobility Extension not only to GSM, but also to SIP lines
• SMS storage statistics
• Maximal DISA storage enlarged to 500kB
• !!! FIXED – one SMS could be sent, even i f it was set that no one could be !!!
• !!! FIXED - SMS-at-no-answer checkbox has been missing!!!
• PPPoE – Internet connection over ADSL modem or router in bridge mode
OFR/VB3/VBE-2-3-6 2010-02-21
• SMS at no answer
• „SIM card routing“ settings have been deleted from menu
• Restriction of receiving SMSs over certain GSM module
• !!! FIXED – the first GSM module could not be initialized !!!
• Long email, separated in a few SMSs, is presented as one SMS in the SENT folder
OFR/VB3/VBE-2-3-5 2009-12-23
• Backup of configuration contains only configuration folders
• Web interface – the lower left angle icons are unified in various menus
• XAPI 2.01J – fixed problem of firmware upgrade from the configuration tool, over port 1234
• PPP – significantly improved uplink data rate over UMTS module
• Web interface - improved response time
• Ring Groups - VoIP phones (extensions) could be rang together
• new default password of Admin is 2n
• DNS – fixed problem of cyclical rebooting of Ethernet module – It happened if DNS proxy was enabled and DNS servers haven’t been set
• SIP - header Diversion
• Fixed the problem with Sierra module – if RING has come during SMS sending, SMS was treated as not sent
• Voicemail – warning about almost filled up message space
OFR/VB3/VBE-2-3-2 2009-11-04
• DISA message – new settings – fall to the default operator, maximal duration of the voice mail message, improved voice quality of messages
• Listen port displayed in the SIP lines menu
• H.323 – the calling party identification in incomming calls- corrected
• QoS indication could be set for RTP and SIP
• Mobility Extension settings by SMS, service codes configurable from web interface
• SIP - headers P-Asserted-Identity and P-Preferred-Identity
• SIP – Value in the „Registration expires“ parameter is prioritized to the value in REGISTER confirmation (received from VoIP operator) if shorter than the later one. Otherwords, the shorter registration interval is prioritized.
• FIXED - AutoCLIP routing – comparing CLIP in the case of short numbers e.g. VPNs ( in the previous versions CLI had to have at least 6 digits to be matched )
• FIXED – USSD presentation in web interface
OFR/VB3/VBE-2-3-1 2009-09-23
• default IP address 192.168.1.1
• FIXED – analogue fax – empty anter to ATD caused erroneus bahaviour of device ( OFR only!)
OFR/VB3/VBE-2-3-0 2009-09-16
• DISA – interdigit timeout 4sec; cycling of the welcome message is limited – welcome message could be repeated three times. If there are no action from the calling party, the line is hanged up.
• all SMSs in folder could be deleted
• SMS – SMSs belonging to the same email are sent through the same module
• SMTP – faster authentication
• H.323 – new program modul, only one H.323 link supported (trunk)
Release Notes
10.10.2011
VB3/VBE-2-3-16 2011-10-10
• SIP - DTMF transfer by SIP INFO method supported (set in the SIP line menu)
• CLIP Routing in LCR - call/SMS routed according to the calling party number
• Tarrifs - Weekly limit for calls/SMSs
• FIXED - Accounting files (CDRs) had 0 length after the new file has been created (on the 1st day of the month)
• FIXED - Network settings of UMTS modul not displayed correctly
• New UserGuide 1.8.2 (new features, LCR priority settings explained thoroughly!)
VB3/VBE-2-3-13 2011-03-09
• Firewall active on all interfaces (till now only on ethernet port) !!!
• Wizard deletes the SIP line for VoIP provider, if not used
• The maximal numbur od concurent calls could be set in the SIP line menu
• Incoming INVITE is ignored if the source IP address doesn't match to one set in SIP Server parameter of the SIP line
• U nově vložených SIM je defaultně zakázán roaming
• H.323 - StatusMsg supported
• FIXED - Network restriction has been checked in Cinterion modules only once, after the VBE switch-on
OFR/VB3/VBE-2-3-11 2010-11-12
• If a reboot of happens during receiving of a long SMS (divided in a few parts), all parts will be anyway concatenated
• Configuration restore - by default license in the device will not be rewritten
• SMSs in the Failed folder could be signed to be sent again
• Fixed – in LCR normalisation, the Caller incoming setting has been switched to Called outgoing when that record has been opened for editing again
• POP3 server - longer buffer for long SMSs
• Fixed – In the case of multi-part SMSs, normalisation has been done only for the first part
OFR/VB3/VBE-2-3-7 2010-05-17
• Concatenation of received SMSs
• Mobility Extension not only to GSM, but also to SIP lines
• SMS storage statistics
• Maximal DISA storage enlarged to 500kB
• !!! FIXED – one SMS could be sent, even i f it was set that no one could be !!!
• !!! FIXED - SMS-at-no-answer checkbox has been missing!!!
• PPPoE – Internet connection over ADSL modem or router in bridge mode
OFR/VB3/VBE-2-3-6 2010-02-21
• SMS at no answer
• „SIM card routing“ settings have been deleted from menu
• Restriction of receiving SMSs over certain GSM module
• !!! FIXED – the first GSM module could not be initialized !!!
• Long email, separated in a few SMSs, is presented as one SMS in the SENT folder
OFR/VB3/VBE-2-3-5 2009-12-23
• Backup of configuration contains only configuration folders
• Web interface – the lower left angle icons are unified in various menus
• XAPI 2.01J – fixed problem of firmware upgrade from the configuration tool, over port 1234
• PPP – significantly improved uplink data rate over UMTS module
• Web interface - improved response time
• Ring Groups - VoIP phones (extensions) could be rang together
• new default password of Admin is 2n
• DNS – fixed problem of cyclical rebooting of Ethernet module – It happened if DNS proxy was enabled and DNS servers haven’t been set
• SIP - header Diversion
• Fixed the problem with Sierra module – if RING has come during SMS sending, SMS was treated as not sent
• Voicemail – warning about almost filled up message space
OFR/VB3/VBE-2-3-2 2009-11-04
• DISA message – new settings – fall to the default operator, maximal duration of the voice mail message, improved voice quality of messages
• Listen port displayed in the SIP lines menu
• H.323 – the calling party identification in incomming calls- corrected
• QoS indication could be set for RTP and SIP
• Mobility Extension settings by SMS, service codes configurable from web interface
• SIP - headers P-Asserted-Identity and P-Preferred-Identity
• SIP – Value in the „Registration expires“ parameter is prioritized to the value in REGISTER confirmation (received from VoIP operator) if shorter than the later one. Otherwords, the shorter registration interval is prioritized.
• FIXED - AutoCLIP routing – comparing CLIP in the case of short numbers e.g. VPNs ( in the previous versions CLI had to have at least 6 digits to be matched )
• FIXED – USSD presentation in web interface
OFR/VB3/VBE-2-3-1 2009-09-23
• default IP address 192.168.1.1
• FIXED – analogue fax – empty anter to ATD caused erroneus bahaviour of device ( OFR only!)
OFR/VB3/VBE-2-3-0 2009-09-16
• DISA – interdigit timeout 4sec; cycling of the welcome message is limited – welcome message could be repeated three times. If there are no action from the calling party, the line is hanged up.
• all SMSs in folder could be deleted
• SMS – SMSs belonging to the same email are sent through the same module
• SMTP – faster authentication
• H.323 – new program modul, only one H.323 link supported (trunk)
2N® VoiceBlue Enterprise - Firmware
Release Notes
09.03.2011
VB3/VBE-2-3-13 2011-03-09
• Firewall active on all interfaces (till now only on ethernet port) !!!
• Wizard deletes the SIP line for VoIP provider, if not used
• The maximal numbur od concurent calls could be set in the SIP line menu
• Incoming INVITE is ignored if the source IP address doesn't match to one set in SIP Server parameter of the SIP line
• U nově vložených SIM je defaultně zakázán roaming
• H.323 - StatusMsg supported
• FIXED - Network restriction has been checked in Cinterion modules only once, after the OFR switch-on
OFR/VB3/VBE-2-3-11 2010-11-12
• If a reboot of happens during receiving of a long SMS (divided in a few parts), all parts will be anyway concatenated
• Configuration restore - by default license in the device will not be rewritten
• SMSs in the Failed folder could be signed to be sent again
• Fixed – in LCR normalisation, the Caller incoming setting has been switched to Called outgoing when that record has been opened for editing again
• POP3 server - longer buffer for long SMSs
• Fixed – In the case of multi-part SMSs, normalisation has been done only for the first part
OFR/VB3/VBE-2-3-7 2010-05-17
• Concatenation of received SMSs
• Mobility Extension not only to GSM, but also to SIP lines
• SMS storage statistics
• Maximal DISA storage enlarged to 500kB
• !!! FIXED – one SMS could be sent, even i f it was set that no one could be !!!
• !!! FIXED - SMS-at-no-answer checkbox has been missing!!!
• PPPoE – Internet connection over ADSL modem or router in bridge mode
OFR/VB3/VBE-2-3-6 2010-02-21
• SMS at no answer
• „SIM card routing“ settings have been deleted from menu
• Restriction of receiving SMSs over certain GSM module
• !!! FIXED – the first GSM module could not be initialized !!!
• Long email, separated in a few SMSs, is presented as one SMS in the SENT folder
OFR/VB3/VBE-2-3-5 2009-12-23
• Backup of configuration contains only configuration folders
• Web interface – the lower left angle icons are unified in various menus
• XAPI 2.01J – fixed problem of firmware upgrade from the configuration tool, over port 1234
• PPP – significantly improved uplink data rate over UMTS module
• Web interface - improved response time
• Ring Groups - VoIP phones (extensions) could be rang together
• new default password of Admin is 2n
• DNS – fixed problem of cyclical rebooting of Ethernet module – It happened if DNS proxy was enabled and DNS servers haven’t been set
• SIP - header Diversion
• Fixed the problem with Sierra module – if RING has come during SMS sending, SMS was treated as not sent
• Voicemail – warning about almost filled up message space
OFR/VB3/VBE-2-3-2 2009-11-04
• DISA message – new settings – fall to the default operator, maximal duration of the voice mail message, improved voice quality of messages
• Listen port displayed in the SIP lines menu
• H.323 – the calling party identification in incomming calls- corrected
• QoS indication could be set for RTP and SIP
• Mobility Extension settings by SMS, service codes configurable from web interface
• SIP - headers P-Asserted-Identity and P-Preferred-Identity
• SIP – Value in the „Registration expires“ parameter is prioritized to the value in REGISTER confirmation (received from VoIP operator) if shorter than the later one. Otherwords, the shorter registration interval is prioritized.
• FIXED - AutoCLIP routing – comparing CLIP in the case of short numbers e.g. VPNs ( in the previous versions CLI had to have at least 6 digits to be matched )
• FIXED – USSD presentation in web interface
OFR/VB3/VBE-2-3-1 2009-09-23
• default IP address 192.168.1.1
• FIXED – analogue fax – empty anter to ATD caused erroneus bahaviour of device ( OFR only!)
OFR/VB3/VBE-2-3-0 2009-09-16
• DISA – interdigit timeout 4sec; cycling of the welcome message is limited – welcome message could be repeated three times. If there are no action from the calling party, the line is hanged up.
• all SMSs in folder could be deleted
• SMS – SMSs belonging to the same email are sent through the same module
• SMTP – faster authentication
• H.323 – new program modul, only one H.323 link supported (trunk)
Release Notes
09.03.2011
VB3/VBE-2-3-13 2011-03-09
• Firewall active on all interfaces (till now only on ethernet port) !!!
• Wizard deletes the SIP line for VoIP provider, if not used
• The maximal numbur od concurent calls could be set in the SIP line menu
• Incoming INVITE is ignored if the source IP address doesn't match to one set in SIP Server parameter of the SIP line
• U nově vložených SIM je defaultně zakázán roaming
• H.323 - StatusMsg supported
• FIXED - Network restriction has been checked in Cinterion modules only once, after the OFR switch-on
OFR/VB3/VBE-2-3-11 2010-11-12
• If a reboot of happens during receiving of a long SMS (divided in a few parts), all parts will be anyway concatenated
• Configuration restore - by default license in the device will not be rewritten
• SMSs in the Failed folder could be signed to be sent again
• Fixed – in LCR normalisation, the Caller incoming setting has been switched to Called outgoing when that record has been opened for editing again
• POP3 server - longer buffer for long SMSs
• Fixed – In the case of multi-part SMSs, normalisation has been done only for the first part
OFR/VB3/VBE-2-3-7 2010-05-17
• Concatenation of received SMSs
• Mobility Extension not only to GSM, but also to SIP lines
• SMS storage statistics
• Maximal DISA storage enlarged to 500kB
• !!! FIXED – one SMS could be sent, even i f it was set that no one could be !!!
• !!! FIXED - SMS-at-no-answer checkbox has been missing!!!
• PPPoE – Internet connection over ADSL modem or router in bridge mode
OFR/VB3/VBE-2-3-6 2010-02-21
• SMS at no answer
• „SIM card routing“ settings have been deleted from menu
• Restriction of receiving SMSs over certain GSM module
• !!! FIXED – the first GSM module could not be initialized !!!
• Long email, separated in a few SMSs, is presented as one SMS in the SENT folder
OFR/VB3/VBE-2-3-5 2009-12-23
• Backup of configuration contains only configuration folders
• Web interface – the lower left angle icons are unified in various menus
• XAPI 2.01J – fixed problem of firmware upgrade from the configuration tool, over port 1234
• PPP – significantly improved uplink data rate over UMTS module
• Web interface - improved response time
• Ring Groups - VoIP phones (extensions) could be rang together
• new default password of Admin is 2n
• DNS – fixed problem of cyclical rebooting of Ethernet module – It happened if DNS proxy was enabled and DNS servers haven’t been set
• SIP - header Diversion
• Fixed the problem with Sierra module – if RING has come during SMS sending, SMS was treated as not sent
• Voicemail – warning about almost filled up message space
OFR/VB3/VBE-2-3-2 2009-11-04
• DISA message – new settings – fall to the default operator, maximal duration of the voice mail message, improved voice quality of messages
• Listen port displayed in the SIP lines menu
• H.323 – the calling party identification in incomming calls- corrected
• QoS indication could be set for RTP and SIP
• Mobility Extension settings by SMS, service codes configurable from web interface
• SIP - headers P-Asserted-Identity and P-Preferred-Identity
• SIP – Value in the „Registration expires“ parameter is prioritized to the value in REGISTER confirmation (received from VoIP operator) if shorter than the later one. Otherwords, the shorter registration interval is prioritized.
• FIXED - AutoCLIP routing – comparing CLIP in the case of short numbers e.g. VPNs ( in the previous versions CLI had to have at least 6 digits to be matched )
• FIXED – USSD presentation in web interface
OFR/VB3/VBE-2-3-1 2009-09-23
• default IP address 192.168.1.1
• FIXED – analogue fax – empty anter to ATD caused erroneus bahaviour of device ( OFR only!)
OFR/VB3/VBE-2-3-0 2009-09-16
• DISA – interdigit timeout 4sec; cycling of the welcome message is limited – welcome message could be repeated three times. If there are no action from the calling party, the line is hanged up.
• all SMSs in folder could be deleted
• SMS – SMSs belonging to the same email are sent through the same module
• SMTP – faster authentication
• H.323 – new program modul, only one H.323 link supported (trunk)
2N® VoiceBlue Enterprise - Firmware
Release Notes
09.03.2011
VB3/VBE-2-3-13 2011-03-09
• Firewall active on all interfaces (till now only on ethernet port) !!!
• Wizard deletes the SIP line for VoIP provider, if not used
• The maximal numbur od concurent calls could be set in the SIP line menu
• Incoming INVITE is ignored if the source IP address doesn't match to one set in SIP Server parameter of the SIP line
• U nově vložených SIM je defaultně zakázán roaming
• H.323 - StatusMsg supported
• FIXED - Network restriction has been checked in Cinterion modules only once, after the OFR switch-on
OFR/VB3/VBE-2-3-11 2010-11-12
• If a reboot of happens during receiving of a long SMS (divided in a few parts), all parts will be anyway concatenated
• Configuration restore - by default license in the device will not be rewritten
• SMSs in the Failed folder could be signed to be sent again
• Fixed – in LCR normalisation, the Caller incoming setting has been switched to Called outgoing when that record has been opened for editing again
• POP3 server - longer buffer for long SMSs
• Fixed – In the case of multi-part SMSs, normalisation has been done only for the first part
OFR/VB3/VBE-2-3-7 2010-05-17
• Concatenation of received SMSs
• Mobility Extension not only to GSM, but also to SIP lines
• SMS storage statistics
• Maximal DISA storage enlarged to 500kB
• !!! FIXED – one SMS could be sent, even i f it was set that no one could be !!!
• !!! FIXED - SMS-at-no-answer checkbox has been missing!!!
• PPPoE – Internet connection over ADSL modem or router in bridge mode
OFR/VB3/VBE-2-3-6 2010-02-21
• SMS at no answer
• „SIM card routing“ settings have been deleted from menu
• Restriction of receiving SMSs over certain GSM module
• !!! FIXED – the first GSM module could not be initialized !!!
• Long email, separated in a few SMSs, is presented as one SMS in the SENT folder
OFR/VB3/VBE-2-3-5 2009-12-23
• Backup of configuration contains only configuration folders
• Web interface – the lower left angle icons are unified in various menus
• XAPI 2.01J – fixed problem of firmware upgrade from the configuration tool, over port 1234
• PPP – significantly improved uplink data rate over UMTS module
• Web interface - improved response time
• Ring Groups - VoIP phones (extensions) could be rang together
• new default password of Admin is 2n
• DNS – fixed problem of cyclical rebooting of Ethernet module – It happened if DNS proxy was enabled and DNS servers haven’t been set
• SIP - header Diversion
• Fixed the problem with Sierra module – if RING has come during SMS sending, SMS was treated as not sent
• Voicemail – warning about almost filled up message space
OFR/VB3/VBE-2-3-2 2009-11-04
• DISA message – new settings – fall to the default operator, maximal duration of the voice mail message, improved voice quality of messages
• Listen port displayed in the SIP lines menu
• H.323 – the calling party identification in incomming calls- corrected
• QoS indication could be set for RTP and SIP
• Mobility Extension settings by SMS, service codes configurable from web interface
• SIP - headers P-Asserted-Identity and P-Preferred-Identity
• SIP – Value in the „Registration expires“ parameter is prioritized to the value in REGISTER confirmation (received from VoIP operator) if shorter than the later one. Otherwords, the shorter registration interval is prioritized.
• FIXED - AutoCLIP routing – comparing CLIP in the case of short numbers e.g. VPNs ( in the previous versions CLI had to have at least 6 digits to be matched )
• FIXED – USSD presentation in web interface
OFR/VB3/VBE-2-3-1 2009-09-23
• default IP address 192.168.1.1
• FIXED – analogue fax – empty anter to ATD caused erroneus bahaviour of device ( OFR only!)
OFR/VB3/VBE-2-3-0 2009-09-16
• DISA – interdigit timeout 4sec; cycling of the welcome message is limited – welcome message could be repeated three times. If there are no action from the calling party, the line is hanged up.
• all SMSs in folder could be deleted
• SMS – SMSs belonging to the same email are sent through the same module
• SMTP – faster authentication
• H.323 – new program modul, only one H.323 link supported (trunk)
Release Notes
09.03.2011
VB3/VBE-2-3-13 2011-03-09
• Firewall active on all interfaces (till now only on ethernet port) !!!
• Wizard deletes the SIP line for VoIP provider, if not used
• The maximal numbur od concurent calls could be set in the SIP line menu
• Incoming INVITE is ignored if the source IP address doesn't match to one set in SIP Server parameter of the SIP line
• U nově vložených SIM je defaultně zakázán roaming
• H.323 - StatusMsg supported
• FIXED - Network restriction has been checked in Cinterion modules only once, after the OFR switch-on
OFR/VB3/VBE-2-3-11 2010-11-12
• If a reboot of happens during receiving of a long SMS (divided in a few parts), all parts will be anyway concatenated
• Configuration restore - by default license in the device will not be rewritten
• SMSs in the Failed folder could be signed to be sent again
• Fixed – in LCR normalisation, the Caller incoming setting has been switched to Called outgoing when that record has been opened for editing again
• POP3 server - longer buffer for long SMSs
• Fixed – In the case of multi-part SMSs, normalisation has been done only for the first part
OFR/VB3/VBE-2-3-7 2010-05-17
• Concatenation of received SMSs
• Mobility Extension not only to GSM, but also to SIP lines
• SMS storage statistics
• Maximal DISA storage enlarged to 500kB
• !!! FIXED – one SMS could be sent, even i f it was set that no one could be !!!
• !!! FIXED - SMS-at-no-answer checkbox has been missing!!!
• PPPoE – Internet connection over ADSL modem or router in bridge mode
OFR/VB3/VBE-2-3-6 2010-02-21
• SMS at no answer
• „SIM card routing“ settings have been deleted from menu
• Restriction of receiving SMSs over certain GSM module
• !!! FIXED – the first GSM module could not be initialized !!!
• Long email, separated in a few SMSs, is presented as one SMS in the SENT folder
OFR/VB3/VBE-2-3-5 2009-12-23
• Backup of configuration contains only configuration folders
• Web interface – the lower left angle icons are unified in various menus
• XAPI 2.01J – fixed problem of firmware upgrade from the configuration tool, over port 1234
• PPP – significantly improved uplink data rate over UMTS module
• Web interface - improved response time
• Ring Groups - VoIP phones (extensions) could be rang together
• new default password of Admin is 2n
• DNS – fixed problem of cyclical rebooting of Ethernet module – It happened if DNS proxy was enabled and DNS servers haven’t been set
• SIP - header Diversion
• Fixed the problem with Sierra module – if RING has come during SMS sending, SMS was treated as not sent
• Voicemail – warning about almost filled up message space
OFR/VB3/VBE-2-3-2 2009-11-04
• DISA message – new settings – fall to the default operator, maximal duration of the voice mail message, improved voice quality of messages
• Listen port displayed in the SIP lines menu
• H.323 – the calling party identification in incomming calls- corrected
• QoS indication could be set for RTP and SIP
• Mobility Extension settings by SMS, service codes configurable from web interface
• SIP - headers P-Asserted-Identity and P-Preferred-Identity
• SIP – Value in the „Registration expires“ parameter is prioritized to the value in REGISTER confirmation (received from VoIP operator) if shorter than the later one. Otherwords, the shorter registration interval is prioritized.
• FIXED - AutoCLIP routing – comparing CLIP in the case of short numbers e.g. VPNs ( in the previous versions CLI had to have at least 6 digits to be matched )
• FIXED – USSD presentation in web interface
OFR/VB3/VBE-2-3-1 2009-09-23
• default IP address 192.168.1.1
• FIXED – analogue fax – empty anter to ATD caused erroneus bahaviour of device ( OFR only!)
OFR/VB3/VBE-2-3-0 2009-09-16
• DISA – interdigit timeout 4sec; cycling of the welcome message is limited – welcome message could be repeated three times. If there are no action from the calling party, the line is hanged up.
• all SMSs in folder could be deleted
• SMS – SMSs belonging to the same email are sent through the same module
• SMTP – faster authentication
• H.323 – new program modul, only one H.323 link supported (trunk)
2N® VoiceBlue Enterprise - Firmware
Release Notes
12.11.2010
OFR/VB3/VBE-2-3-11 2010-11-12
• If a reboot of happens during receiving of a long SMS (divided in a few parts), all parts will be anyway concatenated
• Configuration restore - by default license in the device will not be rewritten
• SMSs in the Failed folder could be signed to be sent again
• Fixed – in LCR normalisation, the Caller incoming setting has been switched to Called outgoing when that record has been opened for editing again
• POP3 server - longer buffer for long SMSs
• Fixed – In the case of multi-part SMSs, normalisation has been done only for the first part
OFR/VB3/VBE-2-3-7 2010-05-17
• Concatenation of received SMSs
• Mobility Extension not only to GSM, but also to SIP lines
• SMS storage statistics
• Maximal DISA storage enlarged to 500kB
• !!! FIXED – one SMS could be sent, even i f it was set that no one could be !!!
• !!! FIXED - SMS-at-no-answer checkbox has been missing!!!
• PPPoE – Internet connection over ADSL modem or router in bridge mode
OFR/VB3/VBE-2-3-6 2010-02-21
• SMS at no answer
• „SIM card routing“ settings have been deleted from menu
• Restriction of receiving SMSs over certain GSM module
• !!! FIXED – the first GSM module could not be initialized !!!
• Long email, separated in a few SMSs, is presented as one SMS in the SENT folder
OFR/VB3/VBE-2-3-5 2009-12-23
• Backup of configuration contains only configuration folders
• Web interface – the lower left angle icons are unified in various menus
• XAPI 2.01J – fixed problem of firmware upgrade from the configuration tool, over port 1234
• PPP – significantly improved uplink data rate over UMTS module
• Web interface - improved response time
• Ring Groups - VoIP phones (extensions) could be rang together
• new default password of Admin is 2n
• DNS – fixed problem of cyclical rebooting of Ethernet module – It happened if DNS proxy was enabled and DNS servers haven’t been set
• SIP - header Diversion
• Fixed the problem with Sierra module – if RING has come during SMS sending, SMS was treated as not sent
• Voicemail – warning about almost filled up message space
OFR/VB3/VBE-2-3-2 2009-11-04
• DISA message – new settings – fall to the default operator, maximal duration of the voice mail message, improved voice quality of messages
• Listen port displayed in the SIP lines menu
• H.323 – the calling party identification in incomming calls- corrected
• QoS indication could be set for RTP and SIP
• Mobility Extension settings by SMS, service codes configurable from web interface
• SIP - headers P-Asserted-Identity and P-Preferred-Identity
• SIP – Value in the „Registration expires“ parameter is prioritized to the value in REGISTER confirmation (received from VoIP operator) if shorter than the later one. Otherwords, the shorter registration interval is prioritized.
• FIXED - AutoCLIP routing – comparing CLIP in the case of short numbers e.g. VPNs ( in the previous versions CLI had to have at least 6 digits to be matched )
• FIXED – USSD presentation in web interface
OFR/VB3/VBE-2-3-1 2009-09-23
• default IP address 192.168.1.1
• FIXED – analogue fax – empty anter to ATD caused erroneus bahaviour of device ( OFR only!)
OFR/VB3/VBE-2-3-0 2009-09-16
• DISA – interdigit timeout 4sec; cycling of the welcome message is limited – welcome message could be repeated three times. If there are no action from the calling party, the line is hanged up.
• all SMSs in folder could be deleted
• SMS – SMSs belonging to the same email are sent through the same module
• SMTP – faster authentication
• H.323 – new program modul, only one H.323 link supported (trunk)
Release Notes
12.11.2010
OFR/VB3/VBE-2-3-11 2010-11-12
• If a reboot of happens during receiving of a long SMS (divided in a few parts), all parts will be anyway concatenated
• Configuration restore - by default license in the device will not be rewritten
• SMSs in the Failed folder could be signed to be sent again
• Fixed – in LCR normalisation, the Caller incoming setting has been switched to Called outgoing when that record has been opened for editing again
• POP3 server - longer buffer for long SMSs
• Fixed – In the case of multi-part SMSs, normalisation has been done only for the first part
OFR/VB3/VBE-2-3-7 2010-05-17
• Concatenation of received SMSs
• Mobility Extension not only to GSM, but also to SIP lines
• SMS storage statistics
• Maximal DISA storage enlarged to 500kB
• !!! FIXED – one SMS could be sent, even i f it was set that no one could be !!!
• !!! FIXED - SMS-at-no-answer checkbox has been missing!!!
• PPPoE – Internet connection over ADSL modem or router in bridge mode
OFR/VB3/VBE-2-3-6 2010-02-21
• SMS at no answer
• „SIM card routing“ settings have been deleted from menu
• Restriction of receiving SMSs over certain GSM module
• !!! FIXED – the first GSM module could not be initialized !!!
• Long email, separated in a few SMSs, is presented as one SMS in the SENT folder
OFR/VB3/VBE-2-3-5 2009-12-23
• Backup of configuration contains only configuration folders
• Web interface – the lower left angle icons are unified in various menus
• XAPI 2.01J – fixed problem of firmware upgrade from the configuration tool, over port 1234
• PPP – significantly improved uplink data rate over UMTS module
• Web interface - improved response time
• Ring Groups - VoIP phones (extensions) could be rang together
• new default password of Admin is 2n
• DNS – fixed problem of cyclical rebooting of Ethernet module – It happened if DNS proxy was enabled and DNS servers haven’t been set
• SIP - header Diversion
• Fixed the problem with Sierra module – if RING has come during SMS sending, SMS was treated as not sent
• Voicemail – warning about almost filled up message space
OFR/VB3/VBE-2-3-2 2009-11-04
• DISA message – new settings – fall to the default operator, maximal duration of the voice mail message, improved voice quality of messages
• Listen port displayed in the SIP lines menu
• H.323 – the calling party identification in incomming calls- corrected
• QoS indication could be set for RTP and SIP
• Mobility Extension settings by SMS, service codes configurable from web interface
• SIP - headers P-Asserted-Identity and P-Preferred-Identity
• SIP – Value in the „Registration expires“ parameter is prioritized to the value in REGISTER confirmation (received from VoIP operator) if shorter than the later one. Otherwords, the shorter registration interval is prioritized.
• FIXED - AutoCLIP routing – comparing CLIP in the case of short numbers e.g. VPNs ( in the previous versions CLI had to have at least 6 digits to be matched )
• FIXED – USSD presentation in web interface
OFR/VB3/VBE-2-3-1 2009-09-23
• default IP address 192.168.1.1
• FIXED – analogue fax – empty anter to ATD caused erroneus bahaviour of device ( OFR only!)
OFR/VB3/VBE-2-3-0 2009-09-16
• DISA – interdigit timeout 4sec; cycling of the welcome message is limited – welcome message could be repeated three times. If there are no action from the calling party, the line is hanged up.
• all SMSs in folder could be deleted
• SMS – SMSs belonging to the same email are sent through the same module
• SMTP – faster authentication
• H.323 – new program modul, only one H.323 link supported (trunk)
2N® VoiceBlue Enterprise - Firmware
Release Notes
12.11.2010
OFR/VB3/VBE-2-3-11 2010-11-12
• If a reboot of happens during receiving of a long SMS (divided in a few parts), all parts will be anyway concatenated
• Configuration restore - by default license in the device will not be rewritten
• SMSs in the Failed folder could be signed to be sent again
• Fixed – in LCR normalisation, the Caller incoming setting has been switched to Called outgoing when that record has been opened for editing again
• POP3 server - longer buffer for long SMSs
• Fixed – In the case of multi-part SMSs, normalisation has been done only for the first part
OFR/VB3/VBE-2-3-7 2010-05-17
• Concatenation of received SMSs
• Mobility Extension not only to GSM, but also to SIP lines
• SMS storage statistics
• Maximal DISA storage enlarged to 500kB
• !!! FIXED – one SMS could be sent, even i f it was set that no one could be !!!
• !!! FIXED - SMS-at-no-answer checkbox has been missing!!!
• PPPoE – Internet connection over ADSL modem or router in bridge mode
OFR/VB3/VBE-2-3-6 2010-02-21
• SMS at no answer
• „SIM card routing“ settings have been deleted from menu
• Restriction of receiving SMSs over certain GSM module
• !!! FIXED – the first GSM module could not be initialized !!!
• Long email, separated in a few SMSs, is presented as one SMS in the SENT folder
OFR/VB3/VBE-2-3-5 2009-12-23
• Backup of configuration contains only configuration folders
• Web interface – the lower left angle icons are unified in various menus
• XAPI 2.01J – fixed problem of firmware upgrade from the configuration tool, over port 1234
• PPP – significantly improved uplink data rate over UMTS module
• Web interface - improved response time
• Ring Groups - VoIP phones (extensions) could be rang together
• new default password of Admin is 2n
• DNS – fixed problem of cyclical rebooting of Ethernet module – It happened if DNS proxy was enabled and DNS servers haven’t been set
• SIP - header Diversion
• Fixed the problem with Sierra module – if RING has come during SMS sending, SMS was treated as not sent
• Voicemail – warning about almost filled up message space
OFR/VB3/VBE-2-3-2 2009-11-04
• DISA message – new settings – fall to the default operator, maximal duration of the voice mail message, improved voice quality of messages
• Listen port displayed in the SIP lines menu
• H.323 – the calling party identification in incomming calls- corrected
• QoS indication could be set for RTP and SIP
• Mobility Extension settings by SMS, service codes configurable from web interface
• SIP - headers P-Asserted-Identity and P-Preferred-Identity
• SIP – Value in the „Registration expires“ parameter is prioritized to the value in REGISTER confirmation (received from VoIP operator) if shorter than the later one. Otherwords, the shorter registration interval is prioritized.
• FIXED - AutoCLIP routing – comparing CLIP in the case of short numbers e.g. VPNs ( in the previous versions CLI had to have at least 6 digits to be matched )
• FIXED – USSD presentation in web interface
OFR/VB3/VBE-2-3-1 2009-09-23
• default IP address 192.168.1.1
• FIXED – analogue fax – empty anter to ATD caused erroneus bahaviour of device ( OFR only!)
OFR/VB3/VBE-2-3-0 2009-09-16
• DISA – interdigit timeout 4sec; cycling of the welcome message is limited – welcome message could be repeated three times. If there are no action from the calling party, the line is hanged up.
• all SMSs in folder could be deleted
• SMS – SMSs belonging to the same email are sent through the same module
• SMTP – faster authentication
• H.323 – new program modul, only one H.323 link supported (trunk)
Release Notes
12.11.2010
OFR/VB3/VBE-2-3-11 2010-11-12
• If a reboot of happens during receiving of a long SMS (divided in a few parts), all parts will be anyway concatenated
• Configuration restore - by default license in the device will not be rewritten
• SMSs in the Failed folder could be signed to be sent again
• Fixed – in LCR normalisation, the Caller incoming setting has been switched to Called outgoing when that record has been opened for editing again
• POP3 server - longer buffer for long SMSs
• Fixed – In the case of multi-part SMSs, normalisation has been done only for the first part
OFR/VB3/VBE-2-3-7 2010-05-17
• Concatenation of received SMSs
• Mobility Extension not only to GSM, but also to SIP lines
• SMS storage statistics
• Maximal DISA storage enlarged to 500kB
• !!! FIXED – one SMS could be sent, even i f it was set that no one could be !!!
• !!! FIXED - SMS-at-no-answer checkbox has been missing!!!
• PPPoE – Internet connection over ADSL modem or router in bridge mode
OFR/VB3/VBE-2-3-6 2010-02-21
• SMS at no answer
• „SIM card routing“ settings have been deleted from menu
• Restriction of receiving SMSs over certain GSM module
• !!! FIXED – the first GSM module could not be initialized !!!
• Long email, separated in a few SMSs, is presented as one SMS in the SENT folder
OFR/VB3/VBE-2-3-5 2009-12-23
• Backup of configuration contains only configuration folders
• Web interface – the lower left angle icons are unified in various menus
• XAPI 2.01J – fixed problem of firmware upgrade from the configuration tool, over port 1234
• PPP – significantly improved uplink data rate over UMTS module
• Web interface - improved response time
• Ring Groups - VoIP phones (extensions) could be rang together
• new default password of Admin is 2n
• DNS – fixed problem of cyclical rebooting of Ethernet module – It happened if DNS proxy was enabled and DNS servers haven’t been set
• SIP - header Diversion
• Fixed the problem with Sierra module – if RING has come during SMS sending, SMS was treated as not sent
• Voicemail – warning about almost filled up message space
OFR/VB3/VBE-2-3-2 2009-11-04
• DISA message – new settings – fall to the default operator, maximal duration of the voice mail message, improved voice quality of messages
• Listen port displayed in the SIP lines menu
• H.323 – the calling party identification in incomming calls- corrected
• QoS indication could be set for RTP and SIP
• Mobility Extension settings by SMS, service codes configurable from web interface
• SIP - headers P-Asserted-Identity and P-Preferred-Identity
• SIP – Value in the „Registration expires“ parameter is prioritized to the value in REGISTER confirmation (received from VoIP operator) if shorter than the later one. Otherwords, the shorter registration interval is prioritized.
• FIXED - AutoCLIP routing – comparing CLIP in the case of short numbers e.g. VPNs ( in the previous versions CLI had to have at least 6 digits to be matched )
• FIXED – USSD presentation in web interface
OFR/VB3/VBE-2-3-1 2009-09-23
• default IP address 192.168.1.1
• FIXED – analogue fax – empty anter to ATD caused erroneus bahaviour of device ( OFR only!)
OFR/VB3/VBE-2-3-0 2009-09-16
• DISA – interdigit timeout 4sec; cycling of the welcome message is limited – welcome message could be repeated three times. If there are no action from the calling party, the line is hanged up.
• all SMSs in folder could be deleted
• SMS – SMSs belonging to the same email are sent through the same module
• SMTP – faster authentication
• H.323 – new program modul, only one H.323 link supported (trunk)
2N® VoiceBlue Enterprise - Firmware
Release Notes
17.05.2010
OFR/VB3/VBE-2-3-7 2010-05-17
• Concatenation of received SMSs
• Mobility Extension not only to GSM, but also to SIP lines
• SMS storage statistics
• Maximal DISA storage enlarged to 500kB
• !!! FIXED – one SMS could be sent, even i f it was set that no one could be !!!
• !!! FIXED - SMS-at-no-answer checkbox has been missing!!!
• PPPoE – Internet connection over ADSL modem or router in bridge mode
OFR/VB3/VBE-2-3-6 2010-02-21
• SMS at no answer
• „SIM card routing“ settings have been deleted from menu
• Restriction of receiving SMSs over certain GSM module
• !!! FIXED – the first GSM module could not be initialized !!!
• Long email, separated in a few SMSs, is presented as one SMS in the SENT folder
OFR/VB3/VBE-2-3-5 2009-12-23
• Backup of configuration contains only configuration folders
• Web interface – the lower left angle icons are unified in various menus
• XAPI 2.01J – fixed problem of firmware upgrade from the configuration tool, over
port 1234
• PPP – significantly improved uplink data rate over UMTS module
• Web interface - improved response time
• Ring Groups - VoIP phones (extensions) could be rang together
• new default password of Admin is 2n
• DNS – fixed problem of cyclical rebooting of Ethernet module – It happened if DNS
proxy was enabled and DNS servers haven’t been set
• SIP - header Diversion
• Fixed the problem with Sierra module – if RING has come during SMS sending, SMS was
treated as not sent
• Voicemail – warning about almost filled up message space
OFR/VB3/VBE-2-3-2 2009-11-04
• DISA message – new settings – fall to the default operator, maximal duration of
the voice mail message, improved voice quality of messages
• Listen port displayed in the SIP lines menu
• H.323 – the calling party identification in incomming calls- corrected
• QoS indication could be set for RTP and SIP
• Mobility Extension settings by SMS, service codes configurable from web interface
• SIP - headers P-Asserted-Identity and P-Preferred-Identity
• SIP – Value in the „Registration expires“ parameter is prioritized to the value in
REGISTER confirmation (received from VoIP operator) if shorter than the later one.
Otherwords, the shorter registration interval is prioritized.
• FIXED - AutoCLIP routing – comparing CLIP in the case of short numbers e.g. VPNs (
in the previous versions CLI had to have at least 6 digits to be matched )
• FIXED – USSD presentation in web interface
OFR/VB3/VBE-2-3-1 2009-09-23
• default IP address 192.168.1.1
• FIXED – analogue fax – empty anter to ATD caused erroneus bahaviour of device ( OFR
only!)
OFR/VB3/VBE-2-3-0 2009-09-16
• DISA – interdigit timeout 4sec; cycling of the welcome message is limited – welcome
message could be repeated three times. If there are no action from the calling party, the
line is hanged up.
• all SMSs in folder could be deleted
• SMS – SMSs belonging to the same email are sent through the same module
• SMTP – faster authentication
• H.323 – new program modul, only one H.323 link supported (trunk)
Release Notes
17.05.2010
OFR/VB3/VBE-2-3-7 2010-05-17
• Concatenation of received SMSs
• Mobility Extension not only to GSM, but also to SIP lines
• SMS storage statistics
• Maximal DISA storage enlarged to 500kB
• !!! FIXED – one SMS could be sent, even i f it was set that no one could be !!!
• !!! FIXED - SMS-at-no-answer checkbox has been missing!!!
• PPPoE – Internet connection over ADSL modem or router in bridge mode
OFR/VB3/VBE-2-3-6 2010-02-21
• SMS at no answer
• „SIM card routing“ settings have been deleted from menu
• Restriction of receiving SMSs over certain GSM module
• !!! FIXED – the first GSM module could not be initialized !!!
• Long email, separated in a few SMSs, is presented as one SMS in the SENT folder
OFR/VB3/VBE-2-3-5 2009-12-23
• Backup of configuration contains only configuration folders
• Web interface – the lower left angle icons are unified in various menus
• XAPI 2.01J – fixed problem of firmware upgrade from the configuration tool, over
port 1234
• PPP – significantly improved uplink data rate over UMTS module
• Web interface - improved response time
• Ring Groups - VoIP phones (extensions) could be rang together
• new default password of Admin is 2n
• DNS – fixed problem of cyclical rebooting of Ethernet module – It happened if DNS
proxy was enabled and DNS servers haven’t been set
• SIP - header Diversion
• Fixed the problem with Sierra module – if RING has come during SMS sending, SMS was
treated as not sent
• Voicemail – warning about almost filled up message space
OFR/VB3/VBE-2-3-2 2009-11-04
• DISA message – new settings – fall to the default operator, maximal duration of
the voice mail message, improved voice quality of messages
• Listen port displayed in the SIP lines menu
• H.323 – the calling party identification in incomming calls- corrected
• QoS indication could be set for RTP and SIP
• Mobility Extension settings by SMS, service codes configurable from web interface
• SIP - headers P-Asserted-Identity and P-Preferred-Identity
• SIP – Value in the „Registration expires“ parameter is prioritized to the value in
REGISTER confirmation (received from VoIP operator) if shorter than the later one.
Otherwords, the shorter registration interval is prioritized.
• FIXED - AutoCLIP routing – comparing CLIP in the case of short numbers e.g. VPNs (
in the previous versions CLI had to have at least 6 digits to be matched )
• FIXED – USSD presentation in web interface
OFR/VB3/VBE-2-3-1 2009-09-23
• default IP address 192.168.1.1
• FIXED – analogue fax – empty anter to ATD caused erroneus bahaviour of device ( OFR
only!)
OFR/VB3/VBE-2-3-0 2009-09-16
• DISA – interdigit timeout 4sec; cycling of the welcome message is limited – welcome
message could be repeated three times. If there are no action from the calling party, the
line is hanged up.
• all SMSs in folder could be deleted
• SMS – SMSs belonging to the same email are sent through the same module
• SMTP – faster authentication
• H.323 – new program modul, only one H.323 link supported (trunk)
2N® VoiceBlue Enterprise - Firmware
Release Notes
17.05.2010
OFR/VB3/VBE-2-3-7 2010-05-17
• Concatenation of received SMSs
• Mobility Extension not only to GSM, but also to SIP lines
• SMS storage statistics
• Maximal DISA storage enlarged to 500kB
• !!! FIXED – one SMS could be sent, even i f it was set that no one could be !!!
• !!! FIXED - SMS-at-no-answer checkbox has been missing!!!
• PPPoE – Internet connection over ADSL modem or router in bridge mode
OFR/VB3/VBE-2-3-6 2010-02-21
• SMS at no answer
• „SIM card routing“ settings have been deleted from menu
• Restriction of receiving SMSs over certain GSM module
• !!! FIXED – the first GSM module could not be initialized !!!
• Long email, separated in a few SMSs, is presented as one SMS in the SENT folder
OFR/VB3/VBE-2-3-5 2009-12-23
• Backup of configuration contains only configuration folders
• Web interface – the lower left angle icons are unified in various menus
• XAPI 2.01J – fixed problem of firmware upgrade from the configuration tool, over
port 1234
• PPP – significantly improved uplink data rate over UMTS module
• Web interface - improved response time
• Ring Groups - VoIP phones (extensions) could be rang together
• new default password of Admin is 2n
• DNS – fixed problem of cyclical rebooting of Ethernet module – It happened if DNS
proxy was enabled and DNS servers haven’t been set
• SIP - header Diversion
• Fixed the problem with Sierra module – if RING has come during SMS sending, SMS was
treated as not sent
• Voicemail – warning about almost filled up message space
OFR/VB3/VBE-2-3-2 2009-11-04
• DISA message – new settings – fall to the default operator, maximal duration of
the voice mail message, improved voice quality of messages
• Listen port displayed in the SIP lines menu
•
Release Notes
17.05.2010
OFR/VB3/VBE-2-3-7 2010-05-17
• Concatenation of received SMSs
• Mobility Extension not only to GSM, but also to SIP lines
• SMS storage statistics
• Maximal DISA storage enlarged to 500kB
• !!! FIXED – one SMS could be sent, even i f it was set that no one could be !!!
• !!! FIXED - SMS-at-no-answer checkbox has been missing!!!
• PPPoE – Internet connection over ADSL modem or router in bridge mode
OFR/VB3/VBE-2-3-6 2010-02-21
• SMS at no answer
• „SIM card routing“ settings have been deleted from menu
• Restriction of receiving SMSs over certain GSM module
• !!! FIXED – the first GSM module could not be initialized !!!
• Long email, separated in a few SMSs, is presented as one SMS in the SENT folder
OFR/VB3/VBE-2-3-5 2009-12-23
• Backup of configuration contains only configuration folders
• Web interface – the lower left angle icons are unified in various menus
• XAPI 2.01J – fixed problem of firmware upgrade from the configuration tool, over
port 1234
• PPP – significantly improved uplink data rate over UMTS module
• Web interface - improved response time
• Ring Groups - VoIP phones (extensions) could be rang together
• new default password of Admin is 2n
• DNS – fixed problem of cyclical rebooting of Ethernet module – It happened if DNS
proxy was enabled and DNS servers haven’t been set
• SIP - header Diversion
• Fixed the problem with Sierra module – if RING has come during SMS sending, SMS was
treated as not sent
• Voicemail – warning about almost filled up message space
OFR/VB3/VBE-2-3-2 2009-11-04
• DISA message – new settings – fall to the default operator, maximal duration of
the voice mail message, improved voice quality of messages
• Listen port displayed in the SIP lines menu
•